Care and Maintenance
Umwelt-Geräte-Technik GmbH
Eberswalder Str. 58 | D-15374 Müncheberg
phone: +49 (0) 33 43 2 - 89 575 | fax: +49 (0) 33 43 2 - 89 573
e-mail: info@ugt-online.de | www.ugt-online.de

Advertisement

loading
Need help?

Need help?

Do you have a question about the Tensio 100 and is the answer not in the manual?

Questions and answers

Summary of Contents for UGT Tensio 100

  • Page 1 Operating Manual Tensio 100 Version: 22/01/19 Care and Maintenance Umwelt-Geräte-Technik GmbH Eberswalder Str. 58 | D-15374 Müncheberg phone: +49 (0) 33 43 2 - 89 575 | fax: +49 (0) 33 43 2 - 89 573 e-mail: info@ugt-online.de | www.ugt-online.de...
  • Page 2: Table Of Contents

    2.2 Filling and Degassing of the Tensiometer ......................7 2.3 Replacing the ceramic and the O-rings ......................10 Umwelt-Geräte-Technik GmbH | Eberswalder Str. 58 | D-15374 Müncheberg | Tel.: +49 (0) 33 43 2 - 89 575 | www.ugt-online.de Page 2 of...
  • Page 3: Introduction

    In adaption to different applications the Tensio 100 is available in three different types: An additional service to this manual is our tutorial on how to refill the Tensio 100 which can be found at the following link: https://www.ugt-online.de/en/products/soil-science/tensiometers/tensio-100/...
  • Page 4 There are several ways to contact UGT if you need a quote or product information please contact Email: info@ugt-online.de For any technical assistance or feedback or in case of problems with your product please contact Email: support@ugt-online.de We look forward to your inquiries or questions and are with pleasure at your disposal.Phone: + 49 (0) 33432 –...
  • Page 5: Safety Instructions

    Do not twist pressure measurements, especially when using the manometer version of the transducer Tensio 100. Umwelt-Geräte-Technik GmbH | Eberswalder Str. 58 | D-15374 Müncheberg | Tel.: +49 (0) 33 43 2 - 89 575 | www.ugt-online.de Page 5 of...
  • Page 6: Care And Maintenance

    Care and Maintenance The Tensio 100 tensiometers are largely maintenance-free and factory calibrated. They do not require regu- lar maintenance or calibration routines. However, suitable maintenance and storage can increase signifi- cantly the functionality and the life-time of the instrument.
  • Page 7: Filling And Degassing Of The Tensiometer

    Most frequent causes for leaks are wet ceramic cups, loose ceramic cups or damaged ce- ramic cups. If the ceramic cup is damaged it needs to be exchanged. Umwelt-Geräte-Technik GmbH | Eberswalder Str. 58 | D-15374 Müncheberg | Tel.: +49 (0) 33 43 2 - 89 575 | www.ugt-online.de Page 7 of...
  • Page 8 Notch visible Umwelt-Geräte-Technik GmbH | Eberswalder Str. 58 | D-15374 Müncheberg | Tel.: +49 (0) 33 43 2 - 89 575 | www.ugt-online.de Page 8 of...
  • Page 9 Repeat steps 1 to 5 if there are still air bubbles visible inside the tensiometer head. An additional service to this manual is our tutorial on how to refill the Tensio 100 which can be found at the following link: https://www.ugt-online.de/en/products/soil-science/tensiometers/tensio-100/...
  • Page 10: Replacing The Ceramic And The O-Rings

    Gloves or a paper towel may prevent direct contact between skin and ceramic. The ceramic must be centered by the spigot. Umwelt-Geräte-Technik GmbH | Eberswalder Str. 58 | D-15374 Müncheberg | Tel.: +49 (0) 33 43 2 - 89 575 | www.ugt-online.de Page 10 of...
  • Page 11 Umwelt-Geräte-Technik GmbH | Eberswalder Str. 58 | D-15374 Müncheberg | Tel.: +49 (0) 33 43 2 - 89 575 | www.ugt-online.de Page 11 of...