Page 3
Declaration of conformity The undersigned manufacturer: SAINT-GOBAIN ABRASIVES S.A. 190, Bd J.F. KENNEDY L- 4930 BASCHARAGE Declares that this product: CV 324 310325226 Clipper Vacuum: Codes: 310354991 is in conformity with the following Directives: • European Machinery Directive 2006/42/EC • Electromagnetic Compatibility Directive 2004/108/EC •...
- Technical specifications – Dimensions - Technical data Parameter Unit of measurement CV 324 Voltage Volts / Hz 230/50 Power rating Noise level dB(A) Capacity Inlet (diameter) 50.8 Max vacuum 21.1 Maximum air flow rate (without hose and reductions) L /s Main filter surface dm²...
TABLE OF CONTENTS Technical specifications – Dimensions………………………………………………. 3 Instructions for use………………………………………………………………………….… 5 Operator safety…………………………………………………………………………. 5 General information for using the vacuum cleaner…………………………………..5 Proper uses…………………………………………………………………………...… 5 Dust emissions into the environment………………………………………………..5 General recommendations …………………………………………………..….. 5 Vacuum cleaner description – Labels…………………………………………………6 Accessories………………………………………………………………………………...
Instructions for use Read the operating instructions and comply with the ATTENTION DANGER! important safety recommendations identified by: - Risk of fire outbreaks and explosions. The ATTENTION DANGER! vacuum cleaner can only be used when it is certain that active sources of ignition are not - Operator safety going to be vacuumed.
- Vacuum cleaner description - labels - Packing and unpacking See fig. 1. Dispose of the packing materials in compliance with the laws in force. A - Identification plate: Code of the model, - Cardboard box packing (fig. 2) technical specifications, serial number, year of manufacture Model CV 324...
- Controls and indicators (fig. 4) ATTENTION DANGER! Sockets, plugs, connectors and installation of the A - Suction motor start/stop switches extension cable must maintain the protection Each switch controls a motor. degree of the vacuum cleaner, as indicated on the B - Power supply voltage indicator light data plate.
- Shaking the main filter - At the end of a cleaning session Depending on the quantity of dust cleaned up, shake 1. Turn off the vacuum cleaner and remove the main filter by means of the knob "A" (fig. 7) when the plug from the socket.
- Filtering chamber tightness check - Filter replacement (fig. 10) If the gasket "A" (fig. 13) between the container and Before proceeding with these operations, turn off the the filtering chamber "C" fails to guarantee tightness, vacuum cleaner and remove the plug from the power proceed as follows: socket.
- Troubleshooting Problem Cause Remedy Check if there is current in the socket The vacuum cleaner does not Check if the plug and the cable are No current start damaged Contact an authorized Service Centre Shake the filter. Replace it if this is Clogged main filter not sufficient The vacuum cleaner speed...
Need help?
Do you have a question about the Clipper CV 324 and is the answer not in the manual?
Questions and answers