Mounting The Control Panel - Little Giant OS3 Series Owner's Manual

Oil sensing unit
Hide thumbs Also See for OS3 Series:
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION

Mounting the Control Panel

Mounting the Control Panel
1. Remove any float switch that is currently used or supplied with the
pump.
• If the float switch cannot be removed, secure it so it is always on.
2. Attach the 2 mounting flanges to the control panel enclosure.
3. Mount the control panel within 6 feet of an electrical outlet.
4. For models with an overload relay, set the relay dial to the full load
amps of the pump.
IMPORTANT: Do not plug the unit into power until the rest of the
system has been installed.
NOTE: The pump motor may start immediately if the
overload is reset.