  • Page 1 User Instruction Manual Oxford Mermaid & Ranger ® To avoid injury, read user manual prior to use. For alternative languages, contact your authorised service provider.
  • Page 2: Table Of Contents

    2. About Your Lift ....................4 3. Side and End Fit Illustrations ................5 4. Assembly and Installation Instructions ............. 6 5. Oxford Mermaid Electric Illustration ..............8 6. Fitting Dimensions ................... 9 7. Assembly and Installation Instructions ............10 8.
  • Page 3: Statement Of Intended Use

    Oxford patient lifts should only be operated by fully trained/competent care givers. Minimum Expected Life Oxford Mermaid and Ranger products are designed and tested for a minimum service life of seven (7) years, subject to the use and maintenance procedures in this manual. Use other than in accordance with these instructions may compromise service life.
  • Page 4: About Your Lift

    Servicing and periodic testing can be carried out by your supplier. Please ensure your lift is included in their maintenance schedule. The Oxford Mermaid & Oxford Ranger are suitable for Category C - Bath within the working parameters of the lifts specified in the TECHNICAL SPECIFICATIONS.
  • Page 5: Side And End Fit Illustrations

    Oxford ® English Mermaid & Ranger 3. Side and End Fit Illustrations 1. Left hand side fit 2. Right hand side fit 3. End fit...
  • Page 6: Assembly And Installation Instructions

    ® English Mermaid & Ranger 4. Assembly and Installation Instructions Models: • Oxford Mermaid • Oxford Ranger • Oxford Electric Mermaid • Oxford Electric Ranger Oxford bath lifts are supplied with a universal base plate. Concrete floors and wooden floors require different fixing kits.
  • Page 7 Oxford ® English Mermaid & Ranger Oxford Mermaid Electric 1st carton: • MAIN MAST ASSEMBLY (15kgs) • UNIVERSAL BASE PLATE (5kgs) • HAND CONTROL • POWER PACK • CHARGER • CONCRETE / WOOD FLOOR FIXING KIT • SEAT SUPPORT ARM (2.3kgs) •...
  • Page 8: Oxford Mermaid Electric Illustration

    Oxford ® English Mermaid & Ranger 5. Oxford Mermaid Electric Illustration...
  • Page 9: Fitting Dimensions

    Oxford ® English Mermaid & Ranger 6. Fitting Dimensions End Fitting: Side Fitting: Mermaid Commode Ranger Mermaid Commode Ranger 850mm 810mm 810mm 865mm 815mm 890mm 430mm 430mm 430mm Universal Base Plate Principle Dimensions:...
  • Page 10: Assembly And Installation Instructions

    CAUTION It is recommended the installation is performed by a Joerns Healthcare approved dealer or competent person. 1. Remove all the parts from the carton and place on the floor, taking care to protect the finish from damage.
  • Page 11: Installation Of The Base Plate

    Oxford ® English Mermaid & Ranger 8. Installation of the Base Plate Concrete Floors: Establish with your architect the structural integrity of the concrete floor, bearing in mind the stresses imposed by the Mermaid. In brief, a sound floor of at least 120 - 150mm thickness of good concrete is ideal.
  • Page 12: Wooden Floor Installation Kit

    Oxford ® English Mermaid & Ranger 9. Wooden Floor Installation Kit Two steel bars are provided for the safe installation of the bath lift to wooden floors. The bars should be used as follows: MERMAID BASE PLATE STEEL BAR All three holes in the base plate should be used, with one bar spanning either ‘A’ or ‘B’ and the other bar bolted through the third hole.
  • Page 13: Testing Of Installation

    Oxford ® English Mermaid & Ranger 10. Testing of Installation With the base plate firmly installed, place the mast back onto the base plate studs and fully tighten down the four nuts. IMPORTANT: It is strongly recommended the installation of the base plate is load tested before the Mermaid is put into use.
  • Page 14 (available optionally) at the bottom of the mast. The spacers are 75mm in height and a maximum of 2 can be used, giving a maximum additional height of 150mm. Contact Joerns Healthcare Ltd for the supply of either of these items.
  • Page 15: Operating Instructions

    Oxford ® English Mermaid & Ranger 11. Operating Instructions WARNING Oxford patient lifts should only be operated by fully trained/competent care givers. Mermaid Model: The Mermaid range of bath lifts are designed to be simple and safe to use. Carefully follow these simple instructions to ensure trouble free operation.
  • Page 16: Safety Precautions

    The safety locking system has been designed to be very visible and very obvious in operation - double check the latches have engaged or disengaged correctly. NOTE: Joerns Healthcare Ltd recommend a few “dry runs” without the patient in place, to familiarise users with the operation of the transporter chair and bath lift.
  • Page 17: Taking Care Of Your Mermaid

    Oxford ® English Mermaid & Ranger 13. Taking Care of Your Mermaid Oxford recommends that your Mermaid bath hoist and associated accessories are cleaned thoroughly and regularly. When the hoist and/or accessories require cleaning, or if there is a suspicion of contamination, please follow the cleaning and/or disinfection procedures outlined below.
  • Page 18 Dry the brush and store ready for the next cleaning operation. PLEASE NOTE: As methods and good practises evolve over time, the instructions detailed above may differ from your own recommended guidelines. If in doubt, please contact your local authorised Oxford dealer or Joerns Healthcare directly.
  • Page 19 Oxford ® English Mermaid & Ranger Cleaning the Lap Strap: The lap strap can be easily cleaned, rinsed and re-applied to the seat. Follow all precautions and warnings highlighted in the earlier sections of this manual. The lap strap material can be cleaned using hard surface disinfectant wipes that are supplied impregnated with a 70% v/v solution of Isopropyl Alcohol.
  • Page 20: Charging Instructions (Electric Variants)

    The socket is labelled POWER/CHARGING POINT. The battery pack on the Oxford Mermaid can be removed from the lift and charged independently. An additional battery pack can be supplied, if required, so that one pack can be on charge at all times.
  • Page 21 Oxford ® English Mermaid & Ranger The charging of Oxford electric lift is simple and straightforward, but it is important to follow the charging instructions closely. Please pay particular attention to the following points, it will help you avoid problems with discharged batteries. •...
  • Page 22: Daily Check List

    Service Dealer. Daily Check List: WARNING Joerns Healthcare strongly recommends the following checks are carried out on a daily basis and before using the lift. Failure to carry out these checks may result in injury to the patient and/or care-giver.
  • Page 23: Maintenance Schedule

    English Mermaid & Ranger 16. Maintenance Schedule Joerns Healthcare Ltd recommend the following tasks are carried out by authorised service dealers only. FLOOR FIXING: Check the base plate fixing is sound and secure. Follow the test routine as detailed in the installation instructions. Wooden floors require inspection at more frequent intervals.
  • Page 24 Oxford ® English Mermaid & Ranger Additional Tasks for Electric Variants Only: HAND CONTROL: Check the correct operation of the RAISE and LOWER buttons on the hand control. Take the seat to the lowest position and confirm the operation of the bottom stop. Check the seat does not hit the bottom of the bath.
  • Page 25: Technical Specifications

    Oxford ® English Mermaid & Ranger 17. Technical Specifications Manual Electric Safe Working Load (SWL) ..............125kgs ....125kgs Highest position from base of seat .............740mm ..... 715mm Lowest position from base of seat ............140mm ..... 140mm Seat travel ..................485mm ..... 485mm Width of seat............
  • Page 26 Oxford ® English Mermaid & Ranger Electrical Specification: Batteries ..........2 x 12 VDC Rechargeable, sealed, lead acid gel Capacity........... 3.2 Ampere/hours Charger rated input........110 - 230Vac 50/60 Hz Charger rated output ....... 27.4/29.0 VDC@0.8A Fuse - Lift..........25A Fast Blow 1/4” x 1 1/4” Electric Shock Protection Charger - Class II Double Insulated Lift - Internal Power Source...
  • Page 27 Oxford ® English Mermaid & Ranger KEY SYMBOLS: The following symbols are used on the charger, control unit and battery: This product is a Medical Device in accordance with EU Medical Device Regulation 2017/745. Class 2 equipment. The disposal of batteries should not be mixed with general household waste. Batteries should be disposed of in accordance with local or national regulations.
  • Page 28: Warranty

    If you are in any doubt as to where your lift was purchased, Joerns Healthcare can trace the supplier if you quote the serial number of the lift.