7. SPECIAL FUNCTIONS

7.1 DEFAULT IP ADDRESS

In case of unknown IP, it is possible to come back to the default one (192.168.1.234) by following
the next steps:
Turn off the unit.
Connect contact inputs 5, 6, 7 and 8 to GND.
Turn on the unit.
Wait for the Ready indicator to blink light yellow.
Disconnect all contact inputs.
Wait for the Ready indicator to light yellow.
Access the unit from the web browser, using the default IP, and follow the steps of
paragraph 4.2 to change it.
Restart the unit.
Note: The default IP address is temporary. Once the unit is restarted again, it will come back to the
IP configured in the web server.
SMM-8SA v2.0
SMM-8SA
SCHEDULED MESSAGE MODULE
Image 23. Connection example to restore default IP.