Model PUS400G
Ultrasonic Oscillator
IM 19C1B3-01E
IM 19C1B3-01E
7th Edition

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PUS400G and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for YOKOGAWA PUS400G

  • Page 1 User’s Manual Model PUS400G Ultrasonic Oscillator IM 19C1B3-01E IM 19C1B3-01E 7th Edition...
  • Page 2: Introduction

    Ultrasonic cleaning has clean- ing effect on most of pollutive components. Water quality meters mean pH or ORP meter. The PUS400G ultrasonic oscillator is an apparatus for supplying an ultrasonic vibrator, built in a water quality meter, with high-frequency energy.
  • Page 3: For The Safe Use Of This Equipment

    Warning and Disclaimer The product is provided on an “as is” basis. YOKOGAWA shall have neither liability nor responsibility to any person or entity with respect to any direct or indirect loss or damage arising from using the product or any defect of the product that YOKOGAWA can not predict in advance.
  • Page 4 <INTRODUCTION> Symbol Marks Throughout this user’s manual, you will find several different types of symbols are used to identify dif- ferent sections of text. This section describes these icons. WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
  • Page 5: After-Sales Warranty

    If we replace the product with a new one, we won’t provide you with a repair report. l Yokogawa warrants the product for the period stated in the pre-purchase quotation Yokogawa shall conduct defined warranty service based on its standard. When the customer site is located outside of the service area, a fee for dispatching the maintenance engineer will be charged to the customer.
  • Page 6: Table Of Contents

    <CONTENTS> Model PUS400G Ultrasonic Oscillator IM 19C1B3-01E 7th Edition CONTENTS  INTRODUCTION ....................i  For the safe use of this equipment ..............ii  After-sales Warranty ..................iv Overview ....................1-1 Standard Specifications ................... 1-1 Model and Suffix Codes ................... 1-2 External Dimensions ..................1-3 Installation and Wiring ................
  • Page 7 <CONTENTS> 5.1.1 Troubles and Possible Causes ............5-1 5.1.2 Remedy for Supply Voltage Drop ............5-1 Part Replacing Procedure ................5-2 5.2.1 Replacing Ultrasonic Vibrator Cable ..........5-2 5.2.2 Inspecting and Replacing Procedures for Ultrasonic Vibrator ..5-2 5.2.3 Inspection of and Repair to Ultrasonic Oscillator ......5-2 Customer Maintenance Parts List ........CMPL 19C01B03-01E Revision Information ....................i IM 19C1B3-01E...
  • Page 8: Overview

    (vibrator). The PUS400G supplies the ultrasonic vibrator with operating power via a cable. The ultrasonic vibrator to be combined with the PUS400G is a vibrator mode of lead zirconate- titanate-based piezoelectric ceramics. The ultrasonic vibrator is built in the sensor holder of the pH meter.
  • Page 9: Model And Suffix Codes

    Approx. 2.0 kg Pipe mounting bracket; Approx. 0.7 kg Wall mounting bracket; Approx. 0.4 kg Noise filter assembly: (only for PUS400G-NN-KC) Ambient temperature: -10 to 50°C (no dew condensation allowed) Strage temperature: -25 to 70°C Construction: JIS C 0920 Watertight (IP53)
  • Page 10: External Dimensions

    < 1. Overview > External Dimensions Unit : mm Hood (optional) Power supply cable inlet port with cable gland (Pg16 or equivalent) Ground terminal : M4 screw 2-M5 screws (for mounting bracket) Ultrasonic transducer cable inlet port, with cable gland (Pg16 or equivalent) Weight : Approx.
  • Page 11 ±0.2 2-Ø6.6 holes (for oscillator) ±0.2 3-Ø10 holes Weight: Approx. 0.4 kg Noise filter assembly (only for PUS400G-NN-KC) Unit: mm 4-M5 screws, (depth:10mm) (for mounting) External power cable inlet (cable OD of Ø6 to Ø12) Dedicated power cable for noise filter assembly...
  • Page 12 < 1. Overview > • Pipe Mounting Bracket for Noise filter assembly (option code: /PS) Unit: mm 4-M5 screws 5- Ø6.5 holes Ø6.5 x 13 hole Pipe mounting bracket 1 2- Ø5.5 holes U-bolt Pipe mounting bracket 2 2-Ø9 holes M8 nut ×2 4-Ø10 holes (10)
  • Page 13 Blank Page...
  • Page 14: Installation And Wiring

    The PUS400G must be installed in a place where a humidity of 5 to 90% HR is maintained. Avoid installing the ultrasonic oscillator in a place where a high or low humidity is maintained for a long time. It is recommended to always operate the PUS400G at a humidity of 25 to 85% RH. •...
  • Page 15: Installing Procedure

    Hardware corresponding to the type of mounting used is required to install the PUS400G. Mounting hardware is attached only when requested. In the case of PUS400G-NN-KC (for Korea), a noise filter assembly is attached. Please refer to a figure of external dimensions for the attachment means of the noise filter assembly.
  • Page 16 < 2. Installation and Wiring > Pipe Mounting When mounting the PUS400G on a pipe, install a pipe (2-inch, OD: 60.5 mm) in the vertical or horizontal direction. Figure 2.4 illustrates the installing procedure for the ultrasonic oscillator using pipe mounting bracket.
  • Page 17: Wiring

    < 2. Installation and Wiring > Wiring This section describes types of wiring installed for the PUS400G ultrasonic oscillator and wiring work procedures type by type. 2.2.1 Types of Wiring There are three types of wiring installed for the PUS400G ultrasonic oscillator. The ultrasonic vibrator cable (of a specified length) is attached to the sensor holder of the pH meter.
  • Page 18: Connecting Ultrasonic Vibrator Cable

    With this switch provided, safety is ensured when the wires are removed from the ultrasonic oscillator for repair or the like. Use the power switch inside the PUS400G ultrasonic oscillator to start or stop it for or during steady state operation.
  • Page 19 Blank Page...
  • Page 20: Operation

    < 4. Operation > Operation The PUS400G ultrasonic oscillator should be actuated when the pH meter is operated. This chapter describes inspections before starting operation and operating procedure. Names and Function of Each Part You can see the in-action pilot lamp through the window in the front cover. When you remove the front cover, you can find the power switch, fuses and so on.
  • Page 21: Preparation For Operation

    3.3.2 Stopping and Restarting Operation For the prevention of trouble in the PUS400G ultrasonic oscillator and the ultrasonic vibrator, it is important to avoid operating the ultrasonic vibrator with no load (i.e. NOT in contact with measurement fluid.) When performing maintenance work (standard solution calibration, etc.) on the pH meter, turn OFF the power switch in the ultrasonic oscillator and then pull the ultrasonic vibrator out of measurement fluid.
  • Page 22: Inspection And Maintenance

    < 4. Inspection and Maintenance > Inspection and Maintenance This chapter describes routine inspection and maintenance work required to allow the PUS400G ultrasonic oscillator to fully deliver its performance and to obtain favorable cleaning results. Refer to “5. Troubleshooting” in this manual for the improvements of the equipment preventing the achievement unfavorable cleaning effect and the remedies for troubles in the equipment.
  • Page 23: Inspection When In-Action Pilot Lamp Is Off

    Referring to the user’s manual for the pH meter, examine the power supply circuit for the ultrasonic vibrator in the holder. If the cause of the in-action pilot lamp going out cannot be identified even after checking all the above-mentioned items, contact YOKOGAWA. 4.2.2 Replacing Procedure for Fuse (Check to see that the power switch is OFF before proceeding with the procedure.)
  • Page 24: Troubleshooting

    This chapter describes remedies for malfunctions of the ultrasonic oscillator. Caution against Electric Shock Some areas in the electric circuits in the PUS400G ultrasonic oscillator remain carrying high voltage for a while (approx. 10 minutes) even after the power switch is turned OFF.
  • Page 25: Part Replacing Procedure

    Inspection of and Repair to Ultrasonic Oscillator The operational inspection of, and repair to, the ultrasonic oscillator call for a thorough knowledge of its electric circuits and the skill of repairing. If the ultrasonic oscillator malfunctions, request inspection or repair from YOKOGAWA. IM 19C1B3-01E...
  • Page 26: Customer Maintenance Parts List

    Pan H. Screw, M5 20 Y9500WU Washer Y9102XA O-ring K9311JN Window Assembly CMPL 19C01B03-01E All Rights Reserved, Copyright © 1997, Yokogawa Electric Corporation. Subject to change without notice. 1st Edition : Feb. 1997 (YK) Yokogawa Electric Corporation 5th Edition : Jul. 2009 (YK)
  • Page 27 Fuse (1 A) L9811FK L9811FT Cable Gland Adapter Assembly K9317AF (For G1/2 screw; option code : /AFTG) K9317AG (For 1/2NPT screw; option code : /ANSI) CMPL 19C01B03-01E All Rights Reserved, Copyright © 1997, Yokogawa Electric Corporation. 5th Edition : Jul. 2009 (YK)
  • Page 28 K9311KG for /H option K9660JA for /H2 option K9317AY Pipe Mounting Bracket Assembly K9149SB Wall Mounting Bracket Assembly K9311KA Panel Mounting Bracket Assembly CMPL 19C01B03-01E 5th Edition : Jul. 2009 (YK) All Rights Reserved, Copyright © 1997, Yokogawa Electric Corporation.
  • Page 30: Revision Information

    Revision Information Title : Model PUS400G Ultrasonic Oscillator Manual No. : IM 19C1B3-01E Mar. 2018/7th Edition Addition of RCM (p. 1-2) Revised a description of -KC (p.1-2) Mar. 2014/6th Edition Addition of "For Korea (-KC)" 1.1 Addition of specifications, 1.2 Addition of Suffix Code, 1.3 Addition of the Noise filter assembly, 2.1.2 &...
  • Page 31 Blank Page...