Do you have a question about the JPD-FR203 and is the answer not in the manual?
Questions and answers
Subscribe to Our Youtube Channel
Summary of Contents for Jumper JPD-FR203
Page 1
JPD-FR203 0482 Infrared Thermometer Instruction Manual Shenzhen Jumper Medical Equipment Co., Ltd Manual Version: 1.0 Date of Issue: 2018/09/18...
Page 2
No part of this document may be changed, excerpted, copied, reproduced, or imitated in any form or by any means without the prior consent of Shenzhen Jumper Medical Equipment Co., Ltd.
In case of any damage or operation problem, please contact the dealer or contact Jumper directly. You will need the following information when making your claim: device model, serial number, purchase date, and your contact information and address.
you do physical exercises or get excited. Do not use the thermometer for continuous temperature monitoring purposes. Do not immerse the thermometer into water or other liquid. Clean and disinfect the thermometer as described in the "Cleaning and Disinfection"...
Otherwise, the thermometer may be damaged permanently. During measurement, do not use a mobile phone or any other device that may cause electromagnetic interference. Do not use the thermometer in an environment where flammable anesthetic mixture with air or with oxygen, or nitrous oxide is available.
Symbol Description IPX0 Degree of protection against the Ingress of water. A personal injury or damage to the thermometer may occur if the thermometer is not used correctly. Warning Inaccurate reading or damage to the thermometer may occur if the thermometer is not used correctly. Attention Body Temperature Basics You can take a body temperature on the forehead, in the ear canal, under...
1°C each day. Product Description Overview Infrared Thermometer JPD-FR203 measures the human body or an object temperature based on the infrared energy emitted by the forehead or an object (such as milk and water). You can quickly get measurement results after pointing the temperature probe to the target.
Sounds and Backlight Instructions Range Sounds Backlight Forehead temperature A long beep Green 35.0℃-37.5℃/95.0℉-99.5℉ A long beep Orange 37.6℃-37.9 ℃/99.7℉-100.2℉ 3 short double beeps 38.0℃-42.2℃/100.4℉-108.0℉ Object temperature A long beep Green 0℃-100℃/32.0℉-212.0℉ Note: When the temperature is between 35.0℃-37.5℃(95.0℉-99.5℉), there will be a long beep and a Green backlight, Indicates normal body temperature.
Page 12
Operating Instructions/ Displayed Screen Display Description State Measuring Forehead temperature(Adult/child) Press the power button,then press the mode button, the thermometer enters the forehead mode, and the screen display Switch to adult or child measurement mode according to your measurement needs point the IR sensor to the center of the forehead.
Page 13
Operating Instructions/ Displayed Screen Display Description State In a power-on state, press the “Mode button”, the thermometer enters the Object mode. Object temperature mode See the table in displayed on the screen. the “Sounds and Point the IR sensor to the center of Backlight the object, then press and release the Instructions”...
Page 14
Operating Instructions/ Displayed Screen Display Description State In a power-on state, Press the measurement button for about 3 Silent seconds. You can switch units Switching between forehead temperature and object temperature In a power-on state, press the Mode button to switch between adult forehead temperature , child forehead temperature...
Page 15
Operating Instructions/ Displayed Screen Display Description State In a power-on state, Press the sound switch button to A long beep switch the sound on or off, a long will be sounded beep will be sounded when the sound when the sound is turned on.
Page 16
Operating Instructions/ Displayed Screen Display Description State In a power-on state, press the Memory button, Enter the memory mode. When leave memory button LCD display“01” followed by the recorded reading. Silent,the Press the “Memory button” again backlight is for the next recorded ,data 02 will be green shown, followed by the recorded reading.a maximum of 20...
Page 17
Operating Instructions/ Displayed Screen Display Description State When the memory data is queried, When the power when there is no memory data under is turned back the current serial number, the display on, a long beep, is as shown. the backlight is Remove 2 dry batteries and re-install green, then turn the power to clear all memory data.
Measuring Forehead Temperature 1. When using the thermometer for the first time, move the battery’s insulating piece away. 2. Press the Power button to power on the thermometer. 3. When measuring adults, place the switching device in the "adult" mode. When measuring children, place the switching device in "child"...
6. If no activity is detected, the thermometer will power off automatically in 10 seconds. Measuring Object Temperature Press the Power button to power on the thermometer. Press the Mode button, the thermometer enters the Object mode. The “ ” symbol is displayed on the screen. Point the thermometer probe to the center of the object, about 1-5cm away from the object surface.
It is dangerous to make a self-diagnosis or self-treatment based on the obtained measurement results. For such purposes, please consult a doctor. Notes: (1) The thermometer is suitable for an indoor environment without strong air convection between the thermometer and the target. For example, winds from a fan, an air-conditioner, or a heater.
Make sure that the batteries are installed correctly. Otherwise, the thermometer may be damaged. If the low-battery symbol is displayed on the screen, replace the batteries. Batteries of a same type should be used. Dispose the used batteries in accordance with the local environmental policies. The thermometer is shipped with batteries.
Page 22
Keep water off the lens during the cleaning process. Otherwise, the lens may be damaged. The lens may be scratched if it is cleaned with a piece of tissue paper, which might result in inaccurate readings. Do not clean the thermometer with corrosive cleansers. During the cleaning process, do not touch the lens using hard objects, do not immerse any part of the thermometer into liquid, or allow liquid to penetrate the thermometer.
thermometer and quickly dry it. Disinfect the thermometer body with a cloth slightly moistened with 75% medical alcohol. Do not use hot steam or ultraviolet radiation for disinfection. Otherwise, the thermometer may be damaged or quickly aged. It is recommended to disinfect the thermometer before and after each use.
Check regularly whether safety risks exist. Remove the batteries if the thermometer will not be used for more than two months. Troubleshooting Problem Possible Cause Solution Low battery the batteries. Change Polarities of the Make sure that the The thermometer batteries are reversed.
Specifications Product Name Infrared Thermometer Product Model JPD-FR203 Power Supply Mode Internal power supply Operating Voltage DC 3V Battery Model AAA x 2 Operating Mode Continuous operating Display Segment LCD...
DOCUMENTS. ● Portable and mobile RF communications equipment can affect Infrared Thermometer JPD-FR203. ● The Infrared Thermometer JPD-FR203 should not be used adjacent to or stacked with other equipment. Guidance and manufacturer´s declaration – Electromagnetic emission –for all equipment and systems Guidance and manufacturer´s declaration –...
Page 28
Guidance and manufacturer´s declaration – Electromagnetic immunity The Infrared Thermometer JPD-FR203 is intended for use in the electromagnetic environment specified below. The customer or the user of the Infrared Thermometer JPD-FR203 should assure that it is used in such an environment. Immunity...
Page 29
JPDFR203,including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Recommended separation distance where p is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in metres (m).
Page 30
RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the JPD-FR203 is used exceeds the applicable RF compliance level above, the JPD-FR203 should be observed to verify normal operation.
using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
Page 32
Shenzhen Jumper Medical Equipment Co., Ltd. Address: D Building, No. 71, Xintian Road, Fuyong Street, Baoan, Shenzhen, Guangdong, China Tel: +86-755-26696279 Fax: +86-755-26852035 Website: http://www.jumper-medical.com...
Need help?
Do you have a question about the JPD-FR203 and is the answer not in the manual?
Questions and answers