Summary of Contents for Flowserve IPS Smart RTU
Page 1
USER INSTRUCTIONS IPS Smart RTU Installation Operation Maintenance Multiple Sensor Input and Wireless Transmitting Unit PCN = 26999987 6-14 (E). Original Instructions These instructions must be read prior to installing, operating, using and maintaining this equipment. 701-4101-01^...
IPS SMART RTU ENGLISH 701-4101-01^ 6-14 9.2 I ....... 19 CONTENTS NACCURATE OR ISSING 9.3 N VB-103-TAM ... 19 ECORDED ON 1 INTRODUCTION AND SAFETY ......3 9.4 N IGHTS ON IGHTS OR ISPLAY ..........19 CCESSORIES 1.1 G ............3 ENERAL 1.2 CE M...
Information in these User Instructions is believed to be complete and reliable. However, in spite of Flowserve is committed to continuous quality all of the efforts of Flowserve Corporation to improvement and being at your service for any provide comprehensive instructions, good...
Flowserve before start Always coordinate repair activity with operations and health and safety personnel, and follow all plant safety requirements and applicable safety and 1.6 Safety...
Humidity: 50% at 104°F (40°C) and/or damage must be reported immediately to Power requirement: 24VDC, 110VAC or Flowserve and must be received in writing within 220VAC ten days of receipt of the equipment. Later claims Channel output 24VDC cannot be accepted.
3 DESCRIPTION After unpacking, protection will be the responsibility The IPS Smart RTU model is a wireless of the user. transmitting unit designed to monitor multiple analog, discrete or IPS Wireless sensor inputs and 2.4 Recycling and end of product life...
IPS SMART RTU ENGLISH 701-4101-01^ 6-14 At the pre-configured transmission time, the Smart 2. Vibration Sensor RTU reads the sensor data on a single channel, 3. Temperature Sensor (RTD) transmits it and the moves on to the next channel 4. Temperature Sensor (Thermocouple) until all the channels have been read and data 5.
IPS SMART RTU ENGLISH 701-4101-01^ 6-14 complete list of the different configurations data from all sensors at the preconfigured log available for the Smart RTU. interval. Data from the VB-103-TAM and the log interval can be reviewed utilizing an IPS Dock 3.2 Default Configuration...
IPS SMART RTU ENGLISH 701-4101-01^ 6-14 provides a visual light indication if any sensors on The Smart RTU can also be turned off when not in the Smart RTU unit are or have been in alarm use for extended periods of time to conserve status.
IPS SMART RTU ENGLISH 701-4101-01^ 6-14 Power is provided by a sealed lead acid 12V battery located inside the Smart RTU enclosure. 5 CUSTOM CONFIGURATION The battery is then charged by either a solar panel PROGRAMMING or an AC power supply (dependent on specific unit).
IPS SMART RTU ENGLISH 701-4101-01^ 6-14 5. Ensure the receiver is receiving data from the unit. If applicable, let the VB-103-TAM log data 6.1 Tools required for a few minutes and confirm appropriate light Tools required to install the various...
IPS SMART RTU ENGLISH 701-4101-01^ 6-14 Figure 5: Outside of bottom portion of Smart RTU enclosure with conduit going into penetrations in enclosure Figure 6: Sample installed solar powered Smart 6.5 Mounting Each unit should be clear of physical obstructions to the receiver and/or repeater(s) in order to 6.6 Connecting Sensors and Power-Up...
IPS SMART RTU ENGLISH 701-4101-01^ 6-14 Individual Sensor Information Display(s) (RTU-SID- For a 4-wire 4-20mA device, connect wires as X) are already installed on the Smart RTU unit if follows: ordered. They do not require any further Connect positive of sensor wire to installation or configuration.
IPS SMART RTU ENGLISH 701-4101-01^ 6-14 7.2 Drawings Figure 8: AC Powered Smart RTU drawing flowserve.com Page 14 of 24...
Page 15
IPS SMART RTU ENGLISH 701-4101-01^ 6-14 Figure 9: Solar Powered Smart RTU flowserve.com Page 15 of 24...
Page 16
IPS SMART RTU ENGLISH 701-4101-01^ 6-14 Figure 10: Smart RTU with RTU-OVAL, RTU-SAL and RTU-SID accessories flowserve.com Page 16 of 24...
Page 17
IPS SMART RTU ENGLISH 701-4101-01^ 6-14 Figure 11: Inside of Smart RTU with RTU-OVAL, RTU-SAL and RTU-SID accessories flowserve.com Page 17 of 24...
IPS SMART RTU ENGLISH 701-4101-01^ 6-14 on if your unit has a solar panel or AC power input. 8 CERTIFICATIONS AC Power: confirm the voltage coming out of the 24V power The following certifications are applicable to the Smart supply is close to 24VDC. If there...
IPS SMART RTU ENGLISH 701-4101-01^ 6-14 If data is being read from this location, then ensure Low battery on VB-103-TAM that the repeater network is appropriately located Incorrect VB-103-TAM log interval and functional. configuration 9.1.4 Receiver Not Configured Correctly 9.3.1 Incorrect/Loose Sensor Cable...
Page 20
IPS SMART RTU ENGLISH 701-4101-01^ 6-14 below 11V, replace the battery according to instructions in section 4 MAINTENANCE. 3. If communications are still not successful, confirm the power source being used to charge the battery. This procedure will vary depending on if your unit has a solar panel or AC power input.
Page 21
IPS SMART RTU ENGLISH 701-4101-01^ 6-14 10 DECLARATION OF CONFORMITY (TYPICAL) Flowserve Corporation 10920 West Sam Houston Parkway North Suite 950 Houston, Texas 77064 Declare in sole responsibility that the equipment: ELD-102-X Single Point Transmitters SELD-103-X Smart Point Transmitters ELD-FA-403-Receiver, AO/DO and Serial Modbus...
Page 22
IPS SMART RTU ENGLISH 701-4101-01^ 6-14 Declaration of Conformity ATEX Directive 94/9/EC + all amendments Basis for compliance: The equipment has been assessed using the following standards and is supported by the following technical documents: EN 60079-0 2006 Electrical apparatus for explosive gas atmospheres Part 0 (+ corr.
Page 23
IPS SMART RTU ENGLISH 701-4101-01^ 6-14 The technical documentation required to demonstrate that the product meets the requirements of the Directives has been compiled by the signatory below and is available for inspection by the relevant enforcement authorities. Signed: _____________________________________________...
Page 24
IPS SMART RTU ENGLISH 701-4101-01^ 6-14 Your Flowserve factory contacts: FLOWSERVE REGIONAL Flowserve Corporation SALES OFFICES: 10920 W Sam Houston Parkway N, Suite 950 Houston, TX 77064 USA USA and Canada Phone: +1 832 375 0807 Flowserve Corporation Pump 5215 North O’Connor Blvd.,...