4.1.7.
Consult Chart 1 and select the die specified to produce the required flare. Place the die into the cavity as shown with the split line
horizontal and the counter bore towards the operating lever (fig.1).
fig.1
4.1.8.
After the pipe has been prepared as instructed above, ensure the tube nut is fitted to the pipe. Pass the pipe through the rear of the die
until the prepared end is flush with the front face of the die. Ensure that both halves of the die are contacting the die stops (fig.2). Swing
the locking plate into position and tighten the clamping screw. Check that the position of the pipe and die are still correct.
fig.3
4.1.9.
Select required OP.1 punch by rotating the turret so that it is facing and in line with the pipe, fig.3.
4.1.10.
Pull the lever to engage the punch into the end of the brake pipe and continue to form the flare until a solid resistance is felt (fig.4). Return
the handle to the original position to withdraw the punch. If the required flare calls for a second operation in Chart 1, rotate the turret until
the Op.2 punch is facing and in line with the brake pipe. Operate the lever to complete the form of the flare.
Return the lever to the original position to withdraw the punch. Release the clamping screw and swing the clamp open and remove the
dies with the pipe.
If necessary a gentle tap on a suitable surface will release the dies from the pipe.
Check the quality of the flare to ensure the pipe did not move during the flaring.
IMPORTANT
The punches and dies supplied for this tool must only be used with this equipment.
Parts support is available for this product. Please email sales@sealey.co.uk or telephone 01284 757500
ENVIRONMENT PROTEcTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice. Please note that other versions of this product are available. If you require documentation for alternative versions, please email or call
our technical team on technical@sealey.co.uk or 01284 757505.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
© Jack Sealey Limited
fig.2
fig.4
01284 703534
sales@sealey.co.uk
Original Language Version
www.sealey.co.uk
PFT07.V2 | Issue:2 (H,F) 09/09/19

Advertisement

loading