4.8.
PrIMIng The gun
4.8.1.
Before loading the gun with a cartridge or filling via a grease bucket, it is ideal to prime the gun.
4.8.2.
to prime the gun simply pack grease into the cavity located at the entrance of the gun assembly (where the grease tube screws into
the gun) and operate the trigger, this will induce the intake of grease into the gun assembly.
4.9.
oPeraTIon
4.9.1.
to operate the gun simply push the grease outlet onto the grease nipple and operate the trigger until the desired amount of grease has
been delivered. If you encounter air pockets during operation exert force on the plunger (fig.3) and depress the Vent valve (fig 4)
while operating the trigger in short, sharp bursts until grease begins to flow from the nozzle.
4.9.2.
When greasing has finished there is still pressure in the flexible hose. Before disconnecting for the greasing point it is necessary
relieve this pressure. This is achieved by the use of the Pressure Relief valve (fig.4).
4.9.3.
When the grease gun is not in use turn the red locking button on the side of the gun to the "locK" position.
4.9.4.
to check the remaining battery power, press and hold down the led display button on the top of the grease gun. A gauge will appear
on the display, showing the percentage of battery charge left.
5. TrouBleshooTIng
condition
motor fails to run
Grease gun fails to
dispense grease.
Grease gun continues
to lose prime.
Battery fails to charge
BaTTerY reMoval (unclIP FroM handle Base )
under the Waste Batteries and Accumulators regulations 2009, Jack sealey ltd are required to inform potential purchasers of products
containing batteries (as defined within these regulations), that they are registered with Valpak's registered compliance scheme. Jack
sealey ltd's Batteries Producer registration number (BPrn) is BPrn00705.
envIronMenT ProTecTIon
recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
note: it is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
Important: no liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
sealey group, kempson Way, suffolk Business Park, Bury st edmunds, suffolk. IP32 7ar
01284 757500
© Jack sealey limited
fig.4
Possible cause
- Battery needs charging
- faulty wiring to motor
- Grease tube is out of grease.
- loss of prime.
- check valve is not functioning.
- Air may be trapped in locations
throughout the grease tube ass'y after
bulk filling.
- Grease tube follower may be binding.
- charger may not have power.
- Battery may be dead.
01284 703534
Original Language Version
corrective Action
- recharge battery
- remove battery, disassemble handle and check wiring for loose
connections
- check that the tube contains grease.
- repeat priming operation.
- remove check valve, clean and inspect the valve seat.
- empty grease tube ass'y, refill and repeat priming operation.
- replace grease tube ass'y.
- check the mains charger is providing power.
sales@sealey.co.uk
www.sealey.co.uk
cPG18V.V3 | issue 1 24/11/17