SaniJura ZEPHYR Instructions For Installation And Use Manual

Heating column

Advertisement

Quick Links

ZEPHYR
INSTRUCTION FOR INSTALLATION
AND USE - GARANTY
You have just acquired this heating column ZEPHYR
And we thank you for your choice.
This device has been studied, designed and realized with care,
In order to give you full satisfaction.
1770002 - Notice - ZEPHYR_Rev 01
This product cannot be used as main heater

Advertisement

Table of Contents
loading

Summary of Contents for SaniJura ZEPHYR

  • Page 1 ZEPHYR INSTRUCTION FOR INSTALLATION AND USE - GARANTY You have just acquired this heating column ZEPHYR And we thank you for your choice. This device has been studied, designed and realized with care, In order to give you full satisfaction.
  • Page 2: Table Of Contents

    Hanging ZEPHYR on the wall ........
  • Page 3: Markings & Indications

    At minimal thermal power C el min In Sleep Mode C el veil ZEPHYR DECORATED GLASS 175 x 40 reference : 10 2041 / 10 2043 / 10 2045 / 10 2040 / 10 2042 / 10 2044 THERMAL POWER Nominal thermal power...
  • Page 4: General Instruction

    (cable type H05VV - F 2 * 1 mm²). The system complies with current standards (see technical data). The heating column ZEPHYR is only suitable for indoor use. It is suitable for all the rooms of the housing, including bathrooms thanks to a suitable protection (Double...
  • Page 5 The heater should not be placed directly below a power outlet. Thoroughly test the radiator before installation and ensure that no hot spots develop. Only use the heating column ZEPHYR for the recommended applications and with the ZEPHYR accessories offered (bars, regulation) for an effective guarantee.
  • Page 6: Precautions For Use

    Do not cover the heating facade to ensure radiation efficiency and avoid accidental overheating. Cut off the heating column ZEPHYR with the switch and wait for it to cool down to clean it with a soft, damp cloth. Do not let a child unattended take care of it.
  • Page 7: Instruction For Installation Of Zephyr

    Installation of heating column ZEPHYR These instructions aim at easing the furniture assembly, they are not legaly- binding. The srews and dowels choices as well as the wall drilling method for mural fixations depend on your wall quality and composition, and thus depend on...
  • Page 8: Composition

    Equipment description and references: facades item code : 102020, 102021, 102022 102030, 102031, 102032 towel rail left column item right column item 102040, 102041, 102042 item code : code: code: 102043, 102044, 102045 924102 102009, 102011 102010, 102012 Wall Electrical output position : 40 cm 220-240V 175 cm...
  • Page 9: Facade Assembly

    Heating facade assembly and adjustments : Preparation work before hanging on the wall: 40 cm 6 cm 2 cm 2 cm 175 cm Cl II IP X4 Pilot Wire See P 20 cm...
  • Page 10: Hanging Zephyr On The Wall

    Column hanging & wire passing : 5 cm mini Shelves assembly :...
  • Page 11: Towel Rails Assembly

    Towel rail assembly : 1 or 2 towel rails :...
  • Page 12: Electrical Connection

    • Electrical connexion Connect electrically. L = Phase (brown) N = Neutral (blue) The electrical connexion must be made with a IPx4 box , class II, in compliance with regulation. PILOT WIRE = FP (noir) Do not plug in if you are not connected to an automated system that manages the Pilot wire.
  • Page 13: Operation Of The Programmable Wireless Thermostat

    Operation of the programmable wireless thermostat The heating column is managed by an autonomous radio frequency regulation system. It is composed of 2 elements ; the thermosthat and the reciever located inside the facade. The carton includes : The wireless thermostat 2 batteries AAA 2 feet for free installation of the thermostat 1 Connector board et 4 screws for wall mounting...
  • Page 14: Basic Parameters

    Basic parameters Hours setting Press ‘SET’ until the minutes flash. Change using the ‘+’ and ‘-’ keys. Press ‘SET’ a second time to change the flashing times using the ‘+’ and ‘-’ keys. If you are done, you will return automatically to the first screen. Set the day of the week Press ‘SET’...
  • Page 15: Pairing Instructions

    Thermostat pairing Consists in creating the radio link between a thermostat and the receiver located in the column. Note : it is possible to control up to 5 columns with only one thermostat. The thermostat setting will be the same for all linked columns. Operating principles 17°C 22°C...
  • Page 16 Thermostat pairing steps Switch on position 1 Press 3 to 5 s until screen shuts down Press again until screen lights on, then release immediately. Browse to menu by pressing 3 times on Press on the column pairing button Press + on the thermostat... with a pen edge...
  • Page 17: Mode Selection

    Available control programms Comfort mode keeps a «confort» temperature 24/24 - 7/7. Economy mode keeps an «ECO» temperature 24/24 - 7/7. Holiday mode keeps a lower temperature in case you leave your home for a long period. Programmable mode allows to heat only according your needs to ensure real energy savings.
  • Page 18: Programmable Mode

    Programmable mode Prerequisite : basic parameter set up must be already done (date, hour...). The user programm allows to alternate heating hours in COMFORT MODE with heating hours in ECONOMY MODE , to adapt itself at best to the hours you are at home.
  • Page 19 Press + as many times as many ... For this example you have validated hours needed in ECO mode ... 0:00 to 5:59 in ECO mode (not heated) Press SET to go to Press + as many times as many COMFORT mode hours needed in COMFORT mode (ex: 6:00 to 8:59)
  • Page 20: Secondary Functions

    Secondary functions Menu N° DESCRIPTION TEMP VALuE RANGE Thermostat temperature sensor calibration If Needed -8/+8°C 0°C Maximal possible temperature for setting setpoint If Needed <35°C 35°C temperature Minimal possible temperature for setting setpoint If Needed >5°C 5°C temperature Thermostat pairing / column – see dedicated previous Mandatory pages Sensitivity setting in temperature lowering for opening...
  • Page 21 MENU 1 : Temperature sensor calibration If the temperature indicated on the thermostat do not correspond to the room real temperature, it is possible to adjust the display : Just like in the pairing steps, press until the screen shuts down, release and press again until the screen lights up : you are in menu 1.
  • Page 22 Opening detection set up steps : Press until the screen shuts down, release and press again until the screen lights up again. Reach menu 5 by pressing 4 x Adjust lowering temperature difference (when a window is open) Press SET to go to menu 6. Ajuster increasing temperature difference to end function.
  • Page 23 MENU 9 : Time anticipation As anticipation is key to confort and savings, the thermostat learns and manages for you optimal starting time for an immediate and instant comfort where you wish. Without Anticipation Without Anticipation Overheat due to conventional Overheat due to conventional thermostat: thermostat:...
  • Page 24 If the room temperature cannot reach the setpoint temperature set up in less than 60 minutes, then the thermostat will trigger the heat automatically. The heat «icon» will then be blinking. By pressing + on the setpoint temperature adjustment screen, SET will be blinking and the setpoint temperature will automatically be set at 35°...
  • Page 25 MENU 8 : Piloting through a Centralised Building Technical Management (GTB) with Pilot Wire function help PILOT WIRE function allows you to pilot all your colums through a standard centralised management. COMFORT NO SIGNAL ECO or HOLIDAYS 230V Normal signal uNFROZEN HALF NEGATIVE SIGNAL STOP...
  • Page 26: Technical Characteristics Of Zephyr

    Technical characteristics of ZEPHYR heating column Voltage: ~230V/AC (50/60Hz) Maximal Intensity per heating colum : 5A Protection Class : Protection Index : IP44 Indicated power per room : 54W/m² Conformity: CEI60335-1, CEI60335-2-30, CEI60335-2-43 et EN50014-1, EN50014-2, EN61000-3-2, EN61000-3-3 EMERALD RANGE TO DISCOVER www.sanijura.fr...
  • Page 27: Diagnostic Help

    Help with diagnosis NATuRE OF THE PROBLEM CONTROL ACTION 1. Ensure that the green light is Turn the function button lighting (power) and the red light (The switch on the side is lighting too of device) to position I or II 2.
  • Page 28: Guarantee Terms

    Guarantee • 5 years for the heating element of the heating column ZEPHYR and 2 years for the Programmable electronic thermostat. • The warranty period starts from the date of purchase on the Invoice or receipt. • This warranty applies in addition to all standard laws.
  • Page 29: Guarantee Certificate

    Name: Email : Street : Product : ZIP code: Date of purchase : City : Installater : Country : Date of installation : Tel. : Please attach a copy of the purchase invoice. SANIJuRA, 33 rue Stephen Pichon, 39302 CHAMPAGNOLE...

Table of Contents