Advertisement

Quick Links

Table of contents

1.
Function .............................................................................................. 2
2.
Technical Data ..................................................................................... 3
2.2
The controller ............................................................................. 3
2.2.1
Cycle - pause in minutes ........................................................... 3
2.2.2
Splash quantity ........................................................................ 3
2.2.3
Programme and test switch ....................................................... 4
2.2.4
Indications of the controller ....................................................... 4
2.2.5
Main switch ............................................................................. 5
2.2.6
Pre-indication of the splash ....................................................... 5
2.2.7
Adjustment of the dosing .......................................................... 5
3.
The dosing pump ................................................................................. 6
3.1
Changing the hose set ................................................................. 6
3.2
Dosing valve ............................................................................... 7
3.3
Fragrance canister ....................................................................... 7
4
Installation / Taking the unit into operation ............................................. 7
4.1
Installation ................................................................................. 7
4.2
Electrical connection .................................................................... 8
4.3
Splash sprinkler .......................................................................... 9
5
Maintenance ...................................................................................... 10
5.1
Changing the canister ................................................................ 10
5.3
Checking the dosing valve .......................................................... 10
5.4
Cleaning the splash sprinkler ...................................................... 10
5.5
Cleaning the protection filter ...................................................... 10
5.6
Checking the press switch .......................................................... 11
5.7
Trouble shooting ....................................................................... 11
6
Wiring diagramme .............................................................................. 12
6.
Spare parts list .................................................................................. 13
6.1
Pump and controller ..................................................................... 13
7.2
Water part................................................................................... 14
operation manual SAUNA-VII (07/12)
SAUNA- Plus VII
page 1 of 14
page

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SAUNA-Plus VII and is the answer not in the manual?

Questions and answers

Summary of Contents for WDT SAUNA-Plus VII

  • Page 1: Table Of Contents

    operation manual SAUNA-VII (07/12) page 1 of 14 SAUNA- Plus VII Table of contents page Function ....................2 Technical Data ..................3 The controller ................3 2.2.1 Cycle - pause in minutes ............3 2.2.2 Splash quantity ................ 3 2.2.3 Programme and test switch ............
  • Page 2: Function

    operation manual SAUNA-VII (07/12) page 2 of 14 Function The splash automatic SAUNA-Plus VI doses the splash full automatically to the sauna oven. The dosing cycle, the intensity of the splash (quantity of water) and the arome-intensity (quantity of fragrance) are adjusted individual by 3 rotary knobs.
  • Page 3: Technical Data

    operation manual SAUNA-VII (07/12) page 3 of 14 Technical Data The unit consists of: water connection ½“ female thread (app. 150l per hour) solenoid valve ½“ peristaltic pump 12-24VDC for fragrance controller with connector for ore-indiation of the splash 230VAC connector for push-button or external start device voltage supply 230VAC 1,25A splash sprinkler 3/8“...
  • Page 4: Programme And Test Switch

    operation manual SAUNA-VII (07/12) page 4 of 14 2.2.3 Programme and test switch The programme and test switch is to choose the operation programmes and to test all functions of the SAUNA-Plus-VII: operation: controlled internally with cycle and splash quantity operation with push-button: start of the splash by external push- button and adjustment „splash quantity“...
  • Page 5: Main Switch

    operation manual SAUNA-VII (07/12) page 5 of 14 2.2.5 Main switch You find the illuminated main switch (for switching the unit on & off) on the left side of the controller housing. 2.2.6 Pre-indication of the splash A pilot lamp that indicates the coming splash can be connected to the controller.
  • Page 6: The Dosing Pump

    operation manual SAUNA-VII (07/12) page 6 of 14 Attention! If you switch the unit on the first splash always starts with a delay of 30 minutes (set up ex works). This switch-on delay can be switched-off manually (see wiring diagramme). The fragrance dosing is only unlocked if water flows through the unit.
  • Page 7: Dosing Valve

    4x1 mm – male thread 3/8“. Fragrance canister The SAUNA-Plus VII is delivered to be mounted on the wall, the fragrance canister (volume 1.5 l) is pre-mounted at the mounting plate. Installation / Taking the unit into operation...
  • Page 8: Electrical Connection

    operation manual SAUNA-VII (07/12) page 8 of 14 The dosing unit SAUNA PLUS VI is delivered in a state ready for operation. It has to be mounted on place that is accessable easily and a bit higher than the oven. The installed security device according to DIN 1988 is useable for non-toxical fragrances for sauna splashs.
  • Page 9: Splash Sprinkler

    operation manual SAUNA-VII (07/12) page 9 of 14 Splash sprinkler The scope of delivery includes a splash sprinkler made of stainless steel (16) to distribute the water drops over the stones of the oven. Connection for splash tubing is 3/8” female thread. Longer splash tubings are deliverable on demand.
  • Page 10: Maintenance

    operation manual SAUNA-VII (07/12) page 10 of 14 Maintenance Changing the canister Release the canister lid from the empty canister and refill it. Make sure not to overfill it. Checking/ changing the dosing hose (see 3.1) The hose set of the pump is exposed to a mechanical anch chemical wear. For this reason the pump hose has always to be checked when the fragrance is refilled.
  • Page 11: Checking The Press Switch

    operation manual SAUNA-VII (07/12) page 11 of 14 Checking the press switch Adjust the programme switch to T-pressure. The “splash indication” LED shines for five seconds with a delay of 2 seconds. Afterwards, the solenoid valve is switched on and water flows to the oven. The LED “splash” shines. After the lapse of the test programme, the LED “operation”...
  • Page 12: Wiring Diagramme

    operation manual SAUNA-VII (07/12) page 12 of 14 Open all ball valves. Clean filter (central filter in technical room?) Test every single function/ component with the test switch. Wiring diagramme...
  • Page 13: Spare Parts List

    operation manual SAUNA-VII (07/12) page 13 of 14 Spare parts list Pump and controller The peristaltic pumo Sa transparent pump cover retaining washer holder roller pump hosuing felt sealing diaphragm motor mounting screw electrical connection Identification Article no. Fragrance pump lid for pump housing........….
  • Page 14: Water Part

    operation manual SAUNA-VII (07/12) page 14 of 14 Water part ball valve ½“ filter ½“ messing protection group solenoid valve sipon pipe PE 4x1 lid for canister canister pressure switch with cap tube VA 2 T-Stück dosing valve 3/8“ für fragrance flexible pressure tubing PTFE 4x1 Identification Article no.