ABB generator interfaces

Quick installation guide

4000/7200-WIND-INTERFACE-EU
PVI-7200-WIND-INTERFACE
EN
In addition to what is explained below, the safety and installation information provided in the
installation manual must be read and followed. The technical documentation and the interface
and management software for the product are available at the website.
The device must be used in the manner described in the manual. If this is not the case the
safety devices guaranteed by the inverter might be ineffective.
3.
Available components
M6 screw
ABB
XXXXX
solar
inverters
XXXXX
XXXXX
XXXXX
XXXXX
XXXXX
XXXX
XXXX
Technical documentations
In addition
The
technical
to what
documentatio
is explained
n and
in this
guide,
the
interface
the
safety
and
management
and
software
installation
information
for the
product
provided
are
in the
available
installation
at the
website.
manual
t be
mus
read
and
followed.
4.

Transport and handling

Transport of the equipment, especially by road, must be carried out with by suitable ways and means for protecting the components from violent shocks,
humidity, vibration, etc.

Lifting

The means used for lifting must be suitable to bear the weight of the equipment.

Unpacking and checking

The components of the packaging must be disposed on in accordance with the regulations in force in the country of installation.
When you open the package, check that the equipment is undamaged and make sure all the components are present. If you find any defects or damage, stop
unpacking and consult the carrier, and also promptly inform the Service ABB.
Equipment weight
Model
Mass weight
4000-WIND-INTERFACE-EU
7200-WIND-INTERFACE-EU
< 1.8 Kg/4.0lb
PVI-7200-WIND-INTERFACE
5.
Environmental checks
- Consult the technical data to check the environmental parameters to be observed
- Installation of the unit in a location exposed to direct sunlight must be avoided as it may cause:
1. premature wear of the electrical/electromechanical components
2. premature wear of the mechanical components (gaskets)
- Do not install in small closed rooms where air cannot circulate freely
- To avoid overheating, always make sure the flow of air around the inverter is not blocked
- Do not install in places where gases or flammable substances may be present
- Do not install in rooms where people live or where the prolonged presence of people or animals is expected, becau-
se of the noise (about 50dB(A) at 1 m) that the Wind-Interface makes during operation
Installations above 2000 metres
On account of the rarefaction of the air (at high altitudes), particular conditions may occur:
- Less efficient cooling and therefore a greater likelihood of the device going into derating because of high internal
temperatures
- Reduction in the dielectric resistance of the air that, in the presence of high operating voltages (DC input), can
create electric arcs (discharges) that can reach the point of damaging the Wind-Interface
All installations at altitudes of over 2000 metres must be assessed case by case with the ABB Service department.
NO
NO
Installation position
- Install on a wall or strong structure capable of bearing the weight of the equipment
- Install in safe, easy to reach places
OK
NO
- If possible, install at eye-level so that the display and status LEDs can be seen easily
- Install at a height that considers the heaviness of the equipment
- Install vertically with a maximum inclination of +/- 5°
- Choose a place with enough space around the unit to permit easy installation and removal of
the object from the mounting surfaces; comply with the indicated minimum distances
- For a multiple installation, position the inverters side by side; if the space available does not
20
allow this arrangement, position the inverters in a staggered arrangement as shown in the
cm
figure so that heat dissipation is not affected by other inverters
Final installation of the Wind-Interface must not compromise access to any disconnec-
20 cm
20 cm
tion devices that may be located externally.
Please refer to the warranty terms and conditions available on the website and evaluate
any possible exclusion due to improper installation.
20
cm
Quantity
4
1
1.
The labels on the Wind box have the Agency marking, main technical data and identification of the equipment and manufacturer
The labels attached to the equipment must NOT be removed, damaged, dirtied, hidden,etc...
If the service password is requested, the field to be used is the serial number -SN: YYWWSSSSSS-
In the manual and/or in some cases on the equipment, the danger or hazard zones are indicated with signs, labels, symbols or icons.
Always refer to instruction
manual
Protection rating of
IP65
equipment
Positive pole and negative
pole of the input voltage
(DC)
2.
The model of the generator interface to which this guide refers is 4000/7200-WIND-INTERFACE-EU and PVI-7200-WIND-INTERFACE.
01
WIND INPUT
WIND
SPEED
+ -
1
Main components
Tachometer output
DC output terminal
01
05
teminal block
block
Three phase input
Front cover
02
06
terminal block
Diversion (dump) load
03
07
Heat sink
terminal block
Ground connection
Three phase cable
04
08
screw
inlet
6.
Wall/Pole mounting
During installation, do not place the Wind-interface with its front facing
towards the ground.
- Position the Wind-Interface so that it is perfectly level on the wall and use it as
a boring template.
- Make the 4 holes required, using a drill with a 10 mm diameter bit. The depth of the
holes should be about 30 mm.
- Secure the Wind-Interface to the wall using the four provided bolts and screws.
Check the stability of the Wind-Interface
- Unscrew the four screws and open the frontal cover in order to make all
necessary connections
- Once the connections have been made, close the cover by tightening the 4
screws on the front to a minimum tightening torque of 1.5 Nm.
7.
The following is a block diagram of a wind power system comprising the 7200-WIND-INTERFACE-EU rectifier.
Wind Turbine
Diversion (dump) resistor (opt.)
AC Switch S1
OK
8.
OK
The 4000/7200-WIND-INTERFACE is a passive rectifier designed to transform AC current from a wind turbine permanent magnet generator into a continuous
(DC) current to be input to one or more ABB inverters, and for connection to diversion (dump) resistors. The WIND-INTERFACE does not supply a safety
system for the wind turbine.
Limits on use
The inputs of the rectifier may be connected only to a wind-turbine, not to batteries or other sources of power.
NO
The WIND-INTERFACE must be used only within its technical specifications and ratings.
01
02
General warning - Important
Hazardous voltage
safety information
Without isolation
Temperature range
transformer
Always use safety clothing
Point of connection for
and/or personal safety
grounding protection
devices
06
03
02
05
BULK OUT
+
-
BRAKE
-
+
2
3
04
Tachometer output cable inlet
09
Diversion (dump) load cable
10
inlet
11
DC output cable inlet
Diversion load activation LED
12
01
XXXX-WIND-INTERFACE-EU
01
03
02
04
P/N:PPPPPPPPPPP
SN:YYWWSSSSSS WK:WWYY
SO:SXXXXXXXX Q1
05
Wind interface model
01
Principal technical data
02
Part Number
03
Week/Year of manufacture
04
Serial Number
05
Hot surfaces
Direct and alternating
currents, respectively
Time need to discharge
stored energy
10
08 09
10
11
12
07
08 09
10
11
12
07
AC Switch S2

Advertisement

loading

Summary of Contents for ABB 4000-WIND-INTERFACE-EU

  • Page 1 - Install vertically with a maximum inclination of +/- 5° (DC) current to be input to one or more ABB inverters, and for connection to diversion (dump) resistors. The WIND-INTERFACE does not supply a safety - Choose a place with enough space around the unit to permit easy installation and removal of system for the wind turbine.
  • Page 2 EN 50178, EN 61000-6-2 EN 50178, EN 61000-6-2 IEEE1547, CSA C22.2 107.1- 01-2001 WIND INPUT BRAKE WIND SPEED Contact us WIND INTERFACE BOX4000-7200-Quick Installation Guide EN-RevA EFFECTIVE 2014-04-02 © Copyright 2014 ABB. All Rights Reserved. www.abb.com/converters-inverters Specifications subject to change without notice.

This manual is also suitable for:

7200-wind-interface-euPvi-7200-wind-interface