6" (152mm) Temperature Chart Recorder
Quick Start
1. Remove the protective pen cap.
2. Connect Probe: Make sure the KTC probe is connected firmly to the Replaceable Sensor and that the Replaceable
Sensor is plugged in firmly to the chart recorder.
3. Insert 4 AA batteries and plug in AC adapter. Unit will power on.
4. The instrument will move pen to the appropriate readings.
5. Install the chart that matches the Dip Switch settings you have selected.
a. Press the PEN HOME key to move the pen to the outside of the chart. The pen is automatically raised off the chart.
b. Remove the old chart, place the new chart on the Chart Hub being certain that the edge of the chart slides under
the Chart Guide Clip located at the outside of the chart.
6.
Set the appropriate time. There are two ways to adjust the chart and set the appropriate time:
a. Set the chart time manually by inserting a coin into the groove in the chart hub and turning clockwise until the
correct hour (and day if applicable) on the chart is referenced to the timing arrow (just to the right of the pen tip on the
dial). Press Pen Home to move the pen(s) back onto the chart.
The following feature should be used for fine adjustments only:
b. To adjust the chart time, press and hold Adjust-Up and Adjust-Down buttons located on the back of the unit next to
the dip switch.
The green LED will blink rapidly for about five seconds, then the LED will remain solid green. While in this state the
Adjust-Up button will move the chart backward (counter clockwise) and the Adjust-Down button will move the
chart forward (clockwise).
Rotate the chart until the correct hour (and day if applicable) on the chart is referenced to the timing arrow. Once
you have set your chart, press the Pen Home button to exit Chart Adjust Mode. The unit will take one minute to exit the
Chart Adjust Mode once Pen Home is pressed. Press Pen Home to move the pen(s) back onto the chart.
7.
Place the KT6 recorder on a flat vibration-free surface. Be sure it is in a vertical position and level. For best
performance and longevity, the location should be a clean environment, free from dust and corrosive fumes. Do not
exceed temperature specifications. Wall Mount: Keyhole slots are provided on the KT6 recorder for wall mounting.
KT6P1, KT6P2, KT6P5

Advertisement

loading

Summary of Contents for Alpha Dickson KT6P1

  • Page 1 KT6P1, KT6P2, KT6P5 Phone: 1-800-757-3747 or 1-630-543-3747 | Fax: 1-630-543-0498 | Email: support@dicksondata.com | Website:DicksonDate.com 6” (152mm) Temperature Chart Recorder Quick Start 1. Remove the protective pen cap. 2. Connect Probe: Make sure the KTC probe is connected firmly to the Replaceable Sensor and that the Replaceable Sensor is plugged in firmly to the chart recorder.
  • Page 2 Display Symbols and Button Operations On/Off The On/Off key turns the unit on and off. Pen Home If the pen is located on the outside edge of the chart, press the PEN HOME to move pen to recording position. If the pen is located on the chart, press the PEN HOME key to move the pen to the outside edge of the chart Alarm - (KT6P3 and KT6P5) 1.
  • Page 3: Alarm Relays

    Alarm Relays The SPST 24V 500mA relay contacts are normally open and will close on alarm conditions when the alarms are enabled. Relay contacts are always functional when the alarm is enabled. The relay will close only during minimum and maximum alarm conditions.
  • Page 4: Led Indicators

    Pen Adjust Pen adjust may be needed if the pen(s) and display do not match. While the unit is on, press and hold both the Pen Home button and the On/Off button (making sure to press the Pen Home button first so the unit will not turn off). The led will blink rapidly between amber and green for about five seconds.
  • Page 5: Warranty

    Warranty Dickson warrants that the products it sells will be free from defects in material and workmanship under normal use and service for a period of twelve months after delivery. In the event of a claim under this warranty, the product or part must be returned to the factory for repair or replacement (shipping pre-paid) with a Return Authorization Number.