TrueAlert ES Addressable Indoor Audible Notification Appliance installation instructions

Cautions, warnings, and regulatory information

Important: When the notification appliance emits light or sound, it indicates the possibility of an emergency situation that requires immediate atten-
tion of all occupants.
SAFETY: Always install, maintain, and test notification appliances within their specifications. Failure to follow all safety precautions and
instructions may result in loss of life and property due to non-functioning notification appliances. Some notification appliances use high
voltage. To avoid electrical hazards and avoid damage to appliances, make sure that the electrical power for the Notification Appliance
Circuit is disconnected at the control panel before installing, repairing, or internally adjusting any notification appliances. Even with
electrical power removed, some notification appliances (such as visible strobes) store a high voltage charge. The high voltage can cause
injury resulting in death from electrical shock. DO NOT TOUCH EXPOSED CIRCUITRY.
LOCATION REFERENCE: Location and quantity of appliances required must conform to the applicable local standards and guidelines
(the National Fire Alarm and Signaling Code (NFPA 72); ULC Standard CAN/ULC-S524, Installation of Fire Alarm Systems; the appropriate
model building codes, etc.) and specific requirements of the local Authority Having Jurisdiction (AHJ). These notification appliances are
not intended for installation within hazardous locations as defined by the National Electrical Code (NEC) or NFPA.

UL listed TrueAlert ES indoor product identification reference

Type
Wall Mount
Audible Only
(A/O)

Operation

These appliances provide an audible (AO) warning of an alarm condition when activated from the control panel of a compatible
UL/ULC Listed, Autocall Fire Alarm System.
Note: For information about TrueAlert ES appliance testing, see TrueAlert ES Addressable LED Appliances Troubleshooting (579-1168AC).

Required parts:

*Appliance x1.
*Autocall parts
*Cover x1.
6-32 1 inch mounting screws (x2). Do not over tighten.
Single gang electrical box, 1-1/2 inch minimum depth required.

Mounting instructions

1.
Select the mounting location, and install the electrical box.
2.
Connect the building wires to the appliance. See
3.
Use the provided hardware to secure the appliance to the electrical box.
4.
Set the appliance settings. See
5.
Attach the cover to the appliance.
Table 1: Product identification reference
Colors
Models
Red
Components:
White
A59AO-APPLWR
A59AO-APPLWW
Wiring
instructions.
Setting the address DIP
switch.
Figure 1: Mounting instructions
Covers:
A59AOC-WWFAB
A59AOC-WRF
A59AOC-WWF
A59AOC-WRFAB
*05791200ACD*
A59AOC-WRS
A59AOC-WWS
579-1200AC Rev. D

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the A59AO-APPLWR and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Autocall A59AO-APPLWR

  • Page 1 These appliances provide an audible (AO) warning of an alarm condition when activated from the control panel of a compatible UL/ULC Listed, Autocall Fire Alarm System. Note: For information about TrueAlert ES appliance testing, see TrueAlert ES Addressable LED Appliances Troubleshooting (579-1168AC).
  • Page 2 TrueAlert ES Addressable Indoor Audible Notification Appliance installation instructions Wiring instructions WARNING: Make sure that all power is disconnected before starting the installation. At the electrical box, connect the building wiring to the CKT + and CKT - terminals on the assembly. To ensure proper continuity, use a torque wrench to tighten the terminal block screws to 12-15 inch-pounds.
  • Page 3 TrueAlert ES Addressable Indoor Audible Notification Appliance installation instructions Setting the address DIP switch Each addressable TrueAlert ES notification appliance has a unique address that is set with an eight-position DIP switch (ADDR1). Assign up to 127 unique addresses to an SLC, however, the total appliance loading available may be less due to appliance current requirements. To set the address, complete the following steps: Locate the 8-position DIP switch on the bottom left front of the appliance, see Figure 3.
  • Page 4 * For connection to IDNAC SLCs © 2019 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision and are subject to change without notice. Additional listings may be applicable, contact your local Autocall product supplier for the latest status.

This manual is also suitable for:

A59ao-applww

Table of Contents