ABLE OF ONTENTS Model Description .............................. 1 Features ..................................1 Intended Use ................................1 Warranty ..................................2 Initial Setup ................................. 2 Quick Start ................................3 Settings ................................4 Review Cycle Time and Speed Settings........................4 Changing Cycle Time and Speed Settings ........................4 Operation ................................
ODEL ESCRIPTION The DASH Coag centrifuge is engineered to reduce turnaround time (TAT) and simplify coag processing in the STAT laboratory. Produce error-free samples in as little as 3 minutes with the DASH Coag’s simple set-and-lock controls, preset cycle settings, and an LED lid lighting indicator system.
ARRANTY Drucker Diagnostics warrants that this centrifuge is free from defects in workmanship and parts for 2 years. WARNING: For the safety of both the operator and service personnel, care should be taken when using this centrifuge if handling substances that are known to be toxic, radioactive or contaminated with pathogenic microorganisms.
Two beeps will confirm that cycle selection is locked. To re-enable cycle selection, press and hold the UNLOCK button for Unlock Cycle Selection 5 seconds. Three beeps will confirm that cycle selection is now unlocked. Drucker Diagnostics – Customer Service: +1-814-692-7661 – CustomerService@DruckerDiagnostics.com | Page 3...
Move to speed setting mode by pressing the UNLOCK button. o Press the START button once for each 100 rpm. o Press the UNLOCK button to exit setting mode. Drucker Diagnostics – Customer Service: +1-814-692-7761 – CustomerService@DruckerDiagnostics.com | Page 4...
Opposing tube holders must be equally loaded or empty or loaded with equally weighted samples. When loading only 3 tubes, they must be of equal weight. Drucker Diagnostics – Customer Service: +1-814-692-7661 – CustomerService@DruckerDiagnostics.com | Page 5...
Pull the mechanism towards the control panel and then unlatch and open the lid. o If the unit is damaged, contact your authorized dealer or Drucker Diagnostics. Drucker Diagnostics – Customer Service: +1-814-692-7661 – CustomerService@DruckerDiagnostics.com | Page 7...
Page 14
Clicking noise during braking gets loud o Make sure that the screw in the center of the rotor is tight. Lid does not stay up o Tighten the center screw on the lid hinge. Drucker Diagnostics – Customer Service: +1-814-692-7761 – CustomerService@DruckerDiagnostics.com | Page 8...
In Inches: RCF or G-force = 0.00001118 x RCF or G-force = 0.0000284 x Rotor Radius (cm) x (RPM) Rotor Radius (in) x (RPM) Radius 3.5 in (9 cm) Drucker Diagnostics – Customer Service: +1-814-692-7661 – CustomerService@DruckerDiagnostics.com | Page 9...
Page 16
Complies with UL61010-1/CSA C22.2 No. 61010-1 and IEC61010-2-020 Protected by U.S. Patents #6,811,531, #D718,463, & #D734,489. Other Patents Pending RoHS FDA LISTED Compliant INSTRUCTIONS FOR DISPOSAL OF WEEE BY USERS IN THE EUROPEAN UNION This product must not be disposed of with other waste. Instead, it is the user’s responsibility to dispose of their waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment.