1. Basic Safety Instructions for SPINNER Broadcast Products The following instructions and safety instructions are to be carefully read and followed! The Spinner group makes every effort to keep the safety standard of our products up to date to be able to offer our customers the highest possible degree of safety.
Page 4
These products must be operated only under the operating conditions specified in the product documentation. All instructions for start-up, operation and servicing listed in the product documentation have to be observed. Applicable local or national safety regulations and rules for the prevention of accidents must be observed in all work performed.
Page 5
24. All externally connected circuits for control, alarm and signalling must be supplied by SELV power sources (SELV according to DIN EN 60950-1). The current in these circuits must be limited to the values specified in the product documentation by means on an external fuse. 25.
Intended use The intended use of the product is switching over (Double Pole Double Through or Single Pole Double Through) between two coaxial paths of an RF system in indoor applications on operating sites with limited access. Details and other limits are given in the data sheet of this manual. The product may only be operated within the specifications given in the data sheet of this manual.
Bistable switching property (latching) The RF switches show a bistable switching behaviour. Switching takes place from one stable state into another after applying the control voltage. For this reason, an impulse control signal is sufficient. The minimum impulse length has to correspond to the maximum switching time (see data sheet of this manual).
Data sheet Radio frequency characteristics BN 754081: 7-16-f (50 Ω) Interface type (4 connections) BN 754082: 4.3-10-f (50 Ω) Characteristic impedance 50 Ω Frequency range 690 MHz to 2.69 GHz 3.4 to 3.8 GHz Return loss, min. 20 dB 20 dB Isolation, min.
Page 9
Environmental conditions ETSI EN 300 019-1-3 V2.3.2 (2009-1) class 3.1 N Operational conditions Ambient temperature **** -10 to +60°C Condensation Not allowed Relative humidity, max. Derating of input power with increasing altitude The maximum input power can be applied up to 500 m or 1600 ft above sea level unless noted otherwise in the data sheet.
Page 10
Max. altitude above sea level 4,000 m or 13,120 ft according to IEC EN 60664-1 Protection class III according to IEC EN 61140 IP40 according to IEC EN 60529 IP protection level (all interfaces equipped with appropriate gaskets) Installation position ETSI EN 300 019-1-2 V2.1.4 (2003-04) class 2.2 Transport conditions Ambient temperature...
Outline (all dimensions in millimeters) BN 754081: 116,34 (+10 mm to disconnect the connector) Ground connection Position indication Manual operation Threaded mounting holes 4x M4 / 6 deep on Ø75 Threaded mounting holes 2x M4 / 6 deep on both sides RF connection ±2...
Storage Keep dry and avoid exposure to sudden temperature changes to prevent condensation. Environmental conditions for storage are specified in the data sheet of this manual. Do not unpack until immediately prior to installation Do not remove any connector transportation locks until immediately prior to assembly ATTENTION to avoid damage.
Remove any dirt or metallic particles on contact surfaces before connecting. Ensure sufficient strength of all RF connections. BN 754081 (RF connection 7-16): Torque all connections to 30 Nm. BN 754082 (RF connection 4.3-10): Torque all connections to 5 Nm.
Follow the circuit diagram given in this manual and use the supplied connector only to connect interlock, signal, control and operating voltage. The interlock and signal contacts comply with the requirements for SELV (DIN EN 60950-1). The maximum permissible voltage is 42.4 V AC / 60 V DC.
CAUTION Hot surface The RF switch heats up during normal operation. Touching it may cause burns. Do not touch the RF switch while hot. Wait until completely cooled off. The operator must control the access to the hazardous area. Do not use any cleaning fluid to avoid the risk of serious injury at re-commissioning. ATTENTION Maintenance Periodic maintenance is not required.
CAUTION Hot surface The RF switch heats up during normal operation. Touching it may cause burns. Do not touch the RF switch while hot. Wait until completely cooled off. WARNING Crushing Hazard Falling objects may cause death and serious injury. Secure the RF switch against tipping or falling.
Environmental friendly usage period 表 1 有害物质名称及含量标识格式 Table 1 Marking Styles for the Names and Contents of the Hazardous Substances Hazardous Substances 有害物质 Part Name 部件名称 Hexavalent Polybrominated Polybrominated Lead Mercury Cadmium Chromium biphenyls diphenyl ethers (Pb) (Hg) (Cd) (Cr(VI)) (PBB) (PBDE) 铅 汞 镉 六价铬 多溴联苯 多溴二苯醚 Metal parts 金属零件 This table is prepared in accordance with the provisions of SJ/T 11364. 本表格依据...