Notes During Assembly
Use a soft platform below the parts to avoid scratches and damages.
Please note you install the panels with the UV protected side out (marked with "THIS SIDE OUT")
41*
remove plastic sticker as panels are locked in place.
Product dimensions can be adjusted to your specific needs:
1. The wall -mounting profile (top -back) can be adjusted from 266 to 300 cm (104.7" to 118.1") above ground.
The adjusting is done when measuring and drilling (Step 5).
Please note the installation recommendations' height suggested in Diagram A.
Please note that the product appearance may slightly change as a result, however snow load weight does not change.
2. Poles distance from the wall can be adjusted from 160 to 210 cm (63" to 82.5") as suggested in Diagram B1.
Poles distance from the side edges can be adjusted from 5 to 54 cm (2" to 21.3") as suggested in Diagram B2.
The adjusting is done after assembly and before anchoring (Step 17) by sliding poles and profile 8189+8190 at the roof profiles'
channels.
3. Wall mounting and distance from the wall determine the roof angle and the total depth of the product (distance of gutter from the
wall). Higher wall mounting and shorter distance between wall and poles increase the roof angle and shorten the total depth
a s suggested in Diagram C.
Steps
Step 5: It is important to plan the installation area, mark as per the instructions and level the surface prior to the assembly.
Make sure you use suitable screws and anchors.
Step 8: Apply silicone sealants above beam 8185, in order to prevent water from seeping in.
Step 10: Make sure that the angle between the back wall profile and the panel supporting profiles is 90 degrees.
Step 12: Please note you install the panels with the UV protected side out (marked with "THIS SIDE OUT")
remove plastic sticker as panels are locked in place.
Step 15: Apply silicone sealants on the inner part of 7997, and connect to the profile as depicted in drawing 15a.
Step 15c: Do not tighten screw 4043 yet, in order to allow the final adjustments done in step 16b.
Step 17a+1 7c: Please adjust the poles (inside out and sideways) by sliding them to their final position prior to anchoring.
Make sure that the poles distance from the Patio cover side edge does not exceed 54 cm/21.3".
Step 17b: Adjust the gutter head's angle according to your needs and tighten screws 4043.
Step 19: Anchoring this product is essential to its stability and rigidity. It is required to complete this stage in order for your
warranty to be valid.
*Tighten all screws when completing assembly.
Note:
The wall anchoring kit supplied with this product is suitable for concrete or solid brick walls
only. Other wall types need an accordant wall fixation kit.
266-300cm
104.7"-118.1"
160 cm -210 cm
63"- 82.5"
CIE
C.)
5 cm -54 cm
2"- 21.2"
1=11=1
B2
5 cm - 54 cm
Z-21.2"
10°