Download Print this page
Invacare IHCSRLAS User Manual
Invacare IHCSRLAS User Manual

Invacare IHCSRLAS User Manual

Assist bar for cs bed
Hide thumbs Also See for IHCSRLAS:

Advertisement

Quick Links

1 General
1.1 Symbols
Signal words are used in this manual and apply to hazards or unsafe
practices which could result in personal injury or property damage.
See the information below for definitions of the signal words.
DANGER!
– Danger indicates an imminently hazardous situation
which, if not avoided, will result in death or serious
injury.
WARNING!
– Warning indicates a potentially hazardous situation
which, if not avoided, could result in death or serious
injury.
CAUTION!
– Caution indicates a potentially hazardous situation
which, if not avoided, may result in property damage
or minor injury or both.
Gives useful tips, recommendations and information for
efficient, trouble-free use.
This manual MUST be given to the user of the product.
BEFORE using this product, read this manual and save for future reference.
Assist Bar Installation
en For CS Bed
User Manual
IenI
2 Safety
2.1 General Guidelines
DANGER!
Risk Of Death, Injury, Or Damage
Improper use of this product may cause injury or damage.
– If you are unable to understand the warnings, cautions
or instructions, contact a healthcare professional,
dealer or technical personnel before attempting to use
this equipment.
– Do not use this product or any available optional
equipment without first completely reading and
understanding these instructions and any additional
instructional material such as user manuals, service
manuals or instruction sheets supplied with this
product or optional equipment.
Continued use of the product with damaged parts could
lead to the product malfunctioning, causing injury to the
user and/or caregiver.
– Check ALL product components and carton for
damage, and test components before use. DO NOT
use product if components are damaged or if product
is not working properly. Contact a qualified technician
or Invacare for repair.
To avoid injury or product damage:
– Set-up and Assembly instructions MUST be performed
by qualified technicians only. "Qualified Technician
Only" sections are marked accordingly.

Advertisement

loading
Need help?

Need help?

Do you have a question about the IHCSRLAS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Invacare IHCSRLAS

  • Page 1 Gives useful tips, recommendations and information for is not working properly. Contact a qualified technician efficient, trouble-free use. or Invacare for repair. To avoid injury or product damage: – Set-up and Assembly instructions MUST be performed by qualified technicians only. “Qualified Technician Only”...
  • Page 2 Fall hazard exists due to incorrect installation of bed rails Risk Of Death, Injury Or Damage – To avoid injury, ensure that the Invacare bed rails are To avoid pinching, crush and collapse hazards from bed installed correctly and securely attached to the bed deck contact with objects under the bed: while entering or exiting.
  • Page 3 Use the following table as a guide: Installer of Assist Rails must confirm the width of the bed deck prior to installation of Assist Rails. Proper measurement of bed deck width is from the outside edge to outside edge of the deck, as shown in the following diagram: Assist Rail Model IHCSRLAS IHCSRLAS-39 IHCSRLAS-42 Minimum Deck Width 36”...
  • Page 4: Installation

    Assist Bar Installation 3 Setup 3.1 Contents WARNING! Risk Of Injury Or Damage To avoid pinching, crush and collapse hazards from bed deck contact with objects under the bed: – DO NOT place any objects or let any individual underneath the bed or in between the raised bed frame components at any time. Item Description Qty.
  • Page 5 4.2 Option 1 Knob and Carriage Screw Assembly 4.3 Option 2 Cap Screw with Serrated Washer Assembly For square mounting hole only. For round mounting hole only. Insert the 5/16–18 x 3/4 Carriage Screw through the back of the frame-tab mounting hole. Insert the 5/16–18 x 1 cap screw through the 5/16 serrated washer.
  • Page 6 Assist Bar Installation 5 Usage 5.1 Assist Bar Operation WARNING! Risk of Injury or Damage To avoid patient entrapment from use of assist bar in assist (up) position: – Only use the assist position while attending to the resident. – Return the Assist Bar to the storage (down) position when unattended.
  • Page 7: After Use

    6 After Use 6.1 Pendant Storage WARNING! Risk of Injury Or Damage To avoid injury or damage from electrical shock: – Before working on any electrical part, such as the 9-pin pendant coupling, ensure the main power to the bed is disconnected and the capacitor inside the control box is fully discharged.
  • Page 8: Maintenance

    MANUFACTURED AFTER JULY 4, 1975. Sanitizing Method This warranty is extended only to the original purchaser who purchases this product when new and unused from Invacare All surfaces may be cleaned with: Continuing Care, Inc. or a dealer. This warranty is not extended to •...
  • Page 9 Notes...
  • Page 10 Notes...
  • Page 11 Notes...
  • Page 12 All rights reserved. Republication, duplication or modification in whole or in part is prohibited USA and Canada Designed by Invacare Corporation without prior written permission from Invacare. One Invacare Way Manufactured in Mexico for Invacare Trademarks are identified by ™and ®. All...

This manual is also suitable for:

Ihcsrlas-39Ihcsrlas-42