5. operation
5.1.
Before starting, consideration should be given to the positioning of the vehicle in relation to the external
venting required for the ducting.
5.2.
the unit is normally stored in the vertical position with the 3 metre length of flexible ducting inside the
aluminium tube.
5.3.
Wheel the unit close to the vehicle.
5.4.
to prepare the unit for use loosen the tube clamp butterfly nut and the two height adjusting knobs and
swing the unit into the horizontal position. Keep hold of the filter on the back end of the tube to stop it
falling out. slide the aluminium tube within its clamping bracket until it is in balance and then tighten the
plastic butterfly nut.
5.5.
to adjust the height of the tube in relation to the exhaust, hold the aluminium tube either side of the clamps
and slide it out of the slot it is in and up or down to the required height. move the clamps into the nearest
convenient slots and tighten them.
5.6.
extend the flexible ducting and place the filter in a position where the exhaust fumes can be vented outdoors.
5.7.
the unit should be positioned so that the exhaust pipe is within the cone but not touching it.
5.8.
connect the workshop air supply to the ball valve at the base of the cone using the hook up recommended in section 4. Alternatively an
adequately specified portable air compressor can be used. see specification in section 3.
5.9.
turn the air supply on and open the ball valve on the unit.
5.10.
start the vehicles engine and check that the exhaust fumes are being properly extracted. if adjustments are required to the positioning of
the unit, turn the engine off first.
note: for cars with twin exhausts, an accessory is available. order model no: efs07de (fig.2).
6. maintenance
6.1.
Keep the extractor clean and repair or replace any damaged parts.
6.2.
clean the ducting outlet filter once a week. refer to fig.3. squeeze and remove the spring clip (6). remove the outer filter plate (5) and
the two layers of filter material (3 & 4). Wash the filter material in ordinary detergent and let it dry. Place the inner grille (2) back into the
filter housing (1) followed by the two filters (3 & 4). Place the outer filter plate (5) over the filters and retain all parts by squeezing and
re inserting the spring clip (6).
environment protection
recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
note: it is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
important: no liability is accepted for incorrect use of this product.
warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
sealey group, Kempson way, suffolk Business park, Bury st edmunds, suffolk. ip32 7ar
01284 757500
© Jack sealey limited
01284 703534
sales@sealey.co.uk
Original Language Version
fig.2
fig.3
www.sealey.co.uk
efs07| issue: 3 (H,f) 20/02/18

Advertisement

loading