Overview: Important! Please read these instructions carefully before installing and operating the high-pressure cleaner. Circuit diagram and codes: Fig. 1 a = Water outlet n = black b = Water inlet with filter b = white c = Rotating nozzle (special accessory) a = blue d = Adjustable nozzle head r = red...
Observe the regulations of your local water 2. Safety regulations board. Under DIN 1988, the high-pressure cleaner can be connected up to the drinking- water supply only if the feed pipe is fitted with a Warning: safety device to prevent backwater with drainage.
Motor: Safety system The safety valve also functions as a pressure limiting Voltage 230V ~ 50Hz device. When the pistol is closed, the valve opens Extension up to 25 m cross section 3 x 1.5 mm and allows the delivered water to circulate in the pump.
Connect the water supply hose (not supplied) to 5. Operation the inlet of the high-pressure cleaner. The hose must measure at least 13 mm in diameter. The Open the water tap as far as it will go. water supply must have sufficient pressure to Press the pistol trigger (Fig.
Using detergent Correct use of the rotating nozzle (only for models with a rotating nozzle) Fill the tank of the foam spray lance with detergent (capacity approx. 0.5 l). To enhance washing performance, use the rotating Set the nozzle to „flat jet“ and attach the tank for nozzle supplied as follows: foam cleaning.
6. Maintenance Clean the nozzle head using the cleaner supplied. After dismantling the lance (Fig. 6c), remove any dirt from the borehole on the head (Fig. 6d) and rinse thoroughly. Important! Always disconnect from the mains before doing any maintenance or repair work. To maintain the high-pressure cleaner in perfect working order, the intake filter must be checked and cleaned after every 50 hours of operation.
Page 8
7. Faults and their remedies Fault Cause Remedy - Pump does not - Wrong or worn nozzle -Replace nozzle generate the prescribed - Intake filter is clogged - Clean filter pressure - Inadequate water supply - Open tap as far as it will go - Air is being drawn in - Check connections - Pump has not been rinsed out...
WARRANTY CERTIFICATE The guarantee period begins on the sales date and is valid for 1 year. Responsibility is assumed for faulty construction or material or functional defects. Any necessary replacement parts and necessary repair work are free of charge. We do not assume responsibility for consequential damage.