Download Print this page

Leader Light LL ANA8 User Manual

Analog module

Advertisement

Quick Links

LL ANA8 - Analog module
LL08 400
COMPLIMENTS ON YOUR PURCHASE!
All dimensions are in millimeters
107
105,4
Package includes:
-
LL ANA8
-
User manual
Additional items needed:
-
Data and power cables
-
24V DC power supply
Content:
01
SAFETY INFORMATION
01.1 Safety instructions
01.2 Operating restrictions
01.3 Fire protection
02
PRODUCT SPECIFICATION
02.1 Technical specification
02.2 Product description
03
INSTALLATION
03.1 Unpacking
03.2 Physical installation
03.3 Connection
03.4 Installation factors
03.5 DMX channels
04
MAINTENANCE AND SERVICE
ENVIRONMENTAL PROTECTION
Do not throw away the appliance with the normal household waste at the end of
its life, but hand it in at an official collection point for recycling. By doing this, you
help to preserve the environment.
©MMX - Leader Light – All right reserved
Leader Light s.r.o.
01 SAFETY INFORMATION
M.Gorkeho 33
SK-052 01 Spisska Nova Ves
Slovakia
WARNING!!!
www.leaderlight.eu
Carefully read before installing, powering or servicing. Nothing to
USER MANUAL
do if anything misunderstand! Installation can be done only by a
qualified professional in accordance with relevant local codes.
01.1 Safety instructions
-
Shut down power before installation or maintenance of equipment or
voltage /data source.
-
Do not modify, alter, or attempt to service the LeaderLight appliance. Doing
so will void the warranty.
-
Use only the recommended DC voltage source.
-
Connect the ground to the bottom of the box!
73,5
-
Electrical connections, service and maintenance can be performed only by
qualified professional.
-
AC power supply of DC power supply must comply with local regulations.
-
AC power supply must be protected against overvoltage and short circuits.
75,4
01.2 Operating restrictions
-
This product was designed for indoor use only!
-
If the product has been exposed to drastic temperature fluctuation (e.g. after
transportation), do not switch it on immediately. The arising condensation
water might damage your unit. Leave the unit switched off until it has
reached room temperature.
-
Do not operate the product in humid, dusty or too hot/cold environments.
-
Before connecting, make sure the product is not damaged, wet, or otherwise
1 pc.
damaged.
1 pc.
-
Unprofessional operation creates the most damages!
-
For transport use the original packaging.
Operate only with 24V DC stabilized source!
01.3 Fire protection
-
Follow all safety restrictions.
-
Device never cover – the minimum space around the vents must be at least
100mm (4 in.).
-
Allowed maximum ambient temperature is 40°C (104°F).
02 PRODUCT SPECIFICATION
02.1 Technical specification
Power connection:
Output:
Control data:
Ambient temp. (Ta):
Net weight:
Dimensions LxWxH:
Installation:
DC24V max. 10W
8x analog output 1-10V DC, max. 100mA
Protocol USITT DMX-512 or RS 423/232 LL defined protocol
0°C ÷ +40°C
0,36 kg
107mm x 105,4mm x 73,5mm
standard DIN installation TS35 – 6DIN
Edition: A - 2010
02.2 Product description
DIP
DC 24V
settings
power
Control data
6pin line conector
Rotating DIP
"100"
"10" "1"
D- D+
D- D+
1 2 3 4
x100
x10
x1
+24V
DMX 512
DIP
CHANNELS
POWER
MODE & ADDRESS
RS 423/232
INPUT
Leader Light s.r.o. Slovakia, 2010
S/N
DC 24V INPUT, T
:40°C
max
300mA MAX for EACH OUTPUT
OUT1
OUT2
OUT3
OUT4
OUT5
OUT6
+ - +v + - +v
+ - +v + - +v
+ - +v + - +v
8x analog output
4x 6pin line conector
Indication of control LEDs (LED power- green,LED data - yellow)
LED
Indication
Status
LED Power
blinking - 2Hz
O.K. - device is working correct
LED Data
not lit
No DMX signal
LED Data
blinking - 4Hz
O.K. - Connected the correct DMX signal
LED Data
fast blinking
ERROR - incorrect digital signal
LED Power &
alternating
function AutoTest
LED Data
blinking
03 INSTALLATION
03.1 Unpacking
-
Unpack carefully.
-
This is electronic equipment and should be handled carefully.
-
Damaged delivered package or if are any mechanical parts broken – it must
be claim immediately by the transport company. Photo pictures as evidence
are valuable for future claim.
03.2 Physical installation
-
Loading capacity of bearing area has to be at least 10 times the weight of all
device clusters.
03.3 Connection
-
Respect all SAFETY INFORMATION 01!
-
Connect the ground (earth) to the bottom of the module!
-
LL ANA8 device may be operated only with 24V DC stabilized source.
-
In the case of connecting the power supply with more than a prescribed
voltage you can suffer a dangerous electric shock, inflict damage equipment
or fire.
-
Shut down power supply from all devices before installation of LL ANA8 to
end devices.
If you have any question please, contact support@leaderlight.sk
Control
LEDs
0V
D
P
A
O
T
W
A
E
R
LL ANA8
Made in EU
www.leaderlight.eu
sales@leaderlight.eu
OUT7
OUT8
+ - +v + - +v

Advertisement

loading

Summary of Contents for Leader Light LL ANA8

  • Page 1 By doing this, you Dimensions LxWxH: 107mm x 105,4mm x 73,5mm Shut down power supply from all devices before installation of LL ANA8 to help to preserve the environment. Installation: standard DIN installation TS35 –...
  • Page 2 +100mm to each side and must be add ventilation modul. Service: For outdoor installation must be add heating modul, if the outdoor LL ANA8 is addressable analog output module. The device is designed primary temperature is less then 0°C any time! Customer service provided by the manufacturer.