5

INSTALLATION

INSTRUCTIONS 】
Figure III
As shown above, keep
the door panel flat on
the bubble, take the
joint screws, then first
connect the control unit
case and the left door
panel with screws, and
then connect the right
door panel with the
control unit case, after
they are ready, lock the
cover of the control
unit case and then make the Walk Through metal detector erected.
6
【 PRODUCT GUIDE 】
Plug the power first, open the switch below the door panel and the switch
light shine, said external power supply good. The panel of the control unit
case will display the passing times and alarm times as Figure 1.
0000 0000
Figure 1
1. Press ENTER key 3 seconds to set Sensitivity. Then the panel shows 0000
L-90 (Figure 2). L means sensitivity, 90 means the value of sensitivity, the
scope is from 0 to 99. The bigger number the higher sensitivity. Press
Upward and Downward key to adjust the sensitivity value, after adjusting the
sensitivity value, press ENTER key to save.
0000 L-90
Figure 2
2. After setting the sensitivity, press ENTER key to save tge value of
sensitivity and enter into the interface of Frequency setting. The panel shows
0000 F-11 (Figure 3). F means Frequency, 11 means the value of Frequency,
the scope is from 1-12. Press Upward and Downward key to adjust the
frequency value, after adjusting the sensitivity value, press ENTER key to
save and exit.