Download Print this page
Motorola MBP66N Quick Start Manual
Motorola MBP66N Quick Start Manual

Motorola MBP66N Quick Start Manual

3-in-1 non-contact baby thermometer
Hide thumbs Also See for MBP66N:

Advertisement

Quick Links

Quick Start Guide
For a full explanation of all features and instructions, please refer to the User's Guide
(available for download from www.motorolastore.com).
1.
CARE
3-in-1 non-contact
1.
baby thermometer
Model: MBP66N
2. Skin surface lipids on the forehead may cause an inaccurate
3. If the temperature of the storage area differs greatly from that of the measuring
4. Gently slide the battery cover back and install 2 x 1.5V
2. How to measure forehead temperature
Make sure the probe is clean before measuring.
1.
2. Press once the
3. Position the thermometer about 3cm (around 1 inch) from
4. Press once the
5. If the temperature measurement is below 38
6. About 30 seconds after use, the thermometer will automatically beep
Note:
• High Temperature Alarm appears in both Forehead
• If the skin is covered with hair, sweat, or dirt, clean the area and wait 10 minutes before
• Ensure that the thermometer is held firmly during measurement and that the patient does
3. General Information
If your product is not working properly, read this Quick Start Guide or the User's Guide.
Contact Customer Service:
Live Chat: motorolastore.support/en
E-mail: support@motorolastore.com
Consumer Products and Accessories Limited Warranty ("Warranty")
Thank you for purchasing this Motorola branded product manufactured under license by
Binatone Electronics International Ltd. ("BINATONE").
What Does This Warranty Cover?
Subject to the exclusions contained below, BINATONE warrants that this Motorola
branded product ("Product") or certified accessory ("Accessory") sold for use with this
product is manufactured to be free from defects in materials and workmanship under
normal consumer usage for the period outlined below. This Warranty is your exclusive
warranty and is not transferable.
Who Is covered?
This Warranty extends only to the first consumer purchaser, and is not transferable.
What Will BINATONE Do?
BINATONE or its authorized distributor, at its option and within a commercially
reasonable time, will at no charge repair or replace any Products or Accessories that
does not conform to this Warranty.
We may use functionally equivalent reconditioned/refurbished/pre-owned or new
Products, Accessories or parts.
What Other Limitations Are There?
ANY IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE,
SHALL BE LIMITED TO THE DURATION OF THIS LIMITED WARRANTY, OTHERWISE THE
REPAIR OR REPLACEMENTPROVIDED UNDER THIS EXPRESS LIMITED WARRANTY
IS THE EXCLUSIVE REMEDY OF THE CONSUMER, AND IS PROVIDED IN LIEU OF ALL
OTHER WARRANTIES, EXPRESS OR IMPLIED.
IN NO EVENT SHALL MOTOROLA OR BINATONE BE LIABLE, WHETHER IN CONTRACT
OR TORT (INCLUDING NEGLIGENCE) FOR DAMAGES IN EXCESS OF THE PURCHASE
PRICE OF THE PRODUCT OR ACCESSORY, OR FOR ANY INDIRECT, INCIDENTAL,
SPECIAL OR CONSEQUENTIAL DAMAGES OF ANY KIND, OR LOSS OF REVENUE OR
PROFITS, LOSS OF BUSINESS, LOSS OF INFORMATION OR OTHER FINANCIAL LOSS
ARISING OUT OF OR IN CONNECTION WITH THE ABILITY OR INABILITY TO USE
THE PRODUCTS OR ACCESSORIES TO THE FULL EXTENT THESE DAMAGES MAY BE
DISCLAIMED BY LAW.
Some jurisdictions do not allow the limitation or exclusion of incidental or consequential
damages, or limitation on the length of an implied warranty, so the above limitations or
exclusions may not apply to you. This Warranty gives you specific legal rights, and you
may also have other rights that vary from one jurisdiction to another.
Products Covered
Consumer Products
Consumer Accessories
Consumer Products and
Accessories that are
Repaired or Replaced
Setting up the 3-in-1 non-contact baby Thermometer
The key to obtaining accurate readings is a clean sensor. To
clean the sensor, use a cotton swab slightly moistened with
alcohol to gently wipe its surface, and then immediately
wipe dry using a clean cotton swab. Wait at least 20
minutes to make sure that the sensor is completely dry
before taking temperature.
measurement, so make sure the forehead is clean. If you
clean the forehead, please keep waiting a further 5 to 10
minutes before measuring.
area, please wait until the thermometer temperature has equalized to the room
temperature, about 30 minutes, prior to use.
AAA size alkaline batteries (which can be found inside
the packaging) according to the proper polarity, slide
the battery cover back, press the
thermometer on.
Press the
button to power on the thermometer. When
the device is ready, ' - - ' will appear on the screen.
button to select the Forehead
the center of the forehead with the sensor aimed between
the eyebrows.
button, when the measurement is
completed, it will end with a confirmation tone.
will be appeared on display and the Green LED will be on. If the
reading is 38
C/100.4
0
display and the Red LED will be on.
and shut off.
Mode. When taking a patient's temperature, ensure that the thermometer is in Forehead
Mode; the
symbol appear on the display.
taking a measurement.
not move until the measurement is completed, movement may impact the measurement.
button to turn the
F or above,
symbol will be appeared on
0
Length of Coverage
One (1) year from the date of the products, original
purchase by the first consumer purchaser of the product.
Ninety (90) days from the date of the Accessories, original
purchase by the first consumer purchaser of the product.
The balance of the original warranty or for Ninety (90)
days from the date returned to the consumer, whichever is
longer.
Mode.
1inch/3cm
C/100.4
F, a
symbol
0
0
Mode and Forehead/Silent
US_EN
1inch/3cm
F

Advertisement

loading

Summary of Contents for Motorola MBP66N

  • Page 1 Model: MBP66N wipe dry using a clean cotton swab. Wait at least 20 minutes to make sure that the sensor is completely dry before taking temperature.
  • Page 2 • Refer to further guidance below regarding the EMC environment in which the device should be used. Model name: NT17 Ref. no. MBP66N Standard Specification for Infrared Thermometer: ASTM E 1965-98 : 2016 China Manufacturing License(s) : SSYJXSCX20040018 Registration Certificate(s) : SXZZ20182200808 Manufacturer : AViTA (WuJiang) Co.LTD.