KSB AS1-M Installation, Operating And Maintenance Manual
KSB AS1-M Installation, Operating And Maintenance Manual

KSB AS1-M Installation, Operating And Maintenance Manual

Alarm switchgear

Advertisement

Quick Links

Installation, Operating and Maintenance Instructions
1/7
for Alarm Switchgear AS1-M
2331.827/03-EN
Installation, Operating, and Maintenance Manual
for
Alarm Switchgear
AS1-M
These installation, operating and maintenance
manual must be handed to the
fitter/installer/operator/service personnel
of our products together with all other relevant
documentation and user information!
The manual must be carefully stored in a safe place
along with all the other documents so that they can
be consulted whenever needed.
Jola Spezialschalter GmbH & Co. KG
Klostergartenstr. 11 • 67466 Lambrecht (Germany)
Tel. +49 6325 188-01 • Fax +49 6325 6396
contact@jola-info.de • www.jola-info.de
Date: 2015/10/04

Advertisement

Table of Contents
loading

Summary of Contents for KSB AS1-M

  • Page 1 Installation, Operating and Maintenance Instructions for Alarm Switchgear AS1-M 2331.827/03-EN Installation, Operating, and Maintenance Manual Alarm Switchgear AS1-M These installation, operating and maintenance manual must be handed to the fitter/installer/operator/service personnel of our products together with all other relevant documentation and user information!
  • Page 2: Table Of Contents

    2. Conditions for Safe Application Page 5 3. Installation, Connection, Commissioning and Maintenance, Governing Rules and Regulations Page 5 4. Installing the AS1-M Alarm Switchgear Page 6 5. Connecting Alarm Contactor M 1 (K) Page 6 6. Commissioning Page 6 7.
  • Page 3: Technical Description And Field Of Application

    (refer to Section 2 of these instructions: Excessive Discharging). A switch on the underside of the housing can be used to turn the AS1-M alarm switchgear on and off. Pressing the switch in turns the device off; releasing the switch turns the device on.
  • Page 4 M 1 (K) alarm contactor AS1-M alarm switchgear All technical parameters of the AS1-M switchgear are specified in this brochure and must be observed and followed, without exception, at all times. Applications outside the envelope of the key technical data specified are prohibited.
  • Page 5: Conditions For Safe Application

    The AS1-M alarm switchgear must not be installed in rooms that can become flooded. Exclusion of the Effects of Moisture and Humidity on the AS1-M Alarm Switchgear The AS1-M alarm switchgear must not be used in areas in which the device could be subjected to moisture and humidity.
  • Page 6: Installing The As1-M Alarm Switchgear

    If both of these checks are successful (i.e. no problems are detected), the device may then be commissioned. 7. Maintenance The AS1-M alarm switchgear and the M 1 (K) alarm contactor connected to it require no maintenance. The rechargeable battery of the AS1-M alarm switchgear must be replaced by qualified staff every 7 years at the latest, however.
  • Page 7: Repair

    Installation, Operating and Maintenance Instructions for Alarm Switchgear AS1-M 2331.827/03-EN If the alarm switchgear is used as a safety link in a system, the installation may need to be inspected and checked at designated intervals approved by the local supervisory authority.
  • Page 8 Klostergartenstr. 11 67466 Lambrecht declares that the following product, which is new and designed for use in dry rooms: Alarm Switchgear AS1-M complies with: the Directives 2006/95/EC (low voltage) and 2004/108/EC (EMC) the standard DIN EN 60730-1 (VDE 0631-1) : 2012-10.

Table of Contents