KP-13 Keypad Wiring Instructions
The KP-13 Keypad is a 5-wire Wiegand output keypad suitable for outdoor use. It is wired to a control
panel in the same manner as a card reader (see figure 1). The KP-13-ILL is the same keypad with illumina-
tion.
The KP-13 uses the 32-bit Wiegand format: _F=pn_2_32_S_0_D_0_B1_B2_B3_B4 (required for N-1000
with 4.17 or older firmware).
This format can be entered in a text file or Terminal Mode (not required for N-500). Refer to panel installa-
tion and programming manuals for more information. As with all keypads, press the "#" key after code
entry. To clear an entry, press the "
"3" at the same time.
LED Operation. When the reader is first powered up, the green LED will remain on until after the first
valid card read. When the "M" option is enabled in the panel programming the LEDs operate as follows:
Normally, the red LED is on.
Upon valid code entry, the green LED comes on and the red LED goes off.
After the LED pulse time elapses, the green LED goes off and the red LED comes on.
Upon invalid code entry, no LED change occurs.
Grounding. The tan wire is a chassis ground. If the keypad is mounted directly on grounded metal, tie the
tan wire to the grounded metal. Tie the keypad cable shield to the control panel ground point and float
shield at keypad. If the keypad is mounted on ungrounded metal or nonmetallic material, tie the tan wire to
the keypad cable shield and connect the shield to the control panel ground point.
Wiring specifications
Figure 1. Wiring for the KP-13.
Power for the keypad can be
supplied from the control panel.
Specifications subject to change
Northern Computers, Inc.
Headquarters:
Worldwide Locations:
•
5007 S. Howell Ave.
Milwaukee, WI 53207 USA
•
Tel: +1 (414) 769-5980
•
Fax: +1 (414) 769-5989
or +1 (414) 769-5996 (Int'l)
TECHNIC
TECHNIC
TECHNIC
TECHNIC AL BULLETIN
TECHNIC
" key. To toggle illumination off and on (KP-13-ILL only), press "
*
NCI Part #
Description
NC1861/BL
6-wire 18 AWG shielded
Crawley, Sussex, United Kingdom
Tel: (44) 1293-592700 • Fax: (44) 1293-523061
Sao Paulo, Brazil
Tel: (55) (11) 826-4944 • Fax: (55) (11) 826-0649
Australia
Tel: (612) 9699-3700 Fax: (612) 9699-3101
AL BULLETIN
AL BULLETIN
AL BULLETIN
AL BULLETIN
July 1998; Rev. 2.1 (page 1 of 2)
KP-13
Black
Red
Green
White
Brown
The Blue wire remains disconnected (not used)
Tan
(Earth Ground)
•
Hong Kong
Tel: 852-2528-1897 • Fax: 852-2528 4599
•
Montreal, Quebec, Canada
Tel: 514-933-3363 • Fax: 514-933-3447
•
Moscow, Russia
Tel: (7) 095-723 2626 • Fax: (7) 095-956 5428
Maximum Distance
500 feet
(Common)
(+5VDC)
(Data 0)
(Data 1)
(LED)
•
France
Tel: 33-1-30-13-03-93 Fax: 33-1-3- 13-03-90
•
Mexico
Tel: (52) (5) 280-7890 Fax: (52) (5) 280-8555
•
Ecuador
Tel: (593) (2) 265-588/91 Fax: (593) (2) 461-379
" and
*
TD2006
Need help?
Do you have a question about the KP-13 and is the answer not in the manual?
Questions and answers