Vents KAM User Manual

Vents KAM User Manual

Chimney centrifugal fan

Advertisement

USER'S MANUAL
KAM
Chimney centrifugal fan

Advertisement

Table of Contents
loading

Summary of Contents for Vents KAM

  • Page 1 USER'S MANUAL Chimney centrifugal fan...
  • Page 2: Table Of Contents

    Warranty card ....................................24 This user’s manual is a main operating document intended for technical, maintenance, and operating staff. The manual contains information about purpose, technical details, operating principle, design, and installation of the KAM unit and all its modifications.
  • Page 3: Safety Requirements

    • Do not use the unit in a hazardous or explosive environment containing spirits, gasoline, insecticides, etc. • Do not close or block the intake or extract vents in order to ensure the efficient air flow. • Do not sit on the unit and do not put objects on it.
  • Page 4 This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Page 5: Purpose

    ACCESS BY UNATTENDED CHILDREN. The KAM electric centrifugal fan in a metal casing with an impeller diameter of 146 to 158 mm, hereinafter referred to as the fan, is a part of the fireplace heating system and is designed to transport clean air with a temperature of up to +150 °C from the space around the fireplace to various rooms through the ductwork, which increases the efficiency of the fireplace with the ventilation system of the building.
  • Page 6: Designation Key

    The duct system must be free of plastic parts DESIGNATION KEY КАМ 150 Eco Bypass T1 ___/___ Designation example: Model KAM – chimney fan Connection spigot diameter [mm] Motor characteristics _ – asynchronous with an additional impeller for blowing and cooling Eco – with an external rotor EcoDuo –...
  • Page 7: Technical Data

    TECHNICAL DATA KAM, KAM ECO MAX, KAM ECO, KAM ECODUO 1 – fan casing 2 – inlet flange 3 – terminal box 4 – outlet flange 5 – temperature controller 6 – impeller 7 – speed switch (for EcoDuo model) KAM ECO BYPASS 1 –...
  • Page 8 8 – temperature control damper 9 – reverse air duct flange 10 – filter element 11 – latches KAM FAN WITH KFK AND GFK DAMPERS 1 – KAM fan 2 – outlet flange 3 – terminal box 4 – temperature controller 5 –...
  • Page 9: Operating Logic

    D, mm H, mm h, mm KAM 125 KAM 140 KAM 150 KAM 160 KAM 125 Eco Bypass KAM 140 Eco Bypass KAM 150 Eco Bypass KAM 160 Eco Bypass KAM 150 Eco max KAM 125 Eco/EcoDuo KAM 140 Eco/EcoDuo...
  • Page 10 KAM, KAM ECO MAX, KAM ECO, KAM ECODUO Ó Ó Ó Ó KAM WITH AN FFK FILTER Ó Ó Ó Ó KAM ECO BYPASS Ó Ó Ó Ó www.ventilation-system.com...
  • Page 11 Ó Ó KAM FAN WITH A KFK DAMPER Ó Ó Ó Ó www.ventilation-system.com...
  • Page 12 KAM FAN WITH KFK AND GFK DAMPERS (BYPASS SYSTEM) Ó Ó Ó Ó EXAMPLE OF INSTALLATION AND OPERATION OF FANS WITH AN FFK FILTER AND A KFK DAMPER Reverse air duct: 1. Hot air removed by the temperature control damper.
  • Page 13: Mounting And Set-Up

    MOUNTING AND SET-UP BEFORE MOUNTING MAKE SURE THE CASING DOES NOT CONTAIN ANY FOREIGN OBJECTS (E.G. FOIL, PAPER). WHILE INSTALLING THE UNIT ENSURE CONVENIENT ACCESS FOR SUBSEQUENT MAINTENANCE AND REPAIR. After unpacking the fan make sure of no damages in the power supply line and no cuts and crack in the cable insulation, check the fan casing for no hollows and other distortions.
  • Page 14 POSSIBLE OPTIONS OF INSTALLING THE FAN AND CONNECTING IT INTO THE SYSTEM Attic. One-storey house. Attic. Two-storey house. Basement – ground floor. The fan can also be installed in a garage, bathroom, etc. FIXING FLEXIBLE AIR DUCTS TO CONNECTING ELEMENTS Slide out about 5 cm of the heat and sound insulation layer and the external contour of the duct.
  • Page 15 It is most preferable to use Y-joints instead of T-joints. This will reduce the air resistance of the duct system. During installation, the air ducts should be straightened and stretched as much as possible. Do not allow duct deflection. Reduce the number of turns, this will reduce the air resistance of the duct system.
  • Page 16: Connection To Power Mains

    The recommended rated current of the automatic circuit breaker is 1.6 А. The KAM, KAM Eco, KAM EcoDuo fans have a built-in thermostat relay, which closes the fan power circuit when the set temperature of the hot air in the fireplace is reached (the fan automatically turns on and the warm air enters the room).
  • Page 17 ASYNCHRONOUS ELECTRIC MOTOR STARTING METHODS There are several methods for starting asynchronous squirrel-cage electric motors. The most common methods are: direct-on-line (DOL), with a soft starter (SS) or with a frequency converter (FC). Direct-on-line starting In case of direct-on-line starting (i.e. by connecting the motor to the electric mains with a simple line contactor), the motor starting time significantly increases due to high inertia of the impeller, which, in turn, results in high in-rush starting currents in the circuit.
  • Page 18: Commissioning

    Let us review three variations of a heavy start: 1. The feed line performance is barely sufficient or insufficient to maintain the induced current. Typical symptoms: Upon starting the circuit breakers at the system input are tripped; the lights, certain relays and contactors go off, and the supply generator shuts down.
  • Page 19: Technical Maintenance

    Avoid liquid dripping on the motor and the temperature controller. In case of any problems related to the fan switching or operation, it is recommended to use a troubleshooting table to eliminate the faults. KAM, KAM ECO MAX, KAM ECO, KAM ECODUO...
  • Page 20 KAM ECO BYPASS KAM WITH AN FFK FILTER KAM FAN WITH A KFK DAMPER KAM FAN WITH KFK AND GFK DAMPERS www.ventilation-system.com...
  • Page 21 POSSIBLE MALFUNCTIONS AND THEIR ELIMINATION Problem Possible reasons Elimination The fan will not start. No power supply. Check the mains switch. Check the electrical connections against the wiring diagram. Jammed motor. Carefully check the fan impeller for possible seizure and eliminate it, if necessary.
  • Page 22: Storage And Transportation Regulations

    The fan supplies less air than Wrong calculation of the ventilation network and Re-calculate the network parameters and select a expected. wrong selection of the fan. matching fan. The network resistance exceeds the design Re-arrange the ventilation network to decrease its calculations.
  • Page 23: Manufacturer's Warranty

    MANUFACTURER’S WARRANTY The product is in compliance with EU norms and standards on low voltage guidelines and electromagnetic compatibility. We hereby declare that the product complies with the provisions of Electromagnetic Compatibility (EMC) Directive 2014/30/EU of the European Parliament and of the Council, Low Voltage Directive (LVD) 2014/35/EU of the European Parliament and of the Council and CE-marking Council Directive 93/68/EEC.
  • Page 24: Certificate Of Acceptance

    CERTIFICATE OF ACCEPTANCE Unit Type Chimney centrifugal fan Model KAM___________________________________ Serial Number Manufacture Date Quality Inspector’s Stamp SELLER INFORMATION Seller Address Phone Number E-mail Purchase Date This is to certify acceptance of the complete unit delivery with the user’s manual. The warranty terms are acknowledged and accepted.
  • Page 25 www.ventilation-system.com...
  • Page 26 www.ventilation-system.com...
  • Page 27 www.ventilation-system.com...
  • Page 28 V15EN-08...