Automated Beverage System
Troubleshooting
Problem
Not enough ice in the cup.
Ice will not dispense.
Drinks too foamy.
Won't pour drinks.
54
Probable Cause
A. Ice bin empty.
B. Defective gate cylinder.
C. CO2 supply disconnected or
depleted.
D. Agitator motor defective or wired
incorrectly.
A. Ice bin empty.
B. Defective gate cylinder.
C. CO
supply disconnected or
2
depleted.
D. Agitator motor defective or wired
incorrectly.
A. Carbonator pressure too high.
Normal operating range should be
80 - 100 P.S.I.
A. Cup tubes empty.
© 2004 -2018 The Coca-Cola Company, Cornelius and
Corrective Action
A. Fill ice bin.
B. Call for service.
C. Reconnect CO
.
2
Replace CO
cylinder.
2
Call for refill (bulk)
Call for service
D. Call for service.
A. Fill ice bin.
B. Call for service.
C. Reconnect CO
.
2
Replace CO
cylinder.
2
Call for refill (bulk)
Call for service
D. Call for service.
A. Call for service.
A. Refill cup tubes with correct
cups.
McDonald's Corporation. All Rights Reserved.
Need help?
Do you have a question about the CORNELIUS AUTOMATED BEVERAGE SYSTEM and is the answer not in the manual?