Precautions

Electrical Safety

ViaLite Power Supply Units are Safety Class 1 products (having metal case directly connected to earth via the power supply cable).
The unit is also fitted with an earthing/grounding stud connected to the power supply earth. When operating the equipment note the
following precautions:
Hazardous voltages exist within the equipment. Modules have no user serviceable parts, do not remove covers.
The equipment does not have an external mains isolating switch. Equipment must be installed within easy reach of a dual pole
mains isolation switch.
User replaceable fuses and module replacement should only be carried out by a qualified technician.

ESD Precautions

Precautions for handling electro-static sensitive devices should be observed when handling all ViaLite modules. Technicians should
ensure that they use effective personal grounding (i.e. ESD wrist strap etc.) when servicing the equipment. Any equipment or tools used
should be grounded to prevent static charge buildup. Good practice should be observed at all times for reference see relevant
standards.
EN 61340-5-1, "Protection of Electronic Devices from Electrostatic Phenomena – General Requirements"

Optical Safety

The ViaLite RF Transmitter modules contain laser diode sources operating at nominal wavelengths of 1270nm to 1610nm.
These devices are rated as EN60825-1 CLASS 1 radiation emitting devices. A class 1 laser is safe under all conditions of normal use.
When operating the equipment note the following precautions:
Never look into the end of an optical fibre directly or by reflection either with the naked eye or through an optical instrument.
Never leave equipment with radiating bare fibres – always cap the connectors.
Do not remove equipment external covers when operating.

Modules fitted

Below is a list of module fitted in your ODE-A enclosure and their special configurations
PSU – LH
LPS-A4
PSU – RH
LPS-A4
Module 1
HRT-G5-8M-10-S1310
Module 2
HRT-L5-8M-33-S1310
Module 3
HRT-L5-8M-33-S1310
Module 4
Not fitted
P
ULSE
Issue 2
ViaLiteHD Mains Power Supply for (ODE-A4) Outdoor Enclosure, 90-264VAC i/p
ViaLiteHD Mains Power Supply for (ODE-A4) Outdoor Enclosure, 90-264VAC i/p
ViaLiteHD Transmitter, GPS & Galileo, 1.0-1.8GHz, 50Ω, MCX RF, SC/APC Optical
ViaLiteHD Transmitter, L Band, 700-2450MHz, 50Ω, MCX RF, SC/APC Optical
ViaLiteHD Transmitter, L Band, 700-2450MHz, 50Ω, MCX RF, SC/APC Optical
1
2
3
P
M
L
OWER AND
EASUREMENT
TD
T
: +44 1793 784389 F
EL
E
:
MAIL
SALES
Note
Replaceable fuse, fitted to switch bar - Fuse, 2A, 250V, anti-surge, 20 x 5mm,
PPM part number 57107
Internal fibre connections:
Module 1 = A
Module 2 = B
Module 3 = a
Module 4 = b
ODE-A4 Glandplate connector information
1 = 50 Ohm N-Type (RF1-4)
2 = Neutrik Quad Fibre connector
3 = Neutrik True 1 power input connector
., 65 S
H
B
HRIVENHAM
UNDRED
USINESS
: +44 1793 784391
AX
@
.
W
:
.
VIALITE
COM
EBSITE
WWW
VIALITE
Page 1 of 2
Model: HAA-XX-XX-XX-XXXXX
P
, S
, SN6 8TY, UK.
ARK
WINDON
.
COM
CR4635

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HAA Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ViaLite HAA Series

  • Page 1 Electrical Safety ViaLite Power Supply Units are Safety Class 1 products (having metal case directly connected to earth via the power supply cable). The unit is also fitted with an earthing/grounding stud connected to the power supply earth. When operating the equipment note the following precautions: ...
  • Page 2 Follow the steps below to fit the power connector ., 65 S , SN6 8TY, UK. ULSE OWER AND EASUREMENT HRIVENHAM UNDRED USINESS WINDON : +44 1793 784389 F : +44 1793 784391 MAIL SALES VIALITE EBSITE VIALITE Issue 2 Page 2 of 2 CR4635...

Table of Contents