  • Page 1 OE 4002 MULTIMETRE MEGOHMMETRE ET TESTEUR D’ISOLEMENT 1000V CAT. III MULTIMETER MEGOHMETRE AND INSULATION TESTER 1000V CAT. III clas.com...
  • Page 2: Consignes De Securite

    OE 4002 MULTIMETRE MEGOHMMETRE ET TESTEUR D’ISOLEMENT 1000V CAT. III CONSIGNES DE SECURITE Ce multimètre numérique a été conçu et fabriqué conformément aux normes de sécurité défi nies par les normes EN61010-1, EN61010-2-030 pour les appareils électriques d’essai. Sa conception et sa fabrication sont rigoureusement basées sur les dispositions 1000V CAT III, 600V CAT IV de la norme IEC61010-1 et de l’exigence...
  • Page 3: Garantie

    OE 4002 MULTIMETRE MEGOHMMETRE ET TESTEUR D’ISOLEMENT 1000V CAT. III GARANTIE Ce multimètre est garanti contre tout défaut de matériel et de fabrication dans des conditions normales d’utilisation et de service. La période de garantie est de un an et commence à la date d’expédition. La garantie s’applique sur une période de 12mois sauf en cas d’utilisation incorrecte, de modifi...
  • Page 4: Ecran D'affichage

    OE 4002 MULTIMETRE MEGOHMMETRE ET TESTEUR D’ISOLEMENT 1000V CAT. III ECRAN D’AFFICHAGE Voyant Description Le voyant de batterie faible indique qu’il est temps de remplacer les piles. Pour éviter toutes mesures incorrectes, qui pourraient entraîner un éventuel risque d’électrocution ou de blessure corporelle, veuillez remplacer les piles dès que le voyant de batterie faible apparaît.
  • Page 5 OE 4002 MULTIMETRE MEGOHMMETRE ET TESTEUR D’ISOLEMENT 1000V CAT. III Voyant Description Les symboles de plus grande valeur en mode d’essai d’isolation indiquent que la valeur mesurée est dépassée. En mode d’isolation, l’avertissement de tension dangereuse indique qu’une tension supérieure à 20V est détectée sur les bornes d’entrée.
  • Page 6 OE 4002 MULTIMETRE MEGOHMMETRE ET TESTEUR D’ISOLEMENT 1000V CAT. III Voyant Description Unité de mesure de la tension nominale d’origine pour l’essai d’isolation. Unité de temps de mesure de l’isolation. Indique que le multimètre fonctionne en mode d’enregistrement. Sous ce mode, le multimètre peut enregistrer les 100 dernières valeurs mesurées.
  • Page 7 OE 4002 MULTIMETRE MEGOHMMETRE ET TESTEUR D’ISOLEMENT 1000V CAT. III BOUTONS Bouton Description - Lorsque le sélecteur rotatif est sur une autre position que Isolation, appuyez sur le bouton. L’affi chage n’est pas mis à jour. - Lorsque le sélecteur rotatif est sur la position Isolation, appuyez sur le bouton pour passer en mode de verrouillage de l’essai.
  • Page 8 OE 4002 MULTIMETRE MEGOHMMETRE ET TESTEUR D’ISOLEMENT 1000V CAT. III Bouton Description Affi chage de la valeur DAR ou PI. Activation/désactivation du rétroéclairage : lorsque la lumière est allumée, le multimètre se met en mode d’arrêt de l’éclairage après 10 secondes.
  • Page 9 OE 4002 MULTIMETRE MEGOHMMETRE ET TESTEUR D’ISOLEMENT 1000V CAT. III Position Fonction La température est mesurée en Celsius. Appuyez sur le bouton Shift pour passer à la mesure de la température en Fahrenheit de -30°C à 1300°C (-22°F~2372°F) Ohms : 0.1 ~60M Capacité...
  • Page 10 OE 4002 MULTIMETRE MEGOHMMETRE ET TESTEUR D’ISOLEMENT 1000V CAT. III Description Borne Borne d’entrée positive sauf pour la mesure de courant et d’isolation. Borne commune sauf pour la mesure de l’isolation. Borne d’entrée positive pour la mesure du courant. Ne mesurez pas le courant dépassant 400mA (TRMS)
  • Page 11: Descriptif Des Fonctions

    OE 4002 MULTIMETRE MEGOHMMETRE ET TESTEUR D’ISOLEMENT 1000V CAT. III DESCRIPTIF DES FONCTIONS OPTIONS DE MISE EN MARCHE L’appui sur le bouton tout en mettant en marche le multimètre active l’option de mise en marche. Les options de mise en marche vous permettent d’utiliser d’autres fonctions du multimètre. Pour sélectionner une option de mise en marche, appuyez sur le bouton de votre choix tout en tournant le sélecteur du multimètre de la position OFF sur...
  • Page 12 OE 4002 MULTIMETRE MEGOHMMETRE ET TESTEUR D’ISOLEMENT 1000V CAT. III MESURE RELATIVE Affi che la différence entre la valeur actuelle et la base relative. Appuyez sur le bouton REL pour saisir la mesure relative et le multimètre enregistrera la valeur initiale lors de l’appui sur la touche.
  • Page 13 OE 4002 MULTIMETRE MEGOHMMETRE ET TESTEUR D’ISOLEMENT 1000V CAT. III VERROUILLAGE DE L’ESSAI D’ISOLATION En mode d’essai d’isolation, appuyez sur le bouton Test pour effectuer le test d’isolation. Appuyez sur le bouton Test pour effectuer l’essai d’isolation. Lorsque le bouton est relâché, l’écran affi che le signe Hold.
  • Page 14 OE 4002 MULTIMETRE MEGOHMMETRE ET TESTEUR D’ISOLEMENT 1000V CAT. III Appuyez sur le bouton MEM pour changer la position puis sur le bouton Shift pour modifi er la valeur. Appuyez sur le bouton HOLD pour enregistrer l’heure de la mesure et quitter l’état assigné.
  • Page 15 OE 4002 MULTIMETRE MEGOHMMETRE ET TESTEUR D’ISOLEMENT 1000V CAT. III ENREGISTREMENT DES DONNEES EN MODE MULTIMETRE Appuyez sur le bouton MEM pour saisir le mode d’enregistrement. Le multimètre affi che MEM comme indiqué ci- dessous : En mode d’enregistrement, le multimètre enregistre la valeur mesurée (lorsque l’enregistrement dépasse 100 valeurs, le multimètre enregistre uniquement les 100 dernières valeurs).
  • Page 16 OE 4002 MULTIMETRE MEGOHMMETRE ET TESTEUR D’ISOLEMENT 1000V CAT. III Lorsque le temps restant est zéro, l’écran secondaire affi che le nombre de fois où la valeur a été enregistrée comme suit Appuyez sur le bouton MEM pour que l’écran secondaire affi che le nombre séquentiel de la valeur enregistrée et pour que l’écran principal affi...
  • Page 17 OE 4002 MULTIMETRE MEGOHMMETRE ET TESTEUR D’ISOLEMENT 1000V CAT. III Lorsque le temps restant est zéro, le multimètre revient en mode d’Enregistrement. Enregistrement de données en mode d’essai d’isolation En mode d’essai d’isolation, la fonction d’enregistrement sera activée. Appuyez sur le bouton MEM pour voir la valeur enregistrée. La procédure décrite est la...
  • Page 18 OE 4002 MULTIMETRE MEGOHMMETRE ET TESTEUR D’ISOLEMENT 1000V CAT. III PRISE DE MESURE DE BASE MESURE DE LA TENSION CONTINUE Tournez le sélecteur rotatif sur la position Tournez le sélecteur rotatif sur la position , les bornes d’entrée et les câbles d’essai doivent être connectés , les bornes d’entrée et les câbles d’essai doivent être connectés...
  • Page 19: Mesure De La Tension Alternative

    OE 4002 MULTIMETRE MEGOHMMETRE ET TESTEUR D’ISOLEMENT 1000V CAT. III MESURE DE LA TENSION ALTERNATIVE...
  • Page 20 OE 4002 MULTIMETRE MEGOHMMETRE ET TESTEUR D’ISOLEMENT 1000V CAT. III Les multimètres RMS mesure précisément les distorsions. En revanche, lorsque les câbles d’essai sont en court-circuit dans les fonctions CA, le multimètre affi che un relevé résiduel entre 1 et 30 comptes de valeur. Lorsque les câbles d’essai sont ouverts, les relevés peuvent varier en fonction des interférences.
  • Page 21 OE 4002 MULTIMETRE MEGOHMMETRE ET TESTEUR D’ISOLEMENT 1000V CAT. III MESURE DE LA TEMPERATURE Le multimètre mesure la température d’un thermocouple de type K (inclus). Choisissez entre les degrés Celsius (°C) ou Fahrenheit (°F) en appuyant sur le bouton Shift.
  • Page 22 OE 4002 MULTIMETRE MEGOHMMETRE ET TESTEUR D’ISOLEMENT 1000V CAT. III MESURE DE LA RESISTANCE ET MESURE DE LA CAPACITE Pour éviter tout endommagement du multimètre ou de l’appareil testé, déconnectez l’alimentation du circuit et déchargez tous les condensateurs à haute tension avant de procéder à l’essai de continuité. Appuyez sur le bouton...
  • Page 23 OE 4002 MULTIMETRE MEGOHMMETRE ET TESTEUR D’ISOLEMENT 1000V CAT. III MESURE DE LA CONTINUITE ET MESURE DE LA DIODE L’essai de continuité et l’essai de la diode incluent un signal sonore qui retentit dès qu’un circuit a été testé. Le signal sonore retentit en présence d’une faible tension (<30 ) ou d’une tension directe inférieure à...
  • Page 24 OE 4002 MULTIMETRE MEGOHMMETRE ET TESTEUR D’ISOLEMENT 1000V CAT. III MESURE DU COURANT CONTINU OU ALTERNATIF Vérifi ez que le fusible est en bon état avant de commencer l’essai. Sélectionnez la borne d’entrée, le sélecteur rotatif et la plage adéquats afi n de ne pas mesurer le courant dépassant le taux nominal du multimètre (400mA)
  • Page 25 OE 4002 MULTIMETRE MEGOHMMETRE ET TESTEUR D’ISOLEMENT 1000V CAT. III MESURE DE LA FREQUENCE En mode de mesure de la tension de courant alternatif, appuyez sur le bouton Hz pendant plus d’une seconde. Le multimètre passe de la mesure de la tension au mode de mesure de fréquence. Le bouton Range n’est plus disponible.
  • Page 26 OE 4002 MULTIMETRE MEGOHMMETRE ET TESTEUR D’ISOLEMENT 1000V CAT. III ESSAI D’ISOLATION Les essais d’isolation doivent uniquement être effectués sur des circuits non alimentés. Vérifi ez le fusible et les câbles d’essai avant d’effectuer l’essai. Tournez le sélecteur rotatif en position d’Isolation. Si le multimètre affi che Tournez le sélecteur rotatif en position d’Isolation.
  • Page 27 OE 4002 MULTIMETRE MEGOHMMETRE ET TESTEUR D’ISOLEMENT 1000V CAT. III...
  • Page 28: Caracteristiques Generales

    OE 4002 MULTIMETRE MEGOHMMETRE ET TESTEUR D’ISOLEMENT 1000V CAT. III CARACTERISTIQUES GENERALES Conforme à la norme IEC/EN 61010-1 1000V CAT III, 600V CAT IV. Tension CC 1000V, Tension CA 750V (TRMS). 6600 comptes (sauf pour la mesure de capacité, de température et d’isolation) Lorsque les bornes d’entrée sont V et COM, la surcharge de tension de protection s’élève jusqu’à...
  • Page 29: Tension Alternative

    OE 4002 MULTIMETRE MEGOHMMETRE ET TESTEUR D’ISOLEMENT 1000V CAT. III PRECISION TENSION CONTINUE Plage Résolution Précision 660mV 0.1mV 0.1mV 6.6V ±(0.5%+5) 10mV ±(0.5%+5) 660V 100mV ±(0.5%+5) 1000V ±(0.5%+5) TENSION ALTERNATIVE Plage Résolution Précision 660mV 0.1mV - - - - - - 6.6V...
  • Page 30: Courant Alternatif

    OE 4002 MULTIMETRE MEGOHMMETRE ET TESTEUR D’ISOLEMENT 1000V CAT. III RESISTANCE Plage Résolution Précision ±(1.2%+5) 6.6K ±(1.2%+5) ±(1.2%+5) 660K ±(1.2%+5) 6.6M ±(2.0%+20) ±(2.0%+20) CAPACITANCE Plage Résolution Précision 66nF 10pF ±(5.0%+20) 660nF 0.1nF ±(5.0%+20) 6.6 F ±(5.0%+20) 66 F 10nF ±(5.0%+20) 660 F 0.1 F...
  • Page 31 OE 4002 MULTIMETRE MEGOHMMETRE ET TESTEUR D’ISOLEMENT 1000V CAT. III FREQUENCE Plage Résolution Précision 660.0Hz 0.1Hz ±(1.5%+5) 6.600Hz ±(1.5%+5) 66.00Hz 10mV ±(1.5%+5) >10kHz - - - - - - - ISOLATION Tension de Affi chage de Résolution Précision 0~5M 0.01M ±(3%+5)
  • Page 32 OE 4002 MULTIMETRE MEGOHMMETRE ET TESTEUR D’ISOLEMENT 1000V CAT. III ACCESSOIRES Pièce Quantité Câbles d’essai Clips Thermocouple de type K Pile AA LR6 Manuel Prise multifonctions...
  • Page 33: Security Warning

    OE 4002 MULTIMETER MEGOHMETRE AND INSULATION TESTER 1000V CAT. III SECURITY WARNING This style of digital multimeter is designed and manufactured according to the safety requirements set out by EN61010-1, EN61010-2-030 standards for electronic test instruments. Its design and manufacture is strictly based on the provisions in the 1000V CAT III, 600V CAT IV of IEC61010-1 and the Stipulation of 2-Pollution Grade.
  • Page 34: Warranty

    OE 4002 MULTIMETER MEGOHMETRE AND INSULATION TESTER 1000V CAT. III WARRANTY The meter is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is one year and begins on the date of shipment. Parts, product repairs, and services are warranted for 18 months except for misused, altered, neglected, contaminated, or damaged by accident or abnormal conditions of operation or handling.This warranty does not apply to fuses, disposable batteries.
  • Page 35: Display Screen

    OE 4002 MULTIMETER MEGOHMETRE AND INSULATION TESTER 1000V CAT. III DISPLAY SCREEN Indicator Description Low battery Indicates when it is time to replace the battery. To avoid false rea- dings, which could lead to possible electric shock or personal injury, replace the battery as soon as the low battery indicator appears.
  • Page 36 OE 4002 MULTIMETER MEGOHMETRE AND INSULATION TESTER 1000V CAT. III Indicator Description Greater symbols, In insulation test mode, indicates the measure value over- fl ow. Unsafe voltage warning, In insulation mode, indicates greater 20V voltage is detected on the input terminals.
  • Page 37: Display Messages

    OE 4002 MULTIMETER MEGOHMETRE AND INSULATION TESTER 1000V CAT. III Indicator Description The measuring uint of source voltage rating for insulation test. Insulation Measuring time Unit. Auxiliary Display :display the output voltage, time. Primary Display: display the measure value. DISPLAY MESSAGES...
  • Page 38 OE 4002 MULTIMETER MEGOHMETRE AND INSULATION TESTER 1000V CAT. III BUTTONS Bouton Description - When rotary switch at the position except insulation, press the button, the display not updated. - When rotary switch at the insulation position, press the button toggle the test lock.
  • Page 39: Rotary Switch

    OE 4002 MULTIMETER MEGOHMETRE AND INSULATION TESTER 1000V CAT. III Bouton Description Display DAR or PI Value. Back Light on/Off,when the light turn on ,after 10S the meter auto turn off light. When rotary switch at the insulation position, press the button to perform insu- lation test.
  • Page 40: Input Terminal

    OE 4002 MULTIMETER MEGOHMETRE AND INSULATION TESTER 1000V CAT. III Position Fonction Celsius is the default temperature measurement unit press shift button switch to Fahrenheit measurement unit Temperature from-30°C to1300°C (-22°F~2372°F) Ohms : 0.1 ~60M Capacitance: 0.01nF~60mF Continuity Diode DC Current (0.01mA~400mA) AC Current (3.00mA~400mA)
  • Page 41 OE 4002 MULTIMETER MEGOHMETRE AND INSULATION TESTER 1000V CAT. III Description Borne Input positive terminal except current and inuslation measure. Common terminal except Inuslation measure. Input positive terminal for current measure,do not measure any current exceed 400mA (TRMS). Input positive terminal for Insulation measure.
  • Page 42: Function Description

    OE 4002 MULTIMETER MEGOHMETRE AND INSULATION TESTER 1000V CAT. III FUNCTION DESCRIPTION POWER-UP OPTION Holding a button down while turning the Meter on activates a power-up option. Power-up options allow you to use additional features and functions of the Meter. To select a power-up option, hold down the appropriate button indicated while turning the Meter from OFF to any switch position.
  • Page 43: Relative Measurement

    OE 4002 MULTIMETER MEGOHMETRE AND INSULATION TESTER 1000V CAT. III RELATIVE MEASUREMENT Show the difference between actual value and the relative base. Press REL Button to enter relative measurement and the meter will record the initial value when pressing the key.
  • Page 44: Insulation Test Lock

    OE 4002 MULTIMETER MEGOHMETRE AND INSULATION TESTER 1000V CAT. III INSULATION TEST LOCK In insulation test mode, press Test button to perform insulation test until the button is released.when the button is released,the screen display hold sign. Press Lock Button ,then the screen display Lock sign, press Test Button ,the meter will perform insulation test unitl you press Test button again;The test lock will unlocked while to cancel insulation test.
  • Page 45 OE 4002 MULTIMETER MEGOHMETRE AND INSULATION TESTER 1000V CAT. III Press MEM button to change positon, press shift button to change value Press HOLD button will save measuring time,and exit the assign status. When the measureing time is greater than zero and the test lock is unlocked,meter will activate the timer function, the meter will be automatically stop the test when the time is longer than preset time.
  • Page 46 OE 4002 MULTIMETER MEGOHMETRE AND INSULATION TESTER 1000V CAT. III DATA RECORDING IN MULTIMETER MODE Press MEM button to enter recording status, the meter display ‘MEM’ as follows:In recording status,meter record the measuring value (when the record exceed 100 counts, the meter only record the last 100 counts).
  • Page 47 OE 4002 MULTIMETER MEGOHMETRE AND INSULATION TESTER 1000V CAT. III When the remain key time is zero ,the secondary screen display the counts of the recorded value as follows Press MEM button ,the secondary screen display the sequence number of the recorded value and the Primary display corresponding value.
  • Page 48 OE 4002 MULTIMETER MEGOHMETRE AND INSULATION TESTER 1000V CAT. III When the key remain time is zero,the meter will be back to Record status. Data Recording in insulation test mode In insulation test mode, the recording function will be activated, press MEM button to view the recorded value, the detailed operation is the same as data-recording in multimeter mode.
  • Page 49: Making Basic Measurements

    OE 4002 MULTIMETER MEGOHMETRE AND INSULATION TESTER 1000V CAT. III MAKING BASIC MEASUREMENTS MEASURING DC VOLTAGE Switch rotary switch to Switch rotary switch to Position, Input terminals and test leads connecting as follows fi gure, then connect test Position, Input terminals and test leads connecting as follows fi gure, then connect test leads to circuit.
  • Page 50: Measuring Ac Voltage

    OE 4002 MULTIMETER MEGOHMETRE AND INSULATION TESTER 1000V CAT. III MEASURING AC VOLTAGE...
  • Page 51 OE 4002 MULTIMETER MEGOHMETRE AND INSULATION TESTER 1000V CAT. III True RMS Meters accurately measure distorted waveforms, but when the input leads are shorted together in the AC functions, the Meter displays a residual reading between 1 and 30 counts. When the test leads are open, the display readings may fl...
  • Page 52: Measuring Temperature

    OE 4002 MULTIMETER MEGOHMETRE AND INSULATION TESTER 1000V CAT. III MEASURING TEMPERATURE The Meter measures the temperature of a type-K thermocouple (included). Choose between degrees Celsius (°C) or degrees Fahrenheit (°F) by pressing Shift Button. When the type-K thermocouple not connect to meter, the meter display the ambient temperature the Meter is rated for -30°C to 1300°C, the included K-type thermocouple is...
  • Page 53 OE 4002 MULTIMETER MEGOHMETRE AND INSULATION TESTER 1000V CAT. III MEASURING RESISTANCE AND MEASURING CAPACITANCE To avoid possible damage to the Meter or to the equipment under test, disconnect circuit power and discharge all high voltage capacitors before testing for continuity.
  • Page 54 OE 4002 MULTIMETER MEGOHMETRE AND INSULATION TESTER 1000V CAT. III MEASURING CONTINUITY AND MEASURING DIODE The continuity test and diode test features a beeper that sounds as long as a circuit is complete. The beeper sounds when a short (<30 )or forward voltage lower than 300mV.
  • Page 55: Measuring Ac Or Dc Current

    OE 4002 MULTIMETER MEGOHMETRE AND INSULATION TESTER 1000V CAT. III MEASURING AC OR DC CURRENT Check fuse is good before Test; Select proper input terminal,rotary switch,range ; not to measuring the current exceed the meter current rating (400mA) Turn power OFF to the circuit under test, break circuit, insert Meter in series,then turn power on...
  • Page 56: Measuring Frequency

    OE 4002 MULTIMETER MEGOHMETRE AND INSULATION TESTER 1000V CAT. III MEASURING FREQUENCY In Measuring AC Voltage mode, Press Hz button Longer than 1S, the meter switch measuring voltage to frequency In Frequency mode, the Range button is invalid. press Hz button, the meter will switch to measuringAC Voltage.
  • Page 57: Insulation Test

    OE 4002 MULTIMETER MEGOHMETRE AND INSULATION TESTER 1000V CAT. III INSULATION TEST Insulation tests should only be performed on dead circuits. Check the fuse and test leads before testing. Switch rotary to Insulation position. if meter displays Switch rotary to Insulation position. if meter displays , please replease battery.
  • Page 58 OE 4002 MULTIMETER MEGOHMETRE AND INSULATION TESTER 1000V CAT. III...
  • Page 59: General Specifications

    OE 4002 MULTIMETER MEGOHMETRE AND INSULATION TESTER 1000V CAT. III GENERAL SPECIFICATIONS Complies with IEC/ EN 61010-1 1000V CAT III, 600 V CAT IV. 1000V DC Voltage, 750VAC Voltage (TRMS). 6600 Count (except for capacitance, temperature,insulation). When the input terminals is V and COM, The overload protective voltage is up to AC 250 V (TRMS) ; When the input terminals is mA and COM, protective Current is 0.4A;...
  • Page 60 OE 4002 MULTIMETER MEGOHMETRE AND INSULATION TESTER 1000V CAT. III ACCURACY DC VOLTAGE Range Resolution Accuracy 660mV 0.1mV 0.1mV 6.6V ±(0.5%+5) 10mV ±(0.5%+5) 660V 100mV ±(0.5%+5) 1000V ±(0.5%+5) CAPACITANCE Range Resolution Accuracy 660mV 0.1mV - - - - - - 6.6V...
  • Page 61 OE 4002 MULTIMETER MEGOHMETRE AND INSULATION TESTER 1000V CAT. III RESISTANCE Range Resolution Accuracy ±(1.2%+5) 6.6K ±(1.2%+5) ±(1.2%+5) 660K ±(1.2%+5) 6.6M ±(2.0%+20) ±(2.0%+20) CAPACITANCE Range Resolution Accuracy 66nF 10pF ±(5.0%+20) 660nF 0.1nF ±(5.0%+20) 6.6 F ±(5.0%+20) 66 F 10nF ±(5.0%+20) 660 F 0.1 F...
  • Page 62 OE 4002 MULTIMETER MEGOHMETRE AND INSULATION TESTER 1000V CAT. III FREQUENCY Range Resolution Accuracy 660.0Hz 0.1Hz ±(1.5%+5) 6.600Hz ±(1.5%+5) 66.00Hz 10mV ±(1.5%+5) >10kHz - - - - - - - INSULATION Output Voltage Display Range Resolution Accuracy 0~5M 0.01M ±(3%+5)
  • Page 63 OE 4002 MULTIMETER MEGOHMETRE AND INSULATION TESTER 1000V CAT. III ACCESSORIES Item Quantity Test Leads Clips K Type Thermocouple Battery AA LR6 Manual Multi-Function Socket...
  • Page 64 FRANCE Tél. +33 (0)4 79 72 62 22 Fax. +33 (0)4 79 72 52 86 OE 4002 MULTIMETRE MEGOHMMETRE ET TESTEUR D’ISOLEMENT 1000V CAT. III MULTIMETER MEGOHMETRE AND INSULATION TESTER 1000V CAT. III Si vous avez besoin de composants ou de pièces, contactez le revendeur En cas de problème veuillez contacter le technicien de votre distributeur agréé...