Download Print this page

Sealey CRM101 Instructions page 2

Cable reel system retractable 10/15 mtr

Advertisement

3. MOUNTING / ASSEMBLY
3.1.
fix the cable reel in an appropriate position, ensuring that the wall and the mounting bolts will adequately support the weight of the
reel and the tension of the cable, as it is pulled from the reel.
3.2.
using the bracket as a template, mark the position, on the wall where the cable reel is to be mounted, for two holes. Drill two 10mm
diameter holes in the wall of sufficient depth to take the rawl bolts supplied.
3.3.
Insert the two rawl bolts into the holes, and mount the bracket onto the studs and loosely secure with the flat washers,
spring washers and the nuts supplied. tighten the nuts evenly until the bracket and reel are secure.
3.4.
Ensure that the cable can be pulled out to, and reeled back from, work sites without rubbing on the sides of the cable entry.
4. OPErATION
4.1.
Extending the cable.
4.1.1. As the cable is pulled out from the reel, the action of the ratchet mechanism can be heard alternating between a clicking sound and a
short silent period. If the tension on the cable is released whilst the ratchet is clicking, the cable will remain extended.
If the tension on the cable is released during the silent period, the cable will retract. to stop the cable retracting, pull it out again
until the ratchet starts clicking, and then release it.
4.2.
retracting the cable.
4.2.1. to release the cable and allow it to automatically rewind, pull the cable out from the locked position until the clicking stops and then
release the tension on the cable. Do not let go of the cable, but guide it back smoothly until the socket is back in the reel.
WArNING! the reel tension is factory set, if any adjustment is required, contact an authorised service agent. DO NOT remove any
of the cover screws.
4.3.
Thermal cut-out.
4.3.1. In the event of the reel being overloaded, the cut-out switch will trip. If this occurs, disconnect the reel from the supply and then
determine and rectify the cause of the overload.
4.3.2. reconnect to the supply and press the cut-out reset button - after allowing two to three minutes for cooling down.
Parts support is available for this product. To obtain a parts listing and/or diagram,
please log on to www.sealey.co.uk, email sales@sealey.co.uk or phone 01284 757500.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPOrTANT: no liability is accepted for incorrect use of this product.
WArrANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFOrMATION: for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
Environmental Protection
recycle unwanted materials instead of disposing of them as
waste. All tools, accessories and packaging should be sorted,
taken to a recycle centre and disposed of in a manner which is
compatible with the environment.
When the product is no longer required, it must be disposed of in
an environmentally protective way. contact your local solid waste
authority for recycling information.
Sole UK Distributor, Sealey Group,
Kempson Way, suffolk Business Park,
Bury st. Edmunds, suffolk,
IP32 7Ar
Original Language Version
www.sealey.co.uk
01284 757500
Web
sales@sealey.co.uk
01284 703534
email
crM101, crM151
Issue no: 1 - 29/01/10

Advertisement

loading

This manual is also suitable for:

Crm151