Blower Installation Instructions
Model: BLOTMC
WARNING:
person should service and repair this firebox. A qualified service person must connect
and disconnect the firebox to/from the gas supply. Follow all local codes.
Before You Start
NOTE: This instruction sheet is ONLY for models listed
below. Carefully inspect the contents for shipping dam-
age. If any parts are missing or damaged, immediately
inform the dealer from whom you purchased the blower.
Models:
GCUF,
MCUF,
LCUF32/36/42CR-B
WARNING
Electrical Grounding Instructions:
This appliance is equipped with a three-prong (ground-
ing) plug for your protection against shock hazard and
should be plugged directly into a properly grounded
three prong receptacle.
Kit Contents:
(1) Blower Assembly w/ Velcro Strips
(1) Thermostat Sensor w/ Hi-temp Wire
(1) Speed Control
(1) Speed Control Bracket
(1) Air Shield
(1) Wire Tie
(1) Hardware Package
(1) Instruction Sheet
Tools Required:
Short Handle Phillips Screwdriver
Small Jeweler's Style Screwdriver
Pliers or 1/4" Wrench
Wiring Instructions
1. Before installing the blower, wire the receptacle into an
electrical circuit. This should be done before framing
the fireplace. Wire with minimum 60° C wire in accor-
dance with prevailing codes.
2. Remove the external junction box cover by removing
the screw from the left side of the outside firebox wall.
Junction box was installed at the factory.
3. The junction box cover has a factory installed "romex"
style strain relief connector. After connecting the wires,
route the wire leads through this connector. Refer to
the wiring diagram in Figure 1.
Note: Figure 2 shows an alternative wiring method if a
remotely located switch is desired.
Monessen • BLOTMC Installation Manual • 93D0005 • Rev H • 01/2020
Turn appliance OFF and allow to cool before servicing. Only a qualified service
BUF36/42,
VFF32/36,
CAUTION! Electrical connections should only be performed
by a qualified licensed electrician. Main power supply must
be turned off before connecting fans to the main electrical
power supply or performing service.
The BLOTMC blower is designed for use with vent
free fireplaces manufactured by Hearth & Home
Technologies only.
IMPORTANT: Always check local building codes. This in-
stallation must comply with local regulations as well as
the National Electric Code.
Junction Box
Figure 1 - Junction Box Wiring Diagram
FP1912
JUMPER
Junction box wiring
BLK
8/08
WHT
POWER CORD
WHT
MINIMUM 14
JUNCTION BOX
BLK
Figure 2 - Wall Switch Wiring Diagram
WARNING
Factory Supplied
Not Supplied
BLOWER
WHT
WHT
2
-
BLK
BLK
WALL SWITCH
OR RHEOSTAT
120V AC
60Hz
110V SUPPLY

Advertisement

loading
Need help?

Need help?

Do you have a question about the BLOTMC and is the answer not in the manual?

Questions and answers

Summary of Contents for Monessen Hearth BLOTMC

  • Page 1 Figure 1. OR RHEOSTAT Note: Figure 2 shows an alternative wiring method if a Figure 2 - Wall Switch Wiring Diagram remotely located switch is desired. Monessen • BLOTMC Installation Manual • 93D0005 • Rev H • 01/2020...
  • Page 2: Blower Instructions

    The blower should be centered with the rear blower discharge vent facing up and flat against the firebox back wall and floor. Figure 5 Discharge Vent Velcro Strips Velcro Firebox Strips Figure 5 Monessen • BLOTMC Installation Manual • 93D0005 • Rev H • 01/2020...
  • Page 3 Blower Bracket Blower in Place Flange Discharge Vent Figure 6 Speed Control Blower Switch Bracket Speed Control Knob Figure 7 - Speed Control Secured to Bracket Figure 8 Monessen • BLOTMC Installation Manual • 93D0005 • Rev H • 01/2020...
  • Page 4 BUF36/R VF0048744/ BUF42/R VF0048745 and earlier must drill two (2) holes to attach the sensor. See Figure KT1111 attach thermal senso 8.78 0.94 2.00 screw holes Figure 10 Monessen • BLOTMC Installation Manual • 93D0005 • Rev H • 01/2020...
  • Page 5 Figure 14 It is important to arrange the blower wire harness so the wires can not come in contact with the blower fan blades. White Dial Figure 15 Monessen • BLOTMC Installation Manual • 93D0005 • Rev H • 01/2020...
  • Page 6 2. Remove Blower Switch Bracket. See Figure 7. 3. Attach the Variable Speed Control to the control panel with the 2 screws previously removed. See Figure 17. 4. Reinstall the knob. Monessen • BLOTMC Installation Manual • 93D0005 • Rev H • 01/2020...
  • Page 7 7. Pull the wires toward the back of the unit toward the rear access panel. 120VAC Receptacle Junction Extension Wire WHITE WHITE GREEN BLACK BLACK BLACK WHITE BLACK BLACK Speed Control Figure 21 Monessen • BLOTMC Installation Manual • 93D0005 • Rev H • 01/2020...
  • Page 8 Refer to burner / log set instruc- tions for correct placement. Monessen, a brand of Hearth & Home Technologies 7571 215th Street West, Lakeville, MN 50044 www.monessenhearth.com Monessen • BLOTMC Installation Manual • 93D0005 • Rev H • 01/2020...