Cecomp
Programmable 4-Wire Digital Pressure Transmitters
Ranges and Resolution
See table below. Consult factory for special engineering units.
Resolution is fixed as indicated in table.
Accuracy
Includes linearity, hysteresis, repeatability
Standard: ±0.25% of full scale ±1 least significant digit
HA option: ±0.1% FS ±1 LSD, see table below for availability
‡ -HA option not available
PSI
inHg/PSI
Res
3PSIG
‡
.001 –30V15PSIG
5PSIG
.001 –30V100PSIG
15PSIA
‡
.01 –30V200PSIG
15PSIVAC
‡
.01
inH
O
2
‡
±15PSIG
.01
85INH2OG
15PSIG
.01 140INH2OG
‡
30PSIA
.01 400INH2OA
30PSIG
.01 400INH2OVAC
60PSIG
.01 ±400INH2OG
100PSIA
‡
.1
400INH2OG
–15V100PSIG
‡
.1
850INH2OA
100PSIG
.1
850INH2OG
‡
–15V200PSIG
.1
ftH
O
2
200PSIG
.1
7FTH2O
300PSIG
.1
12FTH2O
500PSIG
35FTH2O
.1
1000PSIG
1
70FTH2O
2000PSIG
1
140FTH2O
3000PSIG
1
230FTH2O
5000PSIG
1
480FTH2O
2
oz/in
Res
700FTH2O
‡
50ZING
.01
1150FTH2O
80ZING
.1
2300FTH2O
240ZINA
‡
4600FTH2O
.1
240ZINVAC
‡
.1
6900FTH2O
±240ZING
‡
.1
mmHg
240ZING
.1
150MMHGG
480ZINA
‡
.1
260MMHGG
480ZING
.1
760MMHGA
inHg
Res
760MMHGVAC
‡
6INHGG
.001 ±760MMHGG
10INHGG
.01 760MMHGG
30INHGA
‡
.01 1600MMHGA
30INHGVAC
‡
.01 1600MMHGG
±30INHGG
‡
.01
Torr
30INHGG
.01
760TORRA
‡
60INHGA
.01
760TORRVAC
60INHGG
.01 1600TORRA
120INHGG
.1
mbar
‡
200INHGA
.1
200MBARG
–30V200INHGG
‡
.1
350MBARG
200INHGG
.1
1000MBARA
–30V400INHGG
‡
.1
1000MBARVAC
400INHGG
.1 ±1000MBARG
600INHGG
.1
1000MBARG
1000INHGG
1
2000MBARA
2000INHGG
1
2000MBARG
4000INHGG
1
bar
atm
Res
1BARA
1ATMA
‡
.001
1BARVAC
1ATMVAC
‡
.001
±1BARG
±1ATMG
‡
.001
1BARG
1ATMG
.001
2BARA
‡
2ATMA
.001
2BARG
2ATMG
.001
4BARG
4ATMG
.001
7BARA
7ATMA
‡
.001
7BARG
7ATMG
.001 –1V7BARG
–1V7ATMG
‡
.01
14BARG
14ATMG
.01 –1V14BARG
–1V14ATMG
‡
.01
20BARG
20ATMG
.01
35BARG
34ATMG
.01
70BARG
70ATMG
.01
140BARG
140ATMG
.1
200BARG
200ATMG
.1
350BARG
340ATMG
.1
MOD-TRONIC Instruments
Display
4 readings per second nominal display update rate
4 digit LCD, 0.5" H and 5 character 0.25" H alphanumeric
DRBL: Red LED backlight
Controls
SEL
TEST
Up:
Down:
mmH
O
Res
Res
2
Zero/tare function can be enabled or disabled
‡
.1
2100MMH2OG
‡
1
Calibration
‡
.1
3500MMH2OG
1
User settable pass code required to enter calibration mode
‡
.1
cmH
O
Res
All pressure and absolute models: zero, midpoint, span
2
Res
210CMH2OG
‡
.1
All vacuum models: –span, –midpoint, zero
Vacuum/pressure models: –span, zero, +midpoint, +span
‡
.01
350CMH2OG
.1
±15 psi models: –span, –midpoint, zero, +midpoint, +span
‡
.1
1000CMH2OA
1
‡
‡
.1
1000CMH2OVAC
1
Updated approximately 16 times per second
‡
.1 ±1000CMH2OG
‡
1
User scalable pressure range to correspond to output
‡
1
1000CMH2OG
1
-I: Current output, 4-20 mA DC
.1
2100CMH2OA
‡
1
‡
1
2100CMH2OG
1
1
kPa
Res
-V: Voltage output, 0-2 VDC into 5k ohm or greater
‡
Res
20KPAG
.01
‡
.001
35KPAG
.1
-BV: Bipolar voltage output (–2 - 0 - 2 V) for bipolar ranges
‡
.01
100KPAA
.1
100KPAVAC
‡
.1
.1
Power
.1
±100KPAG
‡
.1
8-24 VAC 50/60 Hz or 9-32 VDC
.1
100KPAG
.1
Gauge is on when power is on. Designed for continuous operation.
.1
200KPAA
‡
.1
DR:
.1
200KPAG
.1
DRBL:
.1
400KPAG
.1
Weight
‡
1
700KPAA
.1
9.5 ounces (approx.), shipping wt. 1 pound (approx.)
1
700KPAG
.1
Housing
1 –100V700KPAG
‡
1
F16DR: Extruded aluminum case, epoxy powder coated, ABS/
1
1400KPAG
1
polycarbonate bezel (aluminum bezel optional), front and rear
gaskets, polycarbonate label
Res
–100V1400KPAG
‡
1
‡
.1
2000KPAG
1
F16DRN: ABS/polycarbonate NEMA 4X case, rear gasket, polycar-
bonate label
.1
3500KPAG
1
‡
.1
7000KPAG
1
Connection, Material, Media Compatibility
1/4" NPT male fitting. All wetted parts are 316L stainless steel.
‡
.1
MPa
Res
‡
Overpressure, Burst, Vacuum
1
1.4MPAG
.001
Ranges using 3000 psig sensor: 5000 psig
.1 –0.1V1.4MPAG
‡
.001
Ranges using 5000 psig sensor: 7500 psig
‡
1
2MPAG
.001
All others:
1
3.5MPAG
.001
3000 psi, 5000 psi, and 4 digit ranges 112.5% full scale out-of-
Res
7MPAG
.001
range display: 1– – – or I –.–.–.–
‡
.1
14MPAG
.01
4 X sensor burst pressure rating, or 10,000 psi, whichever is less
‡
.1
20MPAG
.01
Vacuum service: ±15 psig, 15 psig, 30 psia, 100 psig, 100 psia,
‡
1
35MPAG
.01
2
Res
g/cm
Res
Under-range display (non-vacuum sensors): –Err
‡
‡
.1
200GCMG
.1
Environmental
.1
350GCMG
.1
Storage temperature:
‡
1
1000GCMA
‡
1
Operating temperature:
Compensated temperature:
‡
1
1000GCMVAC
‡
1
‡
1 ±1000GCMG
‡
1
1
1000GCMG
1
‡
‡
1
2100GCMA
1
1
2100GCMG
1
2
Res
kg/cm
Res
‡
.001
1KGCMA
‡
.001
‡
.001
1KGCMVAC
‡
.001
‡
.001
±1KGCMG
‡
.001
.001
1KGCMG
.001
‡
‡
.001
2KGCMA
.001
.001
2KGCMG
.001
.001
4KGCMG
.001
‡
‡
.001
7KGCMA
.001
.001
7KGCMG
.001
‡
.01
–1V7KGCMG
‡
.01
2.88"
.01
14KGCMG
.01
‡
.01 –1V14KGCMG
‡
.01
.01
20KGCMG
.01
.01
35KGCMG
.01
.01
70KGCMG
.01
.1
140KGCMG
.1
.1
200KGCMG
.1
.1
350KGCMG
.1
·
Brampton, ON
·
905-457-6322 or 1-800-794-5883
Division of
BSOLUTE
ROCESS NSTRUMENTS, Inc.
Select display for setup
Set output to test level when in test mode
Increase when in test or calibration mode
Decrease when in test or calibration mode
Output drive (compliance) determined by power source
6,553 counts over sensor range
6,553 counts over sensor range
±2 VDC into 5k ohm or greater
13,107 counts over sensor range
30 mA maximum
Approximately 40 mA maximum
2 X pressure range
200 psig sensors.
–40 to 203°F (–40 to 95°C)
–4 to 185°F (–20 to 85°C)
32 to 158°F (0 to 70°C)
88888
2
X X X X X
SEL
TEST
Cecomp Electronics / Made in USA
0.75"
¼" NPT
3.38" Standard
3.5" NEMA 4X
3 ft long,
4-conductor
3.0"
22 AWG
shielded
NEMA 4X
cable
Turn at hex
fitting
Turn at hex
only!
1.65"
2.0"
1220 American Way Libertyville, IL 60048
Phone:
±0.25% Test Gauge Accuracy
316 Stainless Steel Wetted Parts
Low Voltage Powered
4-20 mA or 0-2 V Analog Output
Output Test Function
F16DR
F16DRN
How to Specify
F16DR range - output - options
F16DRBL range - output - options
F16DRN range - output - options
F16DRNBL range - output - options
Range—see table at left
psi = PSI
inHg = INHG
2
oz/in
= ZIN
inH
O = INH2O
2
ftH
O = FTH2O
2
mmHg = MMHG
G = gauge reference pressure
VAC = gauge reference vacuum
A = absolute reference
If vacuum gauge requires a minus sign, please specify.
Output
Specify:
I
4-20 mA
V
0-2 V
BV
±2 V for bipolar (±) ranges only
Options—add to end of model number
High accuracy, ±0.1% FS ±1 LSD. Not available with 3
HA
psi, bipolar, absolute, or vacuum sensors, and some 3.5
digit display ranges. See table at left for availability.
PM
Panel mount, 4.1" x 4.1". Not avail. with NEMA models.
MC
Metal front cover. Not available with NEMA models.
3 ft long,
CC
Moisture resistant circuit board conformal coating
4-conductor
22 AWG
TP
Top gauge port. Not available with NEMA models.
shielded
Accessories—order separately
cable
WMPSK Wall mount power supply kit, 115 VAC/12 VDC
CD
Calibration data; 5 test points and date
NC
NIST traceability documentation, 5 points and date
Examples
F16DR100PSIG-HA:
fitting
F16DRBL–100V700KPAG: NEMA 4X, backlit display
only!
·
sales@mod-tronic.com
800-942-0315
Fax: 800-949-7502
F16DR, F16DRN
★ ★ ★ ★ ★ ★
Made
★ ★ ★ ★ ★
★ ★ ★ ★ ★ ★
★ ★ ★ ★ ★
★ ★ ★ ★ ★ ★
★ ★ ★ ★ ★
★ ★ ★ ★ ★ ★
★ ★ ★ ★ ★
in
★ ★ ★ ★ ★ ★
U S A
Quick Link
cecomp.com/xmtr
Type
Standard housing
Standard housing,
backlit display
NEMA 4X housing
NEMA 4X housing,
backlit display
torr = TORR
mbar = MBAR
mmH
O = MMH2O
bar = BAR
2
2
kg/cm
= KGCM
cmH
O = CMH2O
2
2
g/cm
= GCM
atm = ATM
kPa = KPA
MPa = MPA
100 psig, high accuracy
–100 to 700 kPa
© 02-12
·
www.mod-tronic.com
cecomp.com
Need help?
Do you have a question about the Cecomp F16DR and is the answer not in the manual?