Quick Links

gas MUST be evacuated from the system before starting repairs.
Installation, usage and maintenance of this product must be in
compliance with all RegO
and provisions of NFPA #54, NFPA #58, DOT, ANSI, all applicable
federal, state, provincial and local standards, codes, regulations
and laws.
Inspection and maintenance on a periodic basis is essential.
Be sure all instructions are read and understood before installation,
operation and maintenance. These instructions must be passed
along to the end user of the product.
RegO Rail Tank Car equipment is AAR approved. If repaired, the
continued validity of the AAR approval is contingent upon proper
inspection to determine what needs to be repaired; proper repair
using RegO OEM parts and procedures, proper testing for leakage
and performance following repairs and installation.
ECI EXPRESSLY DISCLAIMS ANY AND ALL LIABILITY – UNDER
ANY THEORY, WHETHER CONTRACT, WARRANTY, TORT OR
OTHERWISE – RELATING IN ANY MANNER TO ANY RAIL TANK
CAR EQUIPMENT REPAIRED USING ANY PRODUCTS NOT MANU-
FACTURED BY ECI.
USE OF ANY PRODUCTS NOT MANUFACTURED BY ECI TO REPAIR
ANY RAIL TANK CAR EQUIPMENT WILL INVALIDATE ANY AND ALL
WARRANTIES OF THE RAIL TANK CAR EQUIPMENT, WHETHER
EXPRESS OR IMPLIED.
CAUTION: Contact or inhalation of liquid propane, ammonia and
their vapors can cause serious injury or death! NH
must be released outdoors in air currents that will insure disper-
sion to prevent exposure to people and livestock. LP-Gas must be
kept far enough from any open flame or other source of ignition to
prevent fire or explosion! LP-Gas is heavier than air and may not
disperse or evaporate rapidly if released in still air.
WARNING:
Installation, dis-
assembly, repair and main-
tenance MUST be performed
only by qualified personnel. All
instructions as well as requirements
®
3
A8890S-50 Series Rebuild Kit
for A8890S and A8890W Series
Railcar Pressure Relief Valves
and LP-Gas
10
R E G O
Y E A R
WARRANTY

Advertisement

loading
Need help?

Need help?

Do you have a question about the A8890S-50 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Rego A8890S-50 Series

  • Page 1 These instructions must be passed along to the end user of the product. RegO Rail Tank Car equipment is AAR approved. If repaired, the continued validity of the AAR approval is contingent upon proper inspection to determine what needs to be repaired; proper repair using RegO OEM parts and procedures, proper testing for leakage and performance following repairs and installation.
  • Page 2 Stem reassembly & testing Stem Guide 5/16” Hex Head Cap Screw (2) Rain Cap and Cable & Tie Assembly* * These items form the A8890S-50 Series Kits, recommended for rebuilds. (Not Shown) ** Must be ordered separately from RegO ®...
  • Page 3 of the 5/16” cap screws. Install seat clamp and secure with the Fill spring guide with water and observe pressure gauge as 5/16” cap screws, turning clockwise, torque 150-160 in-lbs. pressure is raised. After pressure is raised to within 25 psi of the set pressure marked on the valve, begin to increase Coat the o-ring seat area on stem with lubricant (do not get...
  • Page 4 Inspect all retained parts for signs of wear and deterioration. Re- install in the upper poppet. place parts as necessary. Install upper poppet and o-ring onto stem and lower poppet Remove and discard cable and tie assembly from the 5/16” assembly and secure with the 3/4”...