Gifas-electric FONTO 2290 Manual

Gifas-electric FONTO 2290 Manual

Floor socket outlets

Advertisement

Quick Links

Floor socket outlets FONTO
Floor socket outlets FONTO
Manual
VERSION
MODIFICATIONS
1.0
Creation of the document
1.1
More detailed information in chapter 3 and 4
1.2.
Complement chapter 4 (07.02.2020 roen)
1.3.
Complement FONTO 8000 (08.07.2020 roen)
Created
Modified
12.12.2016
08.07.2020
KHSH
roen
Object-ID
1144626
Page 1 / 18

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FONTO 2290 and is the answer not in the manual?

Questions and answers

Summary of Contents for Gifas-electric FONTO 2290

  • Page 1 Floor socket outlets FONTO Floor socket outlets FONTO Manual VERSION MODIFICATIONS Creation of the document More detailed information in chapter 3 and 4 1.2. Complement chapter 4 (07.02.2020 roen) 1.3. Complement FONTO 8000 (08.07.2020 roen) Created Modified Object-ID Page 1 / 18 12.12.2016 08.07.2020 1144626...
  • Page 2: Table Of Contents

    Introduction ..........................4 Disposal of the device ..................... 4 Technical data ......................... 4 Installation conditions ...................... 5 Installation examples FONTO ....................6 FONTO 2290 ........................6 FONTO 2295 ........................6 FONTO 3290 ........................7 FONTO 3295 ........................7 FONTO 3301 ........................8 FONTO 3308 ........................
  • Page 3: General Information

    Floor socket outlets FONTO 1 General information 1.1 Marking concept for hazards and hints Hazard Hazardous situation which will cause serious injury or even death if it is not prevented. Caution Hazardous situation which could cause slight to moderate injury if it is not prevented. Hint Indicates information which does not concern personal injury, e.g.
  • Page 4: Introduction

    Floor socket outlets FONTO 2 Introduction To ensure proper installation, the following steps and notes must be complied with under all circumstances. Only this way can it be ensured that the product will work to complete satisfaction. Hint Read all instructions before starting installation. Our sales department will be happy to answer any questions you may have.
  • Page 5: Installation Conditions

    Floor socket outlets FONTO 2.3 Installation conditions GIFAS-ELECTRIC GmbH accepts no liability in cases where the product has been used inappropriately or not as intended. The selection and use of the product are the exclusive responsibility of the individual operator.
  • Page 6: Installation Examples Fonto

    Floor socket outlets FONTO 3 Installation examples FONTO 3.1 FONTO 2290 1. Floor covering 2. Backfill 3. 2x cable gland M25 (across) 4. Mortar bed to align 3.2 FONTO 2295 1. Floor covering 2. Backfill 3. 2x cable gland M25 (beside) 4.
  • Page 7: Fonto 3290

    Floor socket outlets FONTO 3.3 FONTO 3290 1. Floor covering 2. Backfill 3. 2x cable gland M25 (beside) 4. Mortar bed to align 3.4 FONTO 3295 1. Floor covering 2. Backfill 3. 2x cable gland M25 (beside) 4. Mortar bed to align 5.
  • Page 8: Fonto 3301

    Floor socket outlets FONTO 3.5 FONTO 3301 1. Floor covering 2. Backfill 3. 2x cable gland M25 (beside) 4. Mortar bed to align 5. 2x cover cable outlet Hint The cover is removable. 3.6 FONTO 3308 1. Floor covering 2. Backfill 3.
  • Page 9: Fonto Series 4000

    Floor socket outlets FONTO 3.7 FONTO series 4000 1. Floor covering 2. Backfill / under floor 3. 2x cable gland M25 4. 4x levelling feet M8 FONTO 4290 FONTO 4295 FONTO 4301 FONTO 4308 5. Cover cable outlet 6. Recessed lid for floor covering Hint FONTO 4290 / 4295 closed IP20 FONTO 4290 / 4295 hinged cover...
  • Page 10: Fonto 8000

    Floor socket outlets FONTO 3.8 FONTO 8000 (level-adjustable after installation approx. +/- 6mm) 240mm 1. Floor covering 2. Backfill / under floor 3. 3x cable gland M25 4. 4x levelling feet M8 5. Cable outlet on cover Hint FONTO 8301 removable cover FONTO 8308 removable cover / for various floor coverings...
  • Page 11: Fonto 1970D

    Floor socket outlets FONTO 3.9 FONTO 1970D 1. Floor covering 2. Backfill 3. 2x cable gland M25 (across) 4. Mortar bed to align Special: screwable lid 3.10 FONTO 1970W 1. Floor covering 2. Backfill 3. 2x cable gland M25 (underside of the housing) 4.
  • Page 12: Fonto 3970W

    Floor socket outlets FONTO 3.11 FONTO 3970W 1. Floor covering 2. Backfill 3. 2x cable gland M25 (beside) 4. Mortar bed to align 5. Silicone joint 6. Water height maximum 20 mm 3.12 FONTO 1975 1. Floor covering 2. Backfill 3. 2x cable gland M25 (across) 4.
  • Page 13: Installation Examples Fonto Levelable

    Floor socket outlets FONTO 4 Installation examples FONTO levelable 1. position the floor socket and fix the levelling feet (option) 2. Level the upper edge of the floor socket to the ground surface 3. Lay pipes or cables 4. Put on the protection cap (part of the packaging) 5.
  • Page 14: Connection / Handling Floor Sockets Fonto

    Floor socket outlets FONTO 5 Connection / Handling floor sockets FONTO Opening of floor outlet i.e. removal of the insert holder: 1. Open the cover of the junction box. 2. Unscrew the insert holder. 3. Pull out insert holder. 4. Connect the sockets. The replacement and closing takes place in reverse order.
  • Page 15: Fonto 1970W

    Floor socket outlets FONTO 5.1 FONTO 1970W to open to fix 5.2 FONTO 3970W Created Modified Object-ID Page 15 / 18 12.12.2016 08.07.2020 1144626 KHSH roen...
  • Page 16: Fonto 1975

    Floor socket outlets FONTO 5.3 FONTO 1975 Opening of floor outlet i.e. removal of the insert holder: 1. Unscrew the cover with an allen Key (size 5) counterclockwise. 2. Extract the water protection tube. 3. To connect the sockets you have to remove the 4 pc. screws at the insert holder (allen Key size 3) 4.
  • Page 17: Handling Fonto 175

    Floor socket outlets FONTO 5.3.1 Handling FONTO 175 Created Modified Object-ID Page 17 / 18 12.12.2016 08.07.2020 1144626 KHSH roen...
  • Page 18: Service

    CH-9424 Rheineck www.gifas.ch Technical changes and errors reserved. These installation instructions are the property of GIFAS-ELECTRIC GmbH and may not be copied, tran- slated, transferred, duplicated or passed on to third parties without the previous written consent of GIFAS- ELECTRIC.