Introduction
Multi drop cable kits allow to feed more than 1 cable through the round port in a flexible way.
This multi-outlet kit is used in combination with 30 mm ports (FIST-GCO2-BX6 and FOSC-400D5).
In case that one cable is installed day one of the installation and further flexibility is needed, to bring in 2 extra
cables later on, the MULTI2-kits can be used. In a first stage the cable is sealed together with 2 tubes; at a later
stage, additional cable can be fed through these tubes.
FIST-GCO2
I N S T A L L A T I O N
I N S T R U C T I O N

Advertisement

loading
Need help?

Need help?

Do you have a question about the FIST-GCO2 and is the answer not in the manual?

Questions and answers

Summary of Contents for CommScope FIST-GCO2

  • Page 1 Multi drop cable kits allow to feed more than 1 cable through the round port in a flexible way. This multi-outlet kit is used in combination with 30 mm ports (FIST-GCO2-BX6 and FOSC-400D5). In case that one cable is installed day one of the installation and further flexibility is needed, to bring in 2 extra cables later on, the MULTI2-kits can be used.
  • Page 2 • Abrasive paper • Installation instruction Accessories FIST-GCO2-RSK16-MC-U Cable seal kit to seal the cable onto the alu pipe. A strength member connector is included in this kit. Fix the strength member eyelet with the spacer screw. Bring the FIST-GCO2-RSK16-MC cable through the heatshrink port (multi-out) and fix the strength member.
  • Page 3 Installing a cable in a tube Position the heatshrink (multi-out) and tape the cable and tubes together (in this way the heatshrink stays in position). Cut off the top of the end cap and clean and abrade the tube and cable. Mount the multi-termination-plate and strength member eyelet.
  • Page 4 © 2017 CommScope, Inc. All rights reserved. web at www.commscope.com All trademarks identified by ® or ™ are registered trademarks or trademarks, respectively, of CommScope, Inc. For technical assistance, customer service, or to report any This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to missing/damaged parts, visit us at: CommScope products or services.