GR-297/60L/180
TECHNICAL CHARACTERISTICS
OPERATION VOLTAGE
MAXIMUM POWER CONSUMPTION
BATTERY (Ni-MH)
BATTERY PROTECTION
INDICATIONS - CONTROLS
CHARGE TIME
MINIMUM DURATION
LIGHT SOURCE
EMERGENCY ILLUMINATION
DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH
OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY
CONSTRUCTION MATERIAL
EXTERNAL DIAMENTION
WEIGHT
GUARANTEE
GENERAL
These luminaires are used indoors ta
where emergency light is needed.
E a c h l u m i n a i r e m u s t b e p e r m a n e n t l y
connected to mains power supply.
In normal operation the battery is charging and
the illumination source, lights.
In case of a mains power supply failure the
luminaire will light the illumination source
automatically in emergency mode. When the
mains power supply is restored the device
turns to normal operation.
INSTALLATION
To install the luminaire follow the installation
instructions on page 2.
ΑΤΤΕΝΤΙΟΝ!
!!
1. Operations for installation, maintainance or
testing must be done by authorized personel
only.
2. The device must be connected to the mains
power supply thru a fuse dependent by the
total amount of the line's power load.
3. It is sugested to check every month the
indication LED for battery charging, and by
pushing the TEST button (use a pointy tool
with
diameter of 2mm max.) to check the
emergency cirquit. The illumination LEDs
should light as long as the TEST button is
pressed
. In the opposite condition contact the
installer.
4. It is sugested to check every 6 months the
m i n i m u m a u t o n o n o u s d u r a t i o n b y
Page 1 from 4
SPOT LIGHT
EN 60598-1, EN 60598-2-22, ΕΝ 55015, ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3
Thank you for your trust in our products.
Olympia Electronics - European manufacturer.
o
(
40 C)
MAINTAINED
LUMINAIRE WITH WHITE LEDs
FOR LED MODULE SPECS (see page 4)
220-240V AC/50-60Hz
5.9W / 7.3VA
4.8
V/
Discharge and over charge protection
Battery charging LED TEST button
24 hours
3 h
our
White LEDs
350lm / 110
IP40
5 t o 40 C
Up to 95%
Bayblend FR3010, clear polycarbonate
Ø125 x 65 mm
470gr.
3 years (1 year for the battery)
disconnecting the mains power supply Count
the time that the luminaire lights and in case of
less time than the minimum autonomous
duration the battery must be replaced. If the
measured time is considerably less than the
minimum autonomous duration
installer.
In case of battery or light source
replacement, these must be replaced by parts
of the same type, by the manufacturer or by a
competent person.
5. In case of inactive use for a period greater
than 2 months, disconnect the battery by pulling
out the battery's connector.
6. I s not allowed to discard batteries in to
t i
common trash bins, they must be
discarded only
points. Do not incinerate.
NOTE: LED= Light Emitting Diode
LABELING EXPLANATION:
X: Self contained
1: Maintained (*)
A: Including test device
180: 3 hour duration
(*) Maintained operation: The luminaire lights its
illumination source, when it is powered by the
mains power supply or not.
Non-Maintained operation: The luminaire lights
its illumination source, only in power supply's
failure.
EMERGENCY
1.2
Ah
,
s
lm
o
contact the
in battery recycling
923297000
.