  • Page 2 RoHS Directive, 2011/65/EU and 2015/863 (RoHS 3)- Compliant The Product listed above is manufactured by Endevco, Inc. and is declared to comply with the noted Product Safety and Environmental Standards when installed and operated in accordance with the Manufacturer’s instructions provided.
  • Page 3: Table Of Contents

    1.0 Table of Contents Table of Contents ..................................3 Product Description ..................................4 Materials Required ..................................4 Pre-installation Check-up ................................4 Mounting ...................................... 4 5.1. Mounting Surface ..................................5 5.2. Screw Mount .................................... 5 5.3. Adhesive Mount ..................................6 5.4. Cable ......................................
  • Page 4: Product Description

    3.0 Materials Required All the materials used in the mounting of the Model 7310A angular rate sensor are supplied with the unit in the shipping container. These materials, as shown in Figure 1, include:...
  • Page 5: Mounting Surface

    Nm). This is roughly equivalent to finger tight with the supplied wrench. The Model 7310A angular rate sensor can be mounted on either the bottom surface of the sensor, as shown in Figure 1(a), or the top surface of the sensor, as shown in Figure 1(b). The rotation arrow mark printed on the top and bottom surface of the angular rate sensor indicates the positive rotation direction.
  • Page 6: Adhesive Mount

    (Yaw, Pitch and Roll, top left of Figure 2). Same as the single unit installation in step 5.2, in triaxial installation the 3pc 7310A units can be mounted on either the top or the bottom surface of the sensor depending on the positive direction of rotation in the specific application.
  • Page 7: 6Dof Mount

    For 6DoF measurement, 3pc Model 7310A angular rate sensors and 3pc 7264 accelerometers are installed to the 7930 mounting block with 0-80 socket head screws and washers per steps 5.2 to 5.5, as shown in Figure 3.
  • Page 8: Electrical Precautions

    Grounding The case of the model 7310A angular rate sensor is not attached to circuit ground, and the cable shield is not attached to the case or to circuit ground. The recommended grounding scheme is to ground the cable shield at the power supply ground and to no other point to avoid ground loops.
  • Page 9: Recalibration

    If the unit is used under severe environments, it may be desirable to use shorter calibration intervals. Contact Endevco for local calibration facility information or return the 7310A unit to Endevco for recalibration. Endevco maintains an angular rate recalibration service with A2LA traceability in the United States.