Contents Correct Operation ATEX Intended Use ATEX Inspection Prior to Initial Operation Classification [Zone 2] Inspection Before Starting Work Classification [Zone 1] Maximum Capacity Spark Formation Temperature Range Static Electricity Notes for Correct Operation Inspection, Maintenance & Repair Disclaimer Assembly Instructions Warning Fall Protection Variants &...
Page 3
TDAVIT Lightweight. Portable. Safe. Please read the following instructions and They apply for: It is the responsibility of the end user to adhere guidance notes carefully, before using or to the Health & Safety and accident prevention Operation, including preparation, standards and legislation valid in their respective operating the system.
Do not the overall capacity of the davit. REID Lifting’s exceed the capacity indicated on the product. representatives can provide additional advice on this if required.
TDAVIT Temperature Range Notes for Correct Operation To avoid side pull, lowering and lifting should only be carried out when the load chain forms This product can be operated in ambient dry We recommend the use of load-sensing or a straight and vertical line between the load temperatures between -10°F to 131°F (–23°...
The fall arrest device must only be attached to restrictions for use the indicated lifting point on the column. REID Lifting does not recommend that the Never walk away from the structure whilst davit is used for personnel and goods lifting at...
Inspection & Maintenance Regular Inspections The following information is based on REID Before each use inspect the assembly and all load- Lifting’s recommendations and does not remove bearing components for visual defects as per the To ensure that the product’s remains in safe...
TDAVIT Maintenance & Repair Storage & Transportation In order to ensure correct operation, the conditions When transporting the components, take note of for inspection and maintenance must be complied all the manual handling considerations. with. If any defects are found, stop using the Do not throw the product down or stack any product immediately.
(only sockets supplied Depending upon the socket type, there are a by REID Lifting are approved to be used with this The Cast & Resin Bonded sockets can be number of different installation options. If bolts...
REID Lifting. anchor should be isolated and tested individually applying the applicable tension and shear loading. Please contact REID for more details Following initial socket installation verification tests, we recommend periodic visual examination rather than overload tests for the socket or davit.
The structure is predominantly constructed from aluminum which will not rust. However, there are REID recommends the use of corrosion resistant steel components used throughout. These are tools when assembling this product to prevent the fasteners, shackles and sockets. Where there the possibility of any sparks.
The use of a socket extension is optional and the socket type may vary between a Top Mount, Side Mount, Bridge Mount, Cast In or Resin Bonded, depending on application. The T DAVIT shown is a winched version but an unwinched variant is also available.
Page 15
The use of a ladder may be required. Contact your REID sales representative for more details. Insert the T DAVIT into the socket as shown Attach the winch onto the column and secure Play out sufficient rope to thread through the with pins.
Page 16
Assembly Instructions In some circumstances the winch can be used to rotate the beam in line for the pin insertion. Rotate the beam as illustrated Insert the clevis pin to take the weight of the Secure the pin with the R-clip beam For disassembly, reverse steps 1-9...
Page 18
Assembly Instructions The T DAVIT Type VW and its constituent components are described in the image below. The use of a socket extension is optional and the socket type may vary between a Top Mount, Side Mount, Bridge Mount, Cast In or Resin Bonded, depending on application.
Page 19
Top Mount socket shown. If using a socket extension, install first. The use of a ladder may be required. Insert the T DAVIT into the socket as shown Place the beam between rollers and slide it in Insert and secure bolt and spacer as shown...
Page 20
Assembly Instructions Secure assembly with the pins supplied The rope retaining pins need to be removed Thread the rope over the sheaves before fitting the rope Reinsert pins ensuring they are secure Please refer to the Operating manual of the winch before use...
Page 22
Assembly Instructions The T DAVIT Type T and its constituent components are described in the image below. The use of a socket extension is optional and the socket type may vary between a Top Mount, Side Mount, Bridge Mount, Cast In or Resin Bonded, depending on application.
Page 23
Remove bolt and spacer at the front of the beam Thread beam trolley over the end of the beam Lock trolley with friction brake at approximately centre position Reinsert bolt and spacer ensuring they are secure Insert T Davit column into the socket...
Page 24
Present the beam to the column and insert clevis Secure the pin with retaining R-clip Rotate the beam as illustrated pin to take the weight of the beam Insert rear clevis pin Secure the pin with retaining R-clip The T Davit is now erect...
Page 25
TDAVIT Release trolley brake Use the hand chain to move the trolley along the beam...
Page 27
Variants & Options TDAVIT The list below outlines additional options When the rotational handle is attached to the Fig 1 available which can be fitted to the TDAVIT; Davit the following points must be observed: Attach the rotational handle to the column of Rotational Handle the Davit at a suitable height [Ideal position Rotational Handle...
Dimensions TDAVIT Type W Position B Radius | Position A Radius | Position B Height of Lift | Position A Position A Height of Lift | Position B Winch Position 1 Winch Position 2 Winch Position 3 Winch Position 4 Winch Position 5 Height of Pin Position 1 Height of Pin Position 2...
Page 30
Dimensions TDAVIT Type S Position B Radius | Position A Radius | Position B Height of Lift | Position A Position A Height of Lift | Position B Height of Pin Position 1 Height of Pin Position 2...
LEEA Membership - REID Lifting is a full member of the Lifting Equipment Engineers Association This product complies with the following: Quality and Safety are at the heart of the REID (LEEA membership 000897). REID Lifting Lifting ethos and we are committed to maintaining...
QUANTUM Parkway, Weston-super-Mare, BS22 6WA, United examination or test. Kingdom (CE body no.0120) in accordance All product names are trademarks of REID Lifting Ltd: with Module B of the PPE Regulation. The EC Language PORTAGANTRY PORTAGANTRY...
Product Labelling TDAVIT Marking The serial labels indicate: The product identification number The product’s unique serial number The goods’ capacity (WLL) of the device The year of manufacture The standards to which the device is approved The ATEX rating of the product (if applicable) CE Marking Insert data from serial numbers found on product into table here:...
Page 36
All information herein is copyright protected by REID Lifting Ltd. All company and product names are Trade Mark and Trade Name protected and all REID Lifting Ltd. Product IPR is protected under Patents, Patents Pending and/or Design Rights.
Need help?
Do you have a question about the T DAVIT and is the answer not in the manual?