WARNING
Carefully read these instructions before use.
The towel warmer is designed for fixed installation 230
V AC 50 Hz and should be installed by a qualified Class I,
must be protectively earthed.
Technical date: See type plate.
According to standard EN 60335, the following shall be
considered: This appliance can be used by children aged
from 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given
supervision or instruction concerning use of the
appliance in a safe way and understand the hazards
involved. Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by
children without supervision.
-
Always isolate the product from the electric
power supply before starting any installation
work.
-
The towel warmer´s lowest horizontal rung
should have a distance of at least 600 mm to
the floor.
-
Towel warmer reaches a temperature of
about 60°C.
-
If the main cable with plug is damaged, the
qualified person must replace the cable.
INSTALLATION
1. Follow Figures 1, 2, 3 and 4 to mount and align
the towel warmer.
Use the lower part (Fig. 1:1) as a drilling template
for the connection housing, then measure out
where the other 3 wall brackets to be placed,
Figure 1:2 – 1:5. Never drill holes in the wall
without first checking the dimensions of the unit
in question. There may be minor dimensional
differences.
Seal the screw holes using silicon or other
suitable sealing compound to prevent damp from
penetrating into the wall.
2. Pull power wiring from the wall through gland
blushing (4:1) on the connector housing and
screw the connector housing to the wall. Seal the
hole on the bottom of the connector housing
with attached cover and nut (4:2). Hang the towel
warmer into place, securing the three wall
mounts with attached screws (4:3).
Power supply 230V AC 50 Hz
Electrical connection must be performed by a
qualified technician.
1. Connect the towel warmer as shown in Figure 5,
use the enclosed terminal block with associated
junction box (the towel warmer must be
grounded). Screw the box cover Figure 6:1 and
place the junction box. Finally mount the cover
for the connection housing, Figure 7:1. Make sure
no electrical wires get pinched.
2. The main switch ON and OFF is placed in the
gable of the tube, see Figure 7:2.