  • Page 1 24 Bit Digital Multiple Channel Matrix Processor WR-1, WR-2, WR-5 Remote Controls GPO General Purpose Logic Output Option Operating Manual ASHLY AUDIO INC. 847 Holt Road Webster, NY 14580-9103 Phone: (585) 872-0010 Toll-Free: (800) 828-6308 Fax: (585) 872-0739 www.ashly.com...
  • Page 2: Table Of Contents

    Operating Manual - ne24.24M Matrix Processor 1 INTRODUCTION ..........4 2 UNPACKING .
  • Page 3 Operating Manual - ne24.24M Matrix Processor 10 REMOTE CONTROL ..........18 10.1 WR-1 Volume Control .
  • Page 4: Introduction

    Protea ne24.24M will more than satisfy requirements for any zoned system requiring input/output matrixing with signal processing. Factory presets for many typical sound install applications are available on the Ashly web site as a starting point to set your own system requirements.
  • Page 5: Front Panel Features

    Operating Manual - ne24.24M Matrix Processor 4. FRONT PANEL FEATURES 4.1 RS-232 Dataport The ne24.24M has two RS-232 dataports wired in parallel, one on the front panel and one on the back, for connect- ing to a computer for software control. See section 7.3 for details on connecting to a computer. 4.2 Com LED This green LED lights for a few seconds whenever there is communication activity to the unit from a host PC.
  • Page 6: Rear Panel Features

    Operating Manual - ne24.24M Matrix Processor 5. REAR PANEL FEATURES 5.1 Input Connections Balanced input signals are connected to the ne24.24M using the included euroblock connector. A flat blade screwdriver is required to connect a stripped wire lead to the external connector piece, which is then inserted into the rear panel Euro Block receptacle.
  • Page 7: Ethernet Control Jack

    Operating Manual - ne24.24M Matrix Processor To use contact closure switching, up to eight presets (1-8) must first be defined according to the needs of the installation. To use the mic input “Push To Talk” feature, select the “Push To Talk Mic” checkbox in the Protea NE Software’s mic preamp dialog box.
  • Page 8: Data In/Data Out Connection

    Operating Manual - ne24.24M Matrix Processor 5.8 Data In/Data Out Connection The Data In and Out connectors are used for connecting the ne24.24M to the Ashly WR-5 active wall remote controller or RD-8C. 5.9 Factory Reset Switch Factory reset is used to clear all user defined preset names and control values and reset them to their original factory settings.
  • Page 9: Protea Ne Software

    7.1 How to get Protea NE Software Protea NE Software is shipped free with each new Protea ne24.24M, can be downloaded from the Ashly web site, or can be purchased directly from Ashly for a nominal handling fee.
  • Page 10: Connecting Using Ethernet

    If, on the other hand, the ne24.24M needs RS-232 control while still in a networked ethernet system using Protea NE Software, add a 24.24M (not the ne24.24M) from the <Add Item> menu in Protea NE Software and set the unit up accordingly using the self-launching older Protea System Software.
  • Page 11 Operating Manual - ne24.24M Matrix Processor 8.1c Phantom Power +48V Phantom power for condenser microphones can be provided to individual channels by checking the <+48V Phantom Power> box in the preamp block for a given channel. as a contact closure input channel engage. Off.
  • Page 12 Operating Manual - ne24.24M Matrix Processor on either side of the fre- quency center is boost or cut, whereas a larger "wider" bandwidth (lower Q) pro- duces an audible change to the overall tone of a signal. Parametric filters are best used to hunt down and elimi- nate problem feedback fre- quencies, add or remove a...
  • Page 13 Operating Manual - ne24.24M Matrix Processor An Autoleveler is a dynamics processor used to automatically boost or cut a signal to a user defined target level. TARGET LEVEL is the primary setting in an autoleveler, as it determines the desired constant level to which an input is boost or cut.
  • Page 14: Output Audio Functions

    8.1k Remote Level Control Each channel can be remotely attenuated through the back panel 0-5V Remote Level Control pins, or by an Ashly RD8C active remote attenuator connected to the 4-pin data connector on the back. The Remote Level Controls dialogue box then allows arbitrary assignment of the remote’s attenuator channels...
  • Page 15 24dB/oct Linkwitz- Riley filters are the industry standard, the easiest to use, and the filter type recommended by Ashly. Other filter types are available, but may require polarity switching or other adjustments for proper results. The following paragraphs offer a summary of the three filter types as used in the ne24.24M crossovers.
  • Page 16 Operating Manual - ne24.24M Matrix Processor Bessel These filters, as implemented on the ne24.24M, are always -3dB at the displayed crossover frequency. Bessel filters are used because they have a maximally flat group delay. Stated another way, Bessel filters have the most linear phase response.
  • Page 17: Other Software Functions

    Operating Manual - ne24.24M Matrix Processor 8.2f Output Compressor/Limiter A full function compressor/limiter is included on each out- put channel. A limiter is commonly used to prevent transient audio signal spikes from damaging loudspeakers, manage ana- log and digital recording levels, optimize broadcast levels, or "thicken"...
  • Page 18: Copying Settings To Another Input Or Output

    10 REMOTE CONTROL Ashly makes three remote control options for the Protea ne24.24M. All of them are designed to be installed in a standard wall mount electrical box using a standard cover plate. The WR-1 and WR-2 are passive controls which can adjust volume or select presets respectively, while the WR-5 (replaces WR-3 and WR-4) is an active control with user defined function buttons and LED display.
  • Page 19: Contact Closure Preset Recall

    Level control is "attenuate only" meaning that the maximum setting of the control potentiometer (fully clockwise) results in 0 dB gain of the controlled channel. A label template can be found on the Ashly website for printing input or output channel names under control of the WR-1 and sliding the paper behind the mylar overlay windows.
  • Page 20 Are Wired To Ch. 1 Gnd/+5 On WR-1 PCB. CV-2 CV-1 CV-1 To Pin 1-8 CV-2 To Pin 1-8 WR-2 Wiring Diagram ASHLY WR-2 Connector on 24.24M Back Panel To Pin 1-8 for Preset Recall Common* Common* *Wired Together On WR-2 PCB.
  • Page 21: Gpo Logic Output Wiring

    LEDs on the ethernet jack showing activity? If using RS-232, is the RS-232 cable properly installed to the PC? Is the software communications enabled using a 24.24M object instead of ne24.24M? This is necessary so that the older Protea System Software can be launched from within Protea NE Software for use with RS-232 applications. Is the software device set to 24.24M? Check the security level (section 9.3).
  • Page 22: Specifications

    Operating Manual - ne24.24M Matrix Processor 14. SPECIFICATIONS INPUT ....Active Balanced, 18 kohms Max Input Level: ..+20 dBu Input Gain Range: ..-50dB to +12dB, polarity select OUTPUT: .
  • Page 23: Typical Applications

    Operating Manual - ne24.24M Matrix Processor 16. TYPICAL APPLICATIONS 16 Input by 8 Output Boardroom System • Shown with three input and one output expansion cards (four channels per card) • Autoleveling and gating for worry-free automatic level control • +48V Phantom power •...
  • Page 24 Ballroom 2 AV Input Portable Mixer Output Switched Ground To Desired Pin for Mute All Function Emergency Alarm System ASHLY AUDIO INC. 847 Holt Road Webster, NY 14580 Phone: (585) 872-0010 Fax: (585) 872-0739 Outputs Subs Under Balcony (Delay) Lobby...