8. Trouble shooting

Error
Possible cause
The pump does
The pump is out of
not start.
power.
The limit switch is
activated.
The pump starts
The counter
but then stops
pressure is too high.
immediately.
The pressure switch
stops the pump.
There is no
A block in the
suction.
suction filter.
Air in the suction
pipe.
The suction fails
because of small
output caused by a
long suction hose.
The valves are worn
out.
20
Solution
Check the power
cables and
couplings.
Release the limit
switch.
Remove the
possible block,
check the mounting
of the quick coup-
lings or widen the
nozzles.
Clean the filter.
Check the condition
of the suction pipe
and the joints.
Press the Shift
button and hold it
down until the the
suction begins.
Change the valves.
Error
Possible cause
The output is
The valves are worn
weak.
out.
The counter
pressure is too high.
"FLO" alarm.
Flow alarm, flow
below the alarm
level
The controller does
not receive the
pulse data from the
flow sensors.
"ERR1" alarm.
Short circuit in the
sensors.
Solution
Change the valves.
Remove the
possible block,
check the mounting
of the quick coup-
lings or widen the
nozzles.
Make sure there is
still liquid left in the
container.
Remove the cause
of the counter
pressure.
Adjust the alarm
level.
Check the wires
and the couplings.
Damaged flow
sensor.
(Deactivating the
FLO-alarm: Set the
alarm rate to 0.)
Check the wires and
the couplings.
21