VDH ALFA 79 ST-PID User Manual

VDH ALFA 79 ST-PID User Manual

Hygrostat

Advertisement

Quick Links

User manual
ALFA 79 ST-PID
Hygrostat.
VDH doc: 080657
Software: ALFA79-ST-PID
* Installation.
On the upper side from the ALFA 79 ST-PID is shown how the sensor, supply and
relays should be connected. After power up a self test is started. If the self test is
completed the measured humidity will be shown on the display.
* Control.
The ALFA 79 ST-PID hygrostat can be controlled by four push buttons on the
front:
SET
UP
DOWN
%RH
Viewing the set points.
*
By pushing the SET key the adjusted set point can be read out. The led 'set' also
starts flashing. A few seconds after releasing the SET key, the set point
disappears and the measured value will be visible again.
* Changing set point.
Push the SET key and the set point appears in the display. Release the SET key.
Push the SET key again together with the UP or DOWN keys to change the set
point. A few seconds after releasing the SET key the set point disappears and the
measured humidity is shown again.
* Status of the Relays.
By pushing the hidden %RH key the display shows the status of the relays. The
three digits are indicating the status from the relays, hereby 0=off and 1=on. The
code 110 means that relay 1 and relay 2 are on and relay 3 is off.
Version: v1.1
File: Do080657.wpd
- viewing / changing the adjusted value and reset alarm.
- raise the adjusted value.
- lower the adjusted value.
- hidden key above the SET key.
1
Date: 13-04-2010
Range: 0/+100%RH

Advertisement

loading

Summary of Contents for VDH ALFA 79 ST-PID

  • Page 1 Range: 0/+100%RH * Installation. On the upper side from the ALFA 79 ST-PID is shown how the sensor, supply and relays should be connected. After power up a self test is started. If the self test is completed the measured humidity will be shown on the display.
  • Page 2 SET key. Pushing the UP and DOWN keys allows you to change the value of this parameter. If no key is pushed for 20 seconds, the ALFA 79 ST-PID changes to it’s normal operation mode.
  • Page 3 * Parameters ALFA 79 ST-PID Para- Description Parameter Range Default Meter value Proportional band 1..15 %RH Integration time 0..99 Seconds 0 (=off) Differential action percentage 0..100 % 0 (=off) Cycle time 0..999 Seconds Offset humidity sensor -15..+15%RH Switching offset relay 2 0..+20%RH...
  • Page 4 * Dimensions. * Connections. * Address. VDH Products BV Tel: +31 (0)50 - 30 28 900 Produktieweg 1 Fax: +31 (0)50 - 30 28 980 9301 ZS Roden Email: info@vdhproducts.nl The Netherlands Internet: www.vdhproducts.nl...