Single-temperature single-zone hydronic unit with 160-litre storage tank unit
Hide thumbs Also See for BASIC MAGIS PRO:
Table of Contents

Advertisement

Available languages

Available languages

SOLAR HEATING SYSTEM COUPLING KIT
installation operations.
- Close the cold water inlet upstream of the
system and empty the storage tank unit.
- Disconnect power supply.
- Fix the support bracket (2) for the clip (4) to
the hydraulic unit (A) using the screw (3), (Fig.
27).
- Assemble the plate heat exchanger (5) to the
solar unit (1) by hanging it in the appropriate
seat and securing it with the supplied screw (3),
(Fig. 26).
- Couple the solar unit (1) to the hydraulic unit
(A) by hanging it to the two appropriate seats,
then secure it with the supplied screws (3), (Fig.
26).
- Stop the expansion vessel using the clip (4) that
must be wrapped around it and passed behind
the special bracket (2).
- Make the hydraulic connections of the kit (Fig.
28).
- Remove the two caps present on the storage
tank unit make the connections of the relative
pipes (UCS and EFS).
- Connect the interception cock (6) on the plate
heat exchanger by interposing the relative flat
gasket / seal.
- Following the sequence below, connect all the
pipes taking care to interpose the flat gaskets
present in the kit, pipe RP - MP (long) - UCS
- RP (short) - EFS.
- Connect the two solar system pipes to the
specially arranged fittings, using one of the
pre-cut slots (B).
- Fit the fitting of the safety valve. Connect the
silicone pipe (8) to the fitting and insert it in
the can (7).
- Insert the solar storage tank / cylinder probe
(9) in the appropriate seat.
- Re-open the cold water inlet and power supply
the system again.
26
1
3
5
27
3
1
3
3
64
A
4
3
3
2
3