10. SERVICE INSPECTION 1.0 INTRODUCTION Thank you for choosing the Smirthwaite Easi Change shower stretcher fixed height. The stretcher has been designed to fit into a room where space is at a premium, and provides a durable and economic solution to showering requirements.
2.0 ILLUSTRATION OF YOUR SHOWER STRETCHER A. Durable non-rip vinyl B. Stainless steel powder coated frame C. Wall mount frame cover D. Enclosed dampener strut E. Safety guard rail (Optional accessory) Shower Stretcher Fixed Height...
Smirthwaite Ltd. Failure to follow these instructions will not only invalidate the guarantee but could make the product dangerous to use. Smirthwaite Ltd will not accept liability for any injury or damage incurred through such malpractices.
5.0 SURVEYING AND INSTALLATION STOP! If in any doubt, ALWAYS seek ADVICE. Always turn screws clockwise to tighten or anti-clockwise to loosen. 5.1 SURVEYING PROCEDURES • Shower stretchers are often installed in small rooms with limited space. In such circumstances it is vitally important to take accurate measurements of the whole room in question, and make a plan to scale if possible.
Page 7
5.3 INSTALLATION PROCEDURE • Carefully unpack the shower stretcher and lay all parts on to the floor. • Check all component packs are present • Check all components for damage that may have occurred during transit Wall Bracket Assembly Qty: 1 Wall Bracket Cover Qty: 1 Stretcher Frame...
Page 8
5.3 INSTALLATION PROCEDURE (Cont) STOP! Due to the size of this product, it is recommended installation is undertaken by two persons • Store the stretcher frame, back cover and backing board (if ordered) somewhere safe. • Position the wall bracket assembly level on the desired wall at an appropriate height, ensuring you have checked for clearances as described before.
Page 9
5.3 INSTALLATION PROCEDURE (Cont) • Offer up the stretcher frame to the wall bracket assembly, fixing into place using 3 screws per side as shown below (M10 x 20mm screws, total quantity 6) • Ensure the screw fixings are tight FIXINGS 6 x M10 x 20mm •...
Page 10
5.3 INSTALLATION PROCEDURE (Cont) • To complete installation, it is necessary to fit the wall bracket cover to the wall bracket assembly. • Offer up the cover to the wall bracket assembly and secure in place with 4 push fixings (D) as shown below 5.4 SHOWER STRETCHER HEAD REST ACCESSORY If the customer has specified on order a head rest accessory, this will be fitted to the shower stretcher at the time of manufacture at the factory.
6.0 HOW TO USE YOUR SHOWER STRETCHER 6.1 GENERAL USE AND STORAGE • Where space is at a premium, the stretcher should always be stored vertically when not in use. • By rotating the stretcher vertically, it will automatically lock into the stored position.
Page 12
6.3 SAFETY GUARD RAIL ACCESSORY • To operate the guard rail rotate it upwards to vertical position. • When in the upright position, lift the guard rail to engage the locking pins (G) • To lower the guard rail, slightly lift the item to disengage the locking pins (G) •...
Check that the shower stretcher can be securely stored in the vertical position, and that the plunger locking pin engages. 7.2 SERVICE INTERVAL This product should be serviced every year. Servicing must only be undertaken by a Smirthwaite service engineer, or by a Smirthwaite trained representative. Shower Stretcher Fixed Height...
Page 14
Product service life has been determined based upon the design complexity of product, and the anticipated exposure to normal use. Good practice dictates all Smirthwaite products have been designed and manufactured to high levels of safety and quality, and will meet requirements of normal use when maintained in line with our servicing recommendations.
Page 15
• We recommend an inspection/service by a Smirthwaite Service Engineer (or Smirthwaite trained engineer) whenever a significant change is made to product configuration to ensure the product is safe to use.
Page 16
DO NOT fit parts or accessories of other manufacturers to this product unless authorized to do so in writing by Smirthwaite Ltd. Any servicing or repairs required must be carried out by Smirthwaite Ltd (or a Smirthwaite trained engineer). If you believe this product to be faulty – DO NOT USE – Contact Smirthwaite Ltd on T: +44 (0) 1626 835552 If in any doubt, ALWAYS seek ADVICE.
8.0 WARRANTY & SERVICE Smirthwaite Ltd warrants the products detailed on your order to be free from defects in materials and workmanship for a period of 2 years from date of delivery. If a fault develops during the period, please call Customer Services by email or telephone 01626 835552 who will advise you on the best course of action.
Should you have any suggestions or comments please send them to our product design department at: info@smirthwaite.co.uk Smirthwaite Ltd reserve the right to change the specification or material without prior notice. For catalogues, help and further information on our products please contact us at:...
10.0 SERVICE INSPECTION 10.1 Product Information Model: Size: Date of Manufacture: Serial Number: Final Inspection: 10.2 Service & inspection record form: Date Procedure Service Personnel Shower Stretcher Fixed Height...