Aybey Elektronik UPSLIFT User Manual

Aybey Elektronik UPSLIFT User Manual

Emergency power supply for lifts

Advertisement

Quick Links

UPSLIFT
EMERGENCY POWER SUPPLY FOR LIFTS
USER MANUAL
Version: 1.2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UPSLIFT and is the answer not in the manual?

Questions and answers

Summary of Contents for Aybey Elektronik UPSLIFT

  • Page 1 UPSLIFT EMERGENCY POWER SUPPLY FOR LIFTS USER MANUAL Version: 1.2...
  • Page 2 It does not supply any energy to the motor. Therefore, in a system where UPSLIFT is used as emergency power supply then the motor should be fed either by batteries or by another UPS. UPSLIFT makes use of five 12V dry batteries. It can be used in all kinds of controllers.
  • Page 3 3- TECHNICAL SPECIFICATIONS 3.1 General Specifications Table 3.1 Technical Specification Nominal Output Voltage 220V AC Max. Output Current Max. Output Power 1800VA DC Input Voltage 60V DC Batteries (Number x Voltage) 5 x 12V DC Battery Capacity Minimum 4 Ah (See chapter 4 for selection) Cutdown Battery Voltage Max.
  • Page 4 3.2 Physical Dimensions Figure 3.2 Mounting Dimensions Figure 3.1: Mechanical Dimensions Table 3.2 Mechanical Dimensions [mm] Model UL180 Table 3.3 Mounting Dimensions [mm] Model Ø UL180...
  • Page 5 4- BATTERY AND WIRE SELECTION GUIDE There should be 5 x 12V batteries as energy source for UPSLIFT. Battery charge capacities should be minimum 4 Ah. However when the batteries are used at the same time as the energy source by the traction motor, then the current taken from the batteries by the motor should be taken into account for selecting the charge capacity of the batteries.
  • Page 6 5- ELECTRICAL CONNECTIONS Internal blocks and terminal connections of UPSLIFT are shown in Figure 5.1 and Table 5.1. Figure 5.1 UPSLIFT Electrical Connections Table 5.1 UPSLIFT Terminals Terminal Used For Comments Input Phase Terminal Input Neutral Terminal Line Voltage Earth Connection...
  • Page 7 UPSLIFT will stay alive for one hour after a power breakdown. At the end of this period, it enters sleep mode to protect the batteries from excessive discharging. However the device can be awaken at any time when the RESET input is activated manually provided and the main switch is in ON position.
  • Page 8 7- TROUBLESHOOTING Table 7.1 shows some comments about common reported problems. Table 7.1: Possible Errors and Solutions NO PROBLEM COMMENTS  Check MS (main switch) switch. It must be ON.  Check if the batteries are connected correctly.  Check 5V LED, it should be blinking. If not there may be a There is no output voltage fault in electronic board.