COMPLIANCE ......................1 FDA-CDRH Compliance ..........................1 CSA / IEC Compliance ..........................1 CE Compliance ............................1 GENERAL INFORMATION .................... 2 OA1 Optical Attenuator Overview ......................2 Applications ............................... 2 Key Features .............................. 2 Included Accessories ..........................3 SAFETY INFORMATION ....................4 Safety Markings on the Unit ........................
Page 4
Note................................. 20 Commands Lists............................20 MAINTENANCE ......................23 Cleaning the Unit ............................. 23 Cleaning the Output ..........................23 Cleaning Jumper Connectors ........................25 STORAGE AND SHIPPING ..................26 Returning Instruments to JGR Optics ...................... 26 Contact Information ..........................26 SPECIFICATIONS ......................27 M-OA1-001-01...
OA1 User Manual COMPLIANCE FDA-CDRH Compliance Under the US Food and Drug Administration (FDA) Center for Devices and Radiological Health (CDRH), the unit complies with the Code of Federal Regulations (CFR), Title 21, Subchapter J, which pertains to laser safety and labeling. See following link for more information: •...
BER testing of transmitters and receivers, and channel equalization in WDM systems. The OA1 Optical Attenuator is available for single-mode and multimode fibers and can be configured for various wavelength ranges and input power levels. Figure 1: OA1 Optical Attenuator Applications •...
OA1 User Manual • Customizable • Touchscreen display • USB/Ethernet control Included Accessories • USB A to USB B cable (1.8m) • Ethernet cable (1.8m) • AC power cord (2m) M-OA1-001-01...
Ensure that all conditions necessary for safe handling and operation are met before proceeding. Classification The OA1 consists of an exposed metal chassis that is connected directly to earth via a power cord and is therefore classified as a Class 1 instrument. M-OA1-001-01...
OA1 User Manual Important Safety Information Laser Hazards Warning • Never look directly into the end of an optical cable connected to an optical output device that is operating. Laser radiation is invisible and direct exposure can severely injure the human eye.
Page 11
If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. Only technicians authorized by JGR Optics Inc. should carry out repairs. In addition to voiding the warranty, opening the unit (even when unplugged) can expose you to potential shock hazards.
INFORMATION on page 4. This manual contains complete operating instructions for safe and effective operation of the OA1 Optical Attenuator. It is recommended that users of the OA1 familiarize themselves with contents of this manual before using the instrument. The inspection report and a description of any customer-requested information may be found in the calibration document envelope included with the instrument.
± 10% of the nominal voltage Product Overview OA1 Front Panel A front view of the OA1 attenuator is show in Figure 2. The standard front panel bulkhead types are FC or Figure 2: Front view of the OA1 Optical Attenuator OA1 Rear Panel A rear view of the OA1 attenuator is shown in Figure 3.
Page 14
OA1 User Manual Figure 3: Rear view of an OA1 Table 3: Detailed description of the OA1 rear panel components (see Figure 3) Item # Description LAN/Reset • Press once: reset network settings Ethernet port • Connection to LAN USB B port •...
Press to select wavelength change wavelength Figure 4: Front panel operation – setting the wavelength The OA1 has 4 stored wavelength settings. Pressing the λ button a second time will display the flyout to select the wavelength “slot” (Figure 5). M-OA1-001-01...
OA1 User Manual Figure 5: Front panel operation – wavelength flyout menu Setting the Attenuation Press the Att. button to set the attenuation (Figure 6). Use arrows to Press to set the attenuation change attenuation Figure 6: Front panel operation – setting the attenuation...
OA1 User Manual Press and hold on the screen to set the attenuation to 0 dB. Press and hold a second time to go to the minimum IL point. ∞ Pressing the button will engage the beam block shutter (> 100 dB attenuation).
Displays the PN of the unit. • If connected to a network via Ethernet, it will show the IP address of the unit. Use this IP address to access the OA1 webpage or connect to it via software. • If not connected to a network, it will show as N/A.
OA1 User Manual OA1 WEBPAGE To access the OA1 webpage, connect the attenuator to a network and on any computer or tablet on the same network, open a web browser (recommended: Google Chrome) and enter the OA1’s IP address in the URL bar.
Settings Click on the Settings tab to expand. Network Settings You can view, edit or reset the network settings of the OA1 from the Settings > Network Settings tab (Figure 11). Figure 11: OA1 webpage – Network Settings tab M-OA1-001-01...
OA1 User Manual Upgrade Go to Settings > Upgrade to view the version of, upgrade or re-install the firmware of the OA1 (Figure 12). Please contact support@jgroptics.com before performing a firmware upgrade for additional instructions. Figure 12: OA1 webpage – Upgrade tab...
Click on the Help tab for the website technical support and sales contact forms as well as a link to the software downloads page. Alternatively, email support@jgroptics.com for technical support or info@jgroptics.com for sales and other inquiries. Figure 13: OA1 webpage – Help tab M-OA1-001-01...
OA1 User Manual About The About tab displays the unit’s firmware version, model and serial number. Advanced mode is reserved for JGR technicians and JGR-approved service centers. Figure 14: OA1 webpage – About tab M-OA1-001-01...
The OA1 follows the SCPI (Standard Commands for Programmable Instruments) message-based programming standard. It conforms to the USBTMC (USB Test and Measurement) standard. The TCP/IP libraries provided by most operating systems are sufficient. JGR Optics can provide a communications library upon request.
End Sub Write commands require termination with the linefeed character \n. Note The OA1 runs SCPI commands synchronously. An *OPC? Command can be sent and a 1 will be returned when all operations have been completed: Commands Lists See Table 5 and Table 6 for SCPI required and OA1 commands respectively.
Page 26
:SYSTem:COMMunicate:LAN:GATEway? :SYSTem:COMMunicate:LAN:MASK <netmask> :SYSTem:COMMunicate:LAN:MASK? :SYSTem:COMMunicate:LAN:HOSTname <hostname> :SYSTem:COMMunicate:LAN:HOSTname? :SYSTem:COMMunicate:LAN:MAC? Note: for a single module OA1, omit [n] in the commands below. Table 6: OA1 commands list Command Description INput[n]:ATTenuation # Attenuates <#> dB on module <n>. INput:ATTenuation:ALL # Attenuates <#> db on all modules that support it. If any modules don’t support this, returns an error.
Page 27
OA1 User Manual OUTput[n]:DRIFT # Sets the drift tolerance <#> in dB for the power levelling. Default value is 0.1 dB, must be greater than 0. OUTput[n]:POW:MON? Returns the current internal PD reading (no offsets). OUTput[n]:DARK Measures and stores the dark current on the PD. The beam block will engage if necessary.
3. Do not plug the unit back in until it is completely dry. Cleaning the Output Warning • Connecting contaminated or damaged connectors to the OA1 can damage the unit and affect its performance. • Damaging the output fiber during maintenance can affect the performance of the unit.
Page 29
JGR's CS400K Figure 17: Exposed view of good output fiber Figure 18: Exposed view of poor output fiber management management Note: the exposed views are only for instructional purposes. The OA1 chassis should not be opened during normal maintenance. M-OA1-001-01...
Optical cable ends need to be inspected before each mating to ensure they are free of contamination or damage. An inspection scope such as JGR’s CS400K is required. If they are contaminated, they must be cleaned. The following items are required.
As indicated above, please ship the returned material in the original shipping box and packing material. If these are not available, follow the guidelines below: 1. Contact JGR Optics to obtain an RMA number. 2. Cover the front panel with foam to prevent damage.
Need help?
Do you have a question about the OA1 and is the answer not in the manual?
Questions and answers