UNISENSE SulfiLogger User Manual
Hide thumbs Also See for SulfiLogger:

Advertisement

Quick Links

SulfiLogger™ User Manual
C
© 2019 - U
/
OPYRIGHT
NISENSE A
S
V
/
: 1004000
ALID FOR SERIAL NUMBERS FROM S
N
R
. 2019-11-19
EV
SulfiLogger_Manual_EN_203.pdf

Advertisement

Table of Contents
loading

Summary of Contents for UNISENSE SulfiLogger

  • Page 1 SulfiLogger™ User Manual © 2019 - U OPYRIGHT NISENSE A : 1004000 ALID FOR SERIAL NUMBERS FROM S . 2019-11-19 SulfiLogger_Manual_EN_203.pdf...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Warranty and support Warranty ........... . Recycling program .
  • Page 3: Warranty And Support

    Unisense A/S assumes no liability for damages on instruments designed for indoor use due to unintended field use or exposure to dust, humidity or corrosive environments.
  • Page 4: General Information

    GENERAL INFORMATION Thank you for choosing the Unisense SulfiLogger™ sensor - the only H S sensor on the market enabling direct measurement of hydrogen sulfide concentrations in either liquid or gas phase, easy plug’n’play installation in harsh environments such as sewer networks, and easy maintenance.
  • Page 5: Overview

    Guidance for installation of the SulfiLogger™ sensor can be found in Appendix A. This guide is relevant for sensors with serial numbers starting from S/N: 1004000. For older sensors please find the relevant guide on the SulfiLogger™ website at www.sulfilogger.com or contact Unisense. SulfiLogger_Manual_EN_203.pdf...
  • Page 6: Maintenance

    MAINTENANCE LEANING SulfiLogger™ sensors installed in wastewater environments may require regular cleaning depending on the fouling conditions. To clean the sensor, remove any accumulated rags and gently wipe the sensor head with a cloth. Use water or a mild soap if needed. For more information, please see page 7. ALIBRATION The SulfiLogger™...
  • Page 7: Operating Principles

    , and a separate measurement of the pH-value of the wastewater is necessary to calculate the total amount of dissolved sulfides in the wastewater. Please contact Unisense if you need guidance on how to find the concentration of total dissolved sulfide from the SulfiLogger™ sensor signal (only dissolved H S).
  • Page 8: Specifications

    SPECIFICATIONS ™ ULFI OGGER SENSORS SulfiLogger™ S1/X1-1020-5mgL S1/X1-1120-5mg S1/X1-1120-1000ppm X1-1220-1000ppm Pressurized Pressurized Pressurized Environment Wastewater wastewater gases gases Measurement range 0-5 mg/L 0-5 mg/L 0-1000 ppm 0-1000 ppm Water depth/ Pressure 3 barg 3 barg 10 barg Input power 20 to 30 V 20 to 30 V 20 to 30 V 20 to 30 V...
  • Page 9: Best Practices

    BEST PRACTICES ASTEWATER INSTALLATIONS When installing the SulfiLogger™ sensor in sewer networks, the following may serve as guidelines: • Hydrogen Sulfide (H S) is developed under oxygen free conditions in sewers which typically occurs in force mains (pumped sewer lines). The concentration of dissolved H S increases when the residence time and/or temperature of the wastewater increase.
  • Page 10: Troubleshooting

    For more information on this, please contact Unisense. Another option is to do grab sample analysis of wastewater and compare the results of a sulfide analysis (e.g. Clines’ method) with the measurement values of the SulfiLogger™...
  • Page 11 Please refer to the relevant chapter, and if this is still giving problems, contact Unisense. Please also note that even though the signal of the SulfiLogger™ sensor is temperature compensated, the accuracy of the sensor is highest if the calibration is done at a temperature close to the temperature of subsequent measurements.
  • Page 12: Appendix: Installation Guide

    PPENDIX NSTALLATION GUIDE SulfiLogger_Manual_EN_203.pdf...
  • Page 13 SulfiLogger_Manual_EN_203.pdf...
  • Page 14 UNISENSE UNISENSE, DENMARK www.unisense.com · info@unisense.com SulfiLogger_Manual_EN_203.pdf...