LIND DECHCB-5023 Manual

LIND DECHCB-5023 Manual

Lind battery charger for dell rugged batteries

Advertisement

Quick Links

LIMITED WARRANTY

Lind Electronics, Inc. (LIND) warrants the circuit assembly portion of products
manufactured by it to be free of defects in material and workmanship for a period of
1 year from the date of purchase under normal use. During this warranty period, LIND
will, at its option, repair or replace the product at no charge for parts or labor when the
product is returned postage paid as a complete unit to LIND. Proof of purchase and a letter
explaining the problem must accompany the returned unit.
This warranty does not apply if any part of the adapter, its cables or connection jacks
have been altered, subjected to abuse, accident or misuse. This warranty excludes
incidental or consequential damage resulting from the product or the use of the
product. This warranty is in lieu of all other warranties expressed or implied and no
person is authorized to assume for LIND any other liability in conjunction with this
product. The warranty gives you, the purchaser, specific legal rights and you may have
other rights which may vary from state to state and country to country.
The LIND product you are purchasing has not been designed for, or certified for use
in, life support applications. Any such use is at your own risk. LIND ELECTRONICS,
INC. HEREBY EXPRESSLY DISCLAIMS ANY IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Lind
Electronics, Inc. will not be liable for any claims, awards, damages or other liability
arising out of the use of LIND products for life support applications whether in the
nature of direct, indirect, consequential, special or punitive damages.
For assistance call Lind Technical Support at (800) 659-5956 or email us at
techsupport@lindelectronics.com.
Lind, Lind Electronics, and the Lind Logo are trademarks of Lind Electronics, Inc. All other registered trademarks and trademark
names are the property of their respective owners.
lindelectronics.com
14850 Deveau Place
952.927.6303
Minnetonka, MN 55345
info@lindelectronics.com.com
SUPSL-F00235 0119
© 2019 LIND ELECTRONICS
LIND BATTERY CHARGER FOR
DELL RUGGED BATTERIES
The Lind Battery Charging System consists of one Master Controller and one or
more Charging Bays. It also requires power from a Dell AC power adapter to
power the system.
Each Charging Bay is for use with a particular series of Dell batteries and will not
charge a different series of batteries. Charging Bays for different types of batteries can
be connected together and used in the same system. Up to 16 Charging Bays can be
connected in one system.
The Master Controller has a sliding door on its side which will expose a power jack
to plug the Dell AC power adapter in to supply the power for the Charging Bays. The
AC adapter should be rated at 45W to 330W and may have come with your tablet/
computer or may be purchased separately. The higher the wattage rating of the AC
adapter the more batteries that may be charged at the same time. If not enough
power is available the Master Controller will determine which batteries will charge first
and what sequence the rest will charge in as other batteries finish their charging. Once
charged, a battery can be removed and another discharged battery may be inserted
into that Charging Bay.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DECHCB-5023 and is the answer not in the manual?

Questions and answers

Summary of Contents for LIND DECHCB-5023

  • Page 1 If not enough Lind, Lind Electronics, and the Lind Logo are trademarks of Lind Electronics, Inc. All other registered trademarks and trademark power is available the Master Controller will determine which batteries will charge first names are the property of their respective owners.
  • Page 2 PREPARATION – Four quick amber blinks followed by 4 quick green blinks = Temporary battery fault. Charging stopped if started. May resume if fault goes away. If fault persists for more WARNING! – Remove power to the system before assembling or disassembling the than 30 seconds fault indication changes to battery failure indicated above.
  • Page 3 OPERATION ASSEMBLY Once the system is powered up and ready for use, the batteries can be inserted into the To assemble the Charging Bays together, push up against previous module and slide Charging Bays. Insert the batteries into the bays in the order you would like them to be down to connect (see diagram below).
  • Page 4 DISASSEMBLY MECHANICAL STEP 1: Unplug the Dell AC power adapter from the Master Controller and remove all batteries from the Charging Bays. Turn the Charging System over so its bottom is facing up. Push the two locking fingers of the End Cap away from the Charging Bay it is attached to while also applying a slight downward pressure to these fingers until the End Cap disengages and slides partially off the Charging Bay.

This manual is also suitable for:

Dechmc-5021Dechcb-5022

Table of Contents