Table of Contents

Advertisement

Available languages

Available languages

Perun AB++ was created to protect trigger contacts in the replica, as well as enhance it with
new features. Reading this manual will help you fully exploit this unit's potential and in case
of encountering any problems, you can look for solutions to them here.
Manufacturer:
Perun
Barwicka 8 St.
60-192 Poznań
Poland
e-mail:
info@perunairsoft.pl

Table of contents

1.
Technical data.................................................................................................................................. 2
2.
Installation ....................................................................................................................................... 2
3.
Features and programming ............................................................................................................. 3
4.
Factory settings ............................................................................................................................... 5
5.
Troubleshooting and diagnostic system .......................................................................................... 5
6.
Contacts check ................................................................................................................................. 7
AB++
Manual
1
(Polska wersja instrukcji od strony 7.)

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for Perun AB++

  • Page 1: Table Of Contents

    AB++ Manual Perun AB++ was created to protect trigger contacts in the replica, as well as enhance it with new features. Reading this manual will help you fully exploit this unit’s potential and in case of encountering any problems, you can look for solutions to them here.
  • Page 2: Technical Data

    1. Technical data Recommended power sources Perun AB++ works with any power source that provides voltage between 7 and 17 volts and can deliver enough current to ensure smooth cycling of the replica. Li-Po and Li-Ion batteries with nominal voltage of 7.4, 11.1 or 14.8 volts are recommended.
  • Page 3: Features And Programming

    3. Features and programming To enter the programming mode, press the button on the device 2 times. First push activates the button, which is signaled by LED starting to glow green. Quick second push shortly after the first leads to the programming mode.
  • Page 4 Function and Description LED color Precocking When shooting on semi, precocking keeps the piston in rear position, ready for a shot. This decreases the time between pulling the trigger and the actual shot, increasing realism, and giving advantage in CQB fights. Precocking level must be set so, that the Yellow piston remains around 1,5 cm from the rearmost position.
  • Page 5: Factory Settings

    5. Troubleshooting and diagnostic system Perun AB++ has a diagnostic system that will help you find the source, should you encounter a problem. After the battery is connected, the unit undergoes a start-up check, to make sure the replica is ready to work.
  • Page 6 Problem and LED color Description Unit temperature is too high Too high temperature of the unit (electronic board) was detected. It will not function again until it cools down, after which it will return to normal operation. Yellow and white blinking alternately Battery with too low voltage is Battery with a voltage below 7V is connected.
  • Page 7: Contacts Check

    6. Contacts check AB++ allows you to easily check, whether the trigger contacts in the gearbox or the button on the unit are functioning properly. When the unit is connected to the battery, but disconnected from the motor, it informs about this with yellow, flashing light. If during that time, a properly working and connected trigger contacts will be closed, or the button on the unit will be pressed, the unit will signal that by changing the LED color for a moment.
  • Page 8 AB++ Instrukcja Perun AB++ został stworzony, aby ochronić styki w Twojej replice oraz wzbogacić ją o nowe funkcje. Dokładne zapoznanie się z niniejszą instrukcją pozwoli Ci w pełni wykorzystać potencjał produktu. Zawiera ona schemat instalacji, a także opis i rozwiązanie podstawowych problemów sygnalizowanych przez układ.
  • Page 9: Parametry Techniczne

    1. Parametry techniczne Dopuszczalne rodzaje zasilania Perun AB++ współpracuje z dowolnym źródłem zasilania o napięciu od 7V do 17V, będącym w stanie dostarczyć odpowiednią ilość prądu do zapewnienia płynnej pracy repliki. Zaleca się stosowanie akumulatorów typu Li-Po oraz Li-Ion o napięciu nominalnym 7,4V, 11,1V lub 14,8V. Warto używać...
  • Page 10: Funkcje I Programowanie

    3. Funkcje i programowanie Aby wejść w tryb programowania należy wcisnąć przycisk na układzie 2 razy. Pierwsze wciśnięcie przycisku aktywuje go, czemu towarzyszy zaświecenie się diody LED na zielono. Drugie wciśnięcie szybko po pierwszym pozwala wejść w tryb programowania. Wejście w tryb programowania zasygnalizowane zostanie sygnałem dźwiękowym.
  • Page 11 Funkcja i Opis kolor LED Precocking Precocking pozwala w trybie ognia pojedynczego zatrzymać tłok w tylnej pozycji, co skraca czas pomiędzy wciśnięciem spustu, a padnięciem strzału. Zwiększa to realizm oraz daje przewagę szczególnie w walkach w pomieszczeniach zamkniętych (CQB). Żółty Właściwy poziom precockingu należy ustawić...
  • Page 12: Ustawienia Fabryczne

    Li-Po and Li-Ion alarm – włączony 5. Tryb diagnostyczny Perun AB++ posiada system diagnostyczny, który pomoże w znalezieniu przyczyny ewentualnego problemu. Po podłączeniu akumulatora układ przechodzi diagnostykę, sprawdzając czy replika jest gotowa do działania. Pomyślne przejście przez początkową diagnostykę sygnalizowane jest krótkim zaświeceniem się...
  • Page 13 Błąd oraz kolor LED Opis Podłączono akumulator o zbyt Podłączono akumulator o napięciu poniżej 7V. Należy podłączyć niskim napięciu akumulator o napięciu od 7 do 17V. Żółty i cyjan migające na zmianę Podłączono akumulator o zbyt Podłączono akumulator o napięciu powyżej 17V. Należy wysokim napięciu natychmiast odłączyć...
  • Page 14: Kontrola Styków

    6. Kontrola styków AB++ pozwala łatwo sprawdzić, czy styki spustu w gearboxie działają prawidłowo. Kiedy układ jest podłączony do baterii, ale silnik jest rozłączony, użytkownik jest o tym informowany miganiem diody w kolorze żółtym. Jeżeli w tym czasie prawidłowo funkcjonujące i podłączone styki spustu zostaną zwarte lub przycisk na obudowie zostanie wciśnięty, wówczas dioda zmieni kolor.

Table of Contents